Device safety assessment of bronchoscopic microwave ablation of normal swine peripheral lung using robotic-assisted bronchoscopy

被引:5
作者
De Leon, Hector [1 ]
Royalty, Kevin [2 ]
Mingione, Louie [2 ]
Jaekel, David [3 ]
Periyasamy, Sarvesh [4 ]
Wilson, David [5 ]
Laeseke, Paul [4 ]
Stoffregen, William C. [6 ]
Muench, Tim [1 ]
Matonick, John P. [1 ]
Kaluza, Grzegorz L. [7 ]
Cipolla, Gustavo [1 ]
机构
[1] Ethicon Inc, 1000 US Highway 202, Raritan, NJ 08869 USA
[2] NeuWave Med Inc, Madison, WI USA
[3] Ethicon Inc, Redwood City, CA USA
[4] Univ Wisconsin, Sch Med & Publ Hlth, Madison, WI USA
[5] Schneck Med Ctr, Schneck Pulmonol, Seymour, IN USA
[6] Northstar Preclin & Pathol Serv LLC, Lake Elmo, MN USA
[7] CRF Skirball Ctr Innovat, Orangeburg, NY USA
关键词
Microwave ablation; robotic bronchoscopy; lung cancer; thermal ablation; animal model; bronchoscopic microwave ablation; computed tomography; RADIOFREQUENCY ABLATION; FORMALIN FIXATION; THERMAL ABLATION; PORCINE LUNG; CT FINDINGS; MODEL; SIZE; CANCER; MECHANISMS; PRINCIPLES;
D O I
10.1080/02656736.2023.2187743
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction The aim of this study was to assess the safety of bronchoscopic microwave ablation (MWA) of peripheral lung parenchyma using the NEUWAVE (TM) FLEX Microwave Ablation System, and robotic-assisted bronchoscopy (RAB) using the MONARCH (TM) Platform in a swine model. Methods Computed tomography (CT)-guided RAB MWA was performed in the peripheral lung parenchyma of 17 Yorkshire swine (40-50 kg) and procedural adverse events (AEs) documented. The acute group (day 0, n = 5) received 4 MWAs at 100 W for 1, 3, 5, and 10 min in 4 different lung lobes. Subacute and chronic groups (days 3 and 30, n = 6 each) received one MWA (100 W, 10 min) per animal. Results The study was completed without major procedural complications. No postprocedural AEs including death, pneumothorax, bronchopleural fistula, hemothorax, or pleural effusions were observed. No gross or histological findings suggestive of thromboembolism were found in any organ. One 3-Day and one 30-Day swine exhibited coughing that required no medication (minor AEs), and one 30-Day animal required antibiotic medication (major AE) for a suspected lower respiratory tract infection that subsided after two weeks. CT-based volumetric estimates of ablation zones in the acute group increased in an ablation time-dependent (1-10 min) manner, whereas macroscopy-based estimates showed an increasing trend in ablation zone size. Conclusion The NEUWAVE FLEX and MONARCH devices were safely used to perform single or multiple RAB MWAs. The preclinical procedural safety profile of RAB MWA supports clinical research of both devices to investigate efficacy in select patients with oligometastatic disease or primary NSCLC.
引用
收藏
页数:17
相关论文
共 67 条
  • [1] Ahmed M, 2014, RADIOLOGY, V273, P241, DOI [10.1148/radiol.14132958, 10.1016/j.jvir.2014.08.027]
  • [2] Principles of and Advances in Percutaneous Ablation
    Ahmed, Muneeb
    Brace, Christopher L.
    Lee, Fred T., Jr.
    Goldberg, S. Nahum
    [J]. RADIOLOGY, 2011, 258 (02) : 351 - 369
  • [3] Auris_Health_Inc, 2020, MONARCH PLATF US MAN
  • [4] Radiofrequency Ablation of Lung Tumors in Swine Assisted by a Navigation Device with Preprocedural Volumetric Planning
    Banovac, Filip
    Cheng, Patrick
    Campos-Nanez, Enrique
    Kallakury, Bhaskar
    Popa, Teo
    Wilson, Emmanuel
    Abeledo, Hernan
    Cleary, Kevin
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (01) : 122 - 129
  • [5] The three R's of lung health and disease: repair, remodeling, and regeneration
    Beers, Michael F.
    Morrisey, Edward E.
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 2011, 121 (06) : 2065 - 2073
  • [6] A comparative histological evaluation of the ablations produced by microwave, cryotherapy and radiofrequency in the liver
    Bhardwaj, N.
    Strickland, A. D.
    Ahmad, F.
    Atanesyan, L.
    West, K.
    Lloyd, D. M.
    [J]. PATHOLOGY, 2009, 41 (02) : 168 - 172
  • [7] Pulmonary Thermal Ablation: Comparison of Radiofrequency and Microwave Devices by Using Gross Pathologic and CT Findings in a Swine Model
    Brace, Christopher L.
    Hinshaw, J. Louis
    Laeseke, Paul F.
    Sampson, Lisa A.
    Lee, Fred T., Jr.
    [J]. RADIOLOGY, 2009, 251 (03) : 705 - 711
  • [8] Transbronchial microwave ablation of lung nodules with electromagnetic navigation bronchoscopy guidance-a novel technique and initial experience with 30 cases
    Chan, Joyce W. Y.
    Lau, Rainbow W. H.
    Ngai, Jenny C. L.
    Tsoi, Carita
    Chu, Cheuk Man
    Mok, Tony S. K.
    Ng, Calvin S. H.
    [J]. TRANSLATIONAL LUNG CANCER RESEARCH, 2021, 10 (04) : 1608 - +
  • [9] Characteristic CT Findings After Percutaneous Cryoablation Treatment of Malignant Lung Nodules
    Chaudhry, Ammar
    Grechushkin, Vadim
    Hoshmand, Mahsa
    Kim, Choo Won
    Pena, Andres
    Huston, Brett
    Chaya, Yair
    Bilfinger, Thomas
    Moore, William
    [J]. MEDICINE, 2015, 94 (42) : e1672
  • [10] Robotic Bronchoscopy for Peripheral Pulmonary Lesions A Multicenter Pilot and Feasibility Study (BENEFIT)
    Chen, Alexander C.
    Pastis, Nicholas J., Jr.
    Mahajan, Amit K.
    Khandhar, Sandeep J.
    Simoff, Michael J.
    Machuzak, Michael S.
    Cicenia, Joseph
    Gildea, Thomas R.
    Silvestri, Gerard A.
    [J]. CHEST, 2021, 159 (02) : 845 - 852