Thermal performance and indoor air quality in new, medium density houses - Auckland, New Zealand

被引:3
作者
Birchmore, Roger Clive [1 ]
Berry, Terri-Ann [1 ]
Wallis, Shannon L. [1 ]
Tsai, Steve [1 ]
Hernandez, German [1 ]
机构
[1] Unitec Inst Technol, Dept Engn & Construct, Auckland, New Zealand
关键词
Performance analysis; Airtightness; Indoor air quality; Medium density housing; Particulate matter; TVOC; POLLUTION; TIME;
D O I
10.1108/IJBPA-08-2021-0110
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Purpose New Zealand's historical housing stock comprises largely single-storey detached houses, characterised by poor winter comfort with high air infiltration. Challenges with affordability and land use are shifting New Zealand's housing stock towards double-storey, conjoined medium-density housing (MDH). Reduced external surfaces in this typology should reduce winter heat loss and infiltration, improving winter comfort and health. New concerns arise, however, regarding summertime overheating and poor indoor air quality. Design/methodology/approach A field study was undertaken where temperature, humidity, airtightness, particulate matter (PM) and total volatile organic compounds (TVOC) were measured in two unoccupied, newly built double-storey, conjoined houses, for several weeks over summer. Findings The reduced surface area of this typology did not reduce infiltration and demonstrated significant periods of overheating. Internal PM concentrations generally exceeded outdoor concentrations but did not exceed annual average outdoor PM10 guidelines of 20 mu g m-3. Infiltration factors (Finf) were closer to more traditional houses. TVOC readings varied widely, but frequently exceeded international guidelines. Research limitations/implications The small sample limits the applications of conclusions more widely. Recommendations to investigate a wider sample in different locations with more detailed VOC analysis over all seasons are made. Practical implications Improvements to internal environments cannot be guaranteed by housing typology changes alone and must still involve thoughtful environmental design. Social implications Housing typology changes may not improve internal living environments. Originality/value A move to the new MDH typology may not achieve expectations of airtightness and thermal improvement. New challenges arise from significant overheating and high TVOC levels, which may lead to new negative health effects.
引用
收藏
页码:279 / 300
页数:22
相关论文
共 50 条
  • [31] Assessment of the Effects of Using Wood Stoves on Indoor Air Quality in Two Types of Norwegian Houses
    Hamon, Mathieu
    Cao, Guangyu
    Skreiberg, Oyvind
    Georges, Laurent
    Seljeskog, Morten
    Khalil, Roger
    Sevault, Alexis
    Mathisen, Hans Martin
    COLD CLIMATE HVAC 2018: SUSTAINABLE BUILDINGS IN COLD CLIMATES, 2019, : 887 - 897
  • [32] Sources of indoor air pollution at a New Zealand urban primary school; a case study
    Bennett, Julie
    Davy, Perry
    Trompetter, Bill
    Wang, Yu
    Pierse, Nevil
    Boulic, Mikael
    Phipps, Robyn
    Howden-Chapman, Philippa
    ATMOSPHERIC POLLUTION RESEARCH, 2019, 10 (02) : 435 - 444
  • [33] Building tight - ventilating right? How are new air tightness standards affecting indoor air quality in dwellings?
    Howieson, S. G.
    Sharpe, T.
    Farren, P.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2014, 35 (05) : 475 - 487
  • [34] Source apportionment of air pollutants in the Greater Auckland Region of New Zealand using receptor models and elemental levels in the lichen, Parmotrema reticulatum
    Boamponsem, Louis K.
    de Freitas, C. R.
    Williams, David
    ATMOSPHERIC POLLUTION RESEARCH, 2017, 8 (01) : 101 - 113
  • [35] Assessing indoor air quality in New York City nail salons
    Pavilonis, Brian
    Roelofs, Cora
    Blair, Carly
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2018, 15 (05) : 422 - 429
  • [36] An investigation of indoor air quality in rural residential houses in India - A case study
    Lawrence, A
    Taneja, A
    INDOOR AND BUILT ENVIRONMENT, 2005, 14 (3-4) : 321 - 329
  • [37] Investigation on Indoor Air Quality at Rural Houses in Winter in Severe Cold Region
    Wang, Zhaojun
    Xie, Dongdong
    Tang, Rui
    Sheng, Xiaohui
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 1: INDOOR AND OUTDOOR ENVIRONMENT, 2014, 261 : 69 - 75
  • [38] Field investigation of indoor air quality and ventilation characteristics in selected Irish houses
    Guo, LY
    Lewis, J
    Kelly, A
    Lennon, D
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 691 - 697
  • [39] Different Fuel Types and Heating Approaches Impact on the Indoor Air Quality of Rural Houses in Northern China
    Zhang, Xueyan
    Chen, Bin
    Fan, Xinying
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 493 - 500
  • [40] INDOOR AIR QUALITY IN THE SCHOOLS AND STUDENTS PERFORMANCE
    Senitkova, Ingrid
    Bednarova, Petra
    NANO, BIO AND GREEN - TECHNOLOGIES FOR A SUSTAINABLE FUTURE, VOL II (SGEM 2015), 2015, : 445 - 454