Excreted 99mTc-Pertechnetate in a Renal Pelvis as a Potential False Positive in a Meckel's Scan

被引:1
|
作者
Lanzo, Shannon M. [1 ,3 ]
Pantel, Austin R. [1 ]
Zhuang, Hongming [2 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA USA
[2] Univ Penn, Childrens Hosp Philadelphia, Perelman Sch Med, Philadelphia, PA USA
[3] Hosp Univ Penn, Dept Radiol, 3400 Spruce St, Philadelphia, PA 19104 USA
关键词
Tc-99m-pertechnetate; false-positive; gastrointestinal bleeding; Meckel's diverticulum; SPECT/CT; DIVERTICULUM;
D O I
10.1097/RLU.0000000000004331
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A 14-year-old girl presented with right lower quadrant pain. A Tc-99m-pertechnetate scan with SPECT/CT was performed to exclude a Meckel's diverticulum. The images demonstrated focal tracer uptake in the right midabdomen, which appeared early and decreased over time. However, SPECT/CT revealed that this uptake corresponded to the right renal pelvis, which was located more inferior than expected. This case emphasizes the importance of recognizing anatomic variants that may cause focal tracer uptake, as well as leveraging an understanding of tracer kinetics to inform a diagnosis.
引用
收藏
页码:173 / 175
页数:3
相关论文
共 11 条
  • [1] Rectal Juvenile Polyp Detected on 99mTc-Pertechnetate Abdominal Scintigraphy (Meckel Scan)
    Lee, Cheng Hiang
    O'Loughlin, Edward
    Chung, David Ken Vin
    CLINICAL NUCLEAR MEDICINE, 2013, 38 (06) : 474 - 477
  • [2] False positive in the detection of ectopic gastric mucosa in the 99mTc-pertechnetate abdominal scintigraphy
    Santiago Chinchilla, A.
    Ramos-Font, C.
    Palacios Gerona, H.
    Moreno Caballero, M.
    Rebollo Aguirre, A. C.
    Llamas Elvira, J. M.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR, 2010, 29 (06): : 310 - 311
  • [3] Potential False-Positive Meckel's Scan Caused by Umbilical Ornamentation
    Pillenahalli Maheshwarappa, Ravishankar
    Menda, Yusuf
    CLINICAL NUCLEAR MEDICINE, 2020, 45 (09) : 735 - 737
  • [4] Ectopic Kidney Mimicking a Meckel's Diverticulum on Tc-99m Pertechnetate Scan
    Blackmon, Kevin N.
    Rao, Anil G.
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (12) : E228 - E230
  • [5] Potential False-Positive Meckel Scan Due to Displaced Kidney Caused by Recurrent Retroperitoneal Teratoma
    Su, Tzu-Pei
    Cheng, Nai-Ming
    Chuang, Hui-Chieh
    Chen, Chien-Cheng
    Lin, Chieh
    CLINICAL NUCLEAR MEDICINE, 2014, 39 (10) : E433 - E435
  • [6] Laparoscopy as a cause of a false-positive Meckel's scan
    McKevitt, EC
    Baerg, JE
    Nadel, HR
    Webber, EM
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (02) : 102 - 104
  • [7] Omental Hernia as a Potential Cause of False-Positive GI Bleeding on 99mTc-RBC Scintigraphy
    Karamian, Farivash
    Sahafi, Pegah
    Tanha, Amin Saber
    Sadeghi, Ramin
    CLINICAL NUCLEAR MEDICINE, 2024, 49 (09) : e468 - e469
  • [8] Usefulness of 99mTc-pertechnetate whole body scan with neck and chest SPECT/CT for detection of post-surgical thyroid remnant and metastasis in differentiated thyroid cancer patients
    Maythinee Chantadisai
    Kanaungnit Kingpetch
    Annals of Nuclear Medicine, 2014, 28 : 674 - 682
  • [9] Usefulness of 99mTc-pertechnetate whole body scan with neck and chest SPECT/CT for detection of post-surgical thyroid remnant and metastasis in differentiated thyroid cancer patients
    Chantadisai, Maythinee
    Kingpetch, Kanaungnit
    ANNALS OF NUCLEAR MEDICINE, 2014, 28 (07) : 674 - 682
  • [10] Hyperphosphatemia-Related False-Positive 99mTc-Pyrophosphate Myocardial Scan: A Case Report With Endomyocardial Biopsy Result
    Hu, Lien-Hsin
    Kuo, Yu
    Chang, Fu-Pang
    Wang, Wei-Ting
    Yang, Bang-Hung
    Huang, Wen-Sheng
    Wang, Yuh-Feng
    CLINICAL NUCLEAR MEDICINE, 2023, 48 (11) : E544 - E546