Thermal performance and indoor air quality in new, medium density houses - Auckland, New Zealand

被引:3
作者
Birchmore, Roger Clive [1 ]
Berry, Terri-Ann [1 ]
Wallis, Shannon L. [1 ]
Tsai, Steve [1 ]
Hernandez, German [1 ]
机构
[1] Unitec Inst Technol, Dept Engn & Construct, Auckland, New Zealand
关键词
Performance analysis; Airtightness; Indoor air quality; Medium density housing; Particulate matter; TVOC; POLLUTION; TIME;
D O I
10.1108/IJBPA-08-2021-0110
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Purpose New Zealand's historical housing stock comprises largely single-storey detached houses, characterised by poor winter comfort with high air infiltration. Challenges with affordability and land use are shifting New Zealand's housing stock towards double-storey, conjoined medium-density housing (MDH). Reduced external surfaces in this typology should reduce winter heat loss and infiltration, improving winter comfort and health. New concerns arise, however, regarding summertime overheating and poor indoor air quality. Design/methodology/approach A field study was undertaken where temperature, humidity, airtightness, particulate matter (PM) and total volatile organic compounds (TVOC) were measured in two unoccupied, newly built double-storey, conjoined houses, for several weeks over summer. Findings The reduced surface area of this typology did not reduce infiltration and demonstrated significant periods of overheating. Internal PM concentrations generally exceeded outdoor concentrations but did not exceed annual average outdoor PM10 guidelines of 20 mu g m-3. Infiltration factors (Finf) were closer to more traditional houses. TVOC readings varied widely, but frequently exceeded international guidelines. Research limitations/implications The small sample limits the applications of conclusions more widely. Recommendations to investigate a wider sample in different locations with more detailed VOC analysis over all seasons are made. Practical implications Improvements to internal environments cannot be guaranteed by housing typology changes alone and must still involve thoughtful environmental design. Social implications Housing typology changes may not improve internal living environments. Originality/value A move to the new MDH typology may not achieve expectations of airtightness and thermal improvement. New challenges arise from significant overheating and high TVOC levels, which may lead to new negative health effects.
引用
收藏
页码:279 / 300
页数:22
相关论文
共 50 条
  • [21] Research of the Indoor Air quality of New Decoration Residence in Tianjin
    Li, Guojian
    Jiang, Ping
    Zhu, Neng
    2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 3, PROCEEDINGS, 2009, : 94 - +
  • [22] Indoor air quality of new hotels: Grey theory approach
    Chan, Wilco
    Lee, Shuncheng
    Chan, Jazz
    Chen, Youming
    Mak, Barry
    Zheng, Cong
    Guo, Xingguo
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 745 - 750
  • [23] The influence of the concealed pollution sources upon the indoor air quality in houses
    Hayashi, M
    Osawa, H
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1957 - 1962
  • [24] Indoor air quality and academic performance
    Stafford, Tess M.
    JOURNAL OF ENVIRONMENTAL ECONOMICS AND MANAGEMENT, 2015, 70 : 34 - 50
  • [25] Living Conditions in Timber Houses: Emission Trends and Indoor Air Quality
    Fuerhapper, Christina
    Habla, Elisabeth
    Stratev, Daniel
    Weigl, Martin
    Dobianer, Karl
    FRONTIERS IN BUILT ENVIRONMENT, 2020, 5
  • [26] Indoor Air Quality of Houses Located in the Urban Environment of Agra, India
    Taneja, Ajay
    Saini, Renuka
    Masih, Amit
    ENVIRONMENTAL CHALLENGES IN THE PACIFIC BASIN, 2008, 1140 : 228 - 245
  • [27] The influence of the concealed pollution sources upon the indoor air quality in houses
    Hayashi, M.
    Osawa, H.
    BUILDING AND ENVIRONMENT, 2008, 43 (03) : 329 - 336
  • [28] Measurement and evaluation of indoor air quality by passive method in Korean houses
    Kim, H
    Tabuchi, S
    Tanabe, S
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 712 - 717
  • [29] Assessment of Indoor Air Quality in Residential Buildings of New England through Actual Data
    Gonzalo, Fernando del Ama
    Griffin, Matthew
    Laskosky, Jacob
    Yost, Peter
    Gonzalez-Lezcano, Roberto Alonso
    SUSTAINABILITY, 2022, 14 (02)
  • [30] Assessment of the Effects of Using Wood Stoves on Indoor Air Quality in Two Types of Norwegian Houses
    Hamon, Mathieu
    Cao, Guangyu
    Skreiberg, Oyvind
    Georges, Laurent
    Seljeskog, Morten
    Khalil, Roger
    Sevault, Alexis
    Mathisen, Hans Martin
    COLD CLIMATE HVAC 2018: SUSTAINABLE BUILDINGS IN COLD CLIMATES, 2019, : 887 - 897