Copper nanoparticles encapsulated in reduced graphene oxide electrode (CuxrGO1-x) for the electrochemical quantification of metformin in water

被引:11
|
作者
Shih, Yu-Jen [1 ,2 ]
Su, Yu-Qiao [1 ]
Chen, Wei-Hsiang [1 ]
Lin, Sheng-Kai [1 ]
He, Yi-Chun [1 ]
Huang, Chin-Pao [3 ]
机构
[1] Natl Sun Yat Sen Univ, Inst Environm Engn, Kaohsiung, Taiwan
[2] Natl Sun Yat Sen Univ, Ctr Emerging Contaminants Res, Kaohsiung, Taiwan
[3] Univ Delaware, Dept Civil & Environm Engn, Newark, DE 19716 USA
关键词
Reduced graphene oxide; Differential pulse voltammetry; Pharmaceutical; Biguanide; Electrochemical sensor; CARBON-PASTE ELECTRODE; N; N-DIMETHYLBIGUANIDE COMPLEXES; VOLTAMMETRIC DETERMINATION; DRUG METFORMIN; WASTE-WATER; PRODUCTS; SENSOR; PHARMACEUTICALS; TRANSFORMATION; NANOCOMPOSITE;
D O I
10.1016/j.cej.2023.144676
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Electrochemical oxidation of anti-diabetic metformin (MTF) drug was studied on glassy carbon electrode (GCE) prepared by electroplating of copper nanoparticles (Cu NPs) on reduced graphene oxide (rGO). Results showed that the crystallite size and dispersity of Cu NPs on rGO sheets controlled the redox characteristics of CuxrGO1-x. Voltammetry revealed faradaic Cu(II)/Cu(I) redox current at specific anodic potentials as a function of MTF concentration due to biguanide Cu(II)-MTF complexation. rGO, an electron promoter, improved the current density while lowering the overpotential of MTF oxidation. Both the electrochemical surface area (ECSA) and reaction sensitivity were optimal at the Cu to rGO mass ratio of 7:3 for MTF detection. The electrode also exhibited high degree of reproducibility, selectivity, and recovery in 0.1 M of phosphate buffer solution and pH 12. There was a high degree of linearity between anodic current and MTF concentration in the range of 2 to 70 & mu;M at a slope of 1.375 & mu;A/& mu;M and detection limit of 0.09 & mu;M by differential pulse voltammetry (DPV) technique.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Electrochemical DNA biosensor based on gold nanoparticles and partially reduced graphene oxide modified electrode for the detection of Listeria monocytogenes hly gene sequence
    Niu, Xueliang
    Zheng, Wen
    Yin, Chunxiao
    Weng, Wenju
    Li, Guangjiu
    Sun, Wei
    Men, Yongling
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 806 : 116 - 122
  • [42] Protein-Aided Synthesis of Copper-Integrated Polyaniline Nanocomposite Encapsulated with Reduced Graphene Oxide for Highly Sensitive Electrochemical Detection of Dimetridazole in Real Samples
    Behera, Kartik
    Mutharani, Bhuvanenthiran
    Chang, Yen-Hsiang
    Kumari, Monika
    Chiu, Fang-Chyou
    POLYMERS, 2024, 16 (01)
  • [43] An ultrasensitive electrochemical sensor for quercetin based on 1-pyrenebutyrate functionalized reduced oxide graphene /mercapto-β-cyclodextrin /Au nanoparticles composite film
    Zhou, Zhidu
    Gu, Chunmeng
    Chen, Chao
    Zhao, Pengchen
    Xie, Yixi
    Fei, Junjie
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 288 : 88 - 95
  • [44] Optimized electrochemical synthesis of copper nanoparticles decorated reduced graphene oxide: Application for enzymeless determination of glucose in human blood
    Balasubramanian, Paramasivam
    Velmurugan, Murugan
    Chen, Shen-Ming
    Hwa, Kuo-Yuan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 807 : 128 - 136
  • [45] Ciprofloxacin Electrochemical Sensor Using Copper-Iron Mixed Metal Oxides Nanoparticles/Reduced Graphene Oxide Composite
    Chuiprasert, Jedsada
    Srinives, Sira
    Boontanon, Narin
    Polprasert, Chongrak
    Ramungul, Nudjarin
    Karawek, Apisit
    Boontanon, Suwanna Kitpati
    ACS OMEGA, 2024, 9 (22): : 23172 - 23183
  • [46] Utilizing a nanocomposite consisting of zinc ferrite, copper oxide, and gold nanoparticles in the fabrication of a metformin electrochemical sensor supported on a glassy carbon electrode
    Mohammad Hossein Ghanbari
    Parastoo Sharafi
    Sepideh Nayebossadr
    Zahra Norouzi
    Microchimica Acta, 2020, 187
  • [47] Electrochemical Determination of Hydrogen Peroxide Using a Glassy Carbon Electrode Modified with Three-Dimensional Copper Hydroxide Nanosupercages and Electrochemically Reduced Graphene Oxide
    Wang, Yong
    Cao, Wei
    Zhuang, Qianfen
    Ni, Yongnian
    ANALYTICAL LETTERS, 2018, 51 (15) : 2441 - 2456
  • [48] An electrochemical sensor based on gold nanoparticles-functionalized reduced graphene oxide screen printed electrode for the detection of pyocyanin biomarker in Pseudomonas aeruginosa infection
    Rashid, Jahwarhar Izuan Abdul
    Kannan, Vayithiswary
    Ahmad, Muhammad Hafiz
    Mon, Aye Aye
    Taufik, Safura
    Miskon, Azizi
    Ong, Keat Khim
    Yusof, Nor Azah
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2021, 120
  • [49] Ultrasensitive Determination of Dopamine and Uric Acid Based on Gold Nanoparticles@Carbon Dots/Electrochemical Reduced Graphene Oxide modified glassy carbon electrode
    Li, Muyi
    Yang, Xiang
    Liu, Wenjun
    Wang, Huixian
    Jiang, Hongmei
    Liu, Xiaoying
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (08): : 1 - 17
  • [50] SENSITIVE ELECTROCHEMICAL DETERMINATION OF ETHAMBUTOL IN PHARMACEUTICAL FORMULATION AND HUMAN URINE AT NICKEL NANOPARTICLES/ELECTROCHEMICALLY REDUCED GRAPHENE OXIDE MODIFIED ELECTRODE
    Mekassa, Brihanu
    Baker, Priscilla G. L.
    Chandravanshi, Bhagwan Singh
    Tessema, Merid
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2019, 33 (02) : 215 - 228