Seismic Response of Reinforced-Concrete One-Storey Precast Industrial Buildings with Horizontal Cladding Panels

被引:1
|
作者
Gams, Matija [1 ]
Staresinic, Gabrijela [2 ]
Isakovic, Tatjana [1 ]
机构
[1] Univ Ljubljana, Fac Civil & Geodet Engn, Jamova 2, Ljubljana 1000, Slovenia
[2] Godina Gradbenistvo Druge Storitve Doo, OIC Hrpelje 22, Hrpelje 6240, Slovenia
关键词
RC precast structures; horizontal RC cladding; sensitivity analysis; cladding connections; GROUND-MOTION; PERFORMANCE; CONNECTIONS; BEHAVIOR;
D O I
10.3390/buildings13102519
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An extensive parametric study of the seismic response of one-storey precast buildings with horizontal cladding panels frequently used in Central Europe was conducted to analyse the panels' influence on the overall response of buildings and to find out if the panels can be considered non-structural elements when they are attached to the main building with the connections typically used in practice in Central Europe. The studied structural system consisted of reinforced concrete columns and beams connected by dowels. Horizontal cladding panels were attached to columns using one of the most frequently used isostatic fastening systems. The top connections provided out-of-plane stability, and the bottom connections supported the panel in the vertical direction. The parametric study was preceded by extensive experimental research, including cyclic tests on connections and full-scale shaking table tests of whole buildings. The results of experiments were used to reveal the basic response mechanisms of panels and connections and to develop, validate and calibrate numerical models employed in the parametric study presented herein. Fifteen generalised structures with different masses and heights were subjected to 30 accelerograms with two peak ground acceleration (PGA) intensities of 0.3 g and 0.5 g, corresponding to significant damage and near-collapse limit states. The effects of the construction imperfections in connections, the silicon sealant panel-to-panel connections and different types of connections of the bottom panel to the foundation were analysed. The crucial parameter influencing the response was the displacement capacity of the connections, which was considerably affected by the construction imperfections and, consequently, difficult to estimate. It has been observed that in some buildings, particularly in shorter structures with smaller mass, cladding panels can have a somewhat more notable influence on the overall response. However, in general, when the considered types of connections are used, the panels can be considered as non-structural elements, which do not importantly influence the response of the main building. Owing to structural imperfections and relatively short available gaps, the failure of the considered top connections and falling of the panels is very likely in the high seismicity regions. In the most adverse cases, it can occur even in the moderate seismicity regions.
引用
收藏
页数:26
相关论文
共 50 条
  • [31] Seismic Response of Reinforced-Concrete Masonry Shear-Wall Components and Systems: State of the Art
    El-Dakhakhni, Wael
    Ashour, Ahmed
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (09)
  • [32] Seismic and collapse performance of a hybrid structure comprising steel frame with precast concrete shear walls and cladding panels
    Wang, Hanqin
    Jiang, Qing
    Chong, Xun
    Feng, Yulong
    Huang, Junqi
    EARTHQUAKE ENGINEERING AND RESILIENCE, 2022, 1 (04): : 440 - 453
  • [33] Seismic behaviour of precast sandwich wall panels of steel fibre reinforced concrete layers and fibre reinforced polymer connectors
    Lameiras, Rodrigo
    Barros, Joaquim A. O.
    Valente, Isabel B.
    Poletti, Elisa
    Azevedo, Matilde
    Azenha, Miguel
    ENGINEERING STRUCTURES, 2021, 237
  • [34] Experimental investigation of the response of precast concrete cladding panels with integrated connections under monotonic and cyclic loading
    Psycharis, Ioannis N.
    Kalyviotis, Loannis M.
    Mouzakis, Harris P.
    ENGINEERING STRUCTURES, 2018, 159 : 75 - 88
  • [35] Performance-based assessment of slender reinforced concrete columns typical of precast industrial buildings
    Deyanova, M.
    Bellotti, D.
    Nascimbene, R.
    Pampanin, S.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2023, 21 (01) : 433 - 471
  • [36] Seismic performance of precast steel fiber reinforced lightweight aggregate concrete shear walls assembled with a socket horizontal joint
    Deng, Lianchao
    Yang, Yabin
    Yang, Junna
    Lv, Feiyang
    Zhao, Mingshuang
    Zhao, Shunbo
    JOURNAL OF BUILDING ENGINEERING, 2024, 91
  • [37] Cyclic Response of Precast High-Performance Fiber-Reinforced Concrete Infill Panels
    Olsen, E. C.
    Billington, S. L.
    ACI STRUCTURAL JOURNAL, 2011, 108 (01) : 51 - 60
  • [38] A design method for seismic retrofit of reinforced concrete frame buildings using aluminum shear panels
    Ferraioli, Massimiliano
    Lavino, Angelo
    De Matteis, Gianfranco
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2023, 23 (02)
  • [39] Evaluation of the contribution of masonry infill panels on the seismic behaviour of two existing reinforced concrete buildings
    Milheiro, Joo
    Rodrigues, Hugo
    Arede, Antonio
    KSCE JOURNAL OF CIVIL ENGINEERING, 2016, 20 (04) : 1365 - 1374
  • [40] Seismic Reliability Maps of Code-Compliant Italian Reinforced-Concrete Bare and Infilled Frame Buildings
    Feltrin, Gianantonio
    Hofer, Lorenzo
    Zanini, Mariano Angelo
    BUILDINGS, 2024, 14 (07)