Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements?

被引:0
|
作者
Jungwirth-Weinberger, Anna [1 ,2 ]
Hanreich, Carola [1 ]
Kasparek, Maximilian F. [3 ]
Renner, Lisa [4 ]
Waldstein, Wenzel [5 ]
Boettner, Friedrich [1 ]
机构
[1] Hosp Special Surg, 535 East 70th St, New York, NY 10021 USA
[2] Kantonsspital Baden, Ergel 1, CH-5404 Baden, Switzerland
[3] Evangel Krankenhaus, Hans Sachs Gasse 10-12, A-1180 Vienna, Austria
[4] Charite, Charitepl 1, D-10117 Berlin, Germany
[5] AKH Wien, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
关键词
Metal-on-metal; Total hip arthroplasty; Revision; Chromium; Cobalt; ARTHROPLASTY; DISLOCATION; BEARING;
D O I
10.1007/s00402-021-04206-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Increased cobalt (Co) and chromium (Cr) serum levels are one reason for revision surgery in metal on metal (MoM) total hip arthroplasty (THA) patients. Dual mobility liners are a simple revision option; however, they preserve the metal shell and stem and it is therefore not clear if metal ion levels will fully normalize after revision surgery. Material and methods Between April 2013 and December 2017 25 hips (24 patients) underwent revision from a MoM THA to an off-label dual mobility liner. Five patients were lost to follow-up and one patient refused leaving 18 patients (11 men, 7 female, average age 63.9 years) for pre- and postoperative metal ion level blood tests at a minimum follow-up of 2 years. Results Fourteen patients were revised for osteolysis, two for elevated metal ion levels and two for fluid or cysts around the femoral or acetabular component. The average preoperative Co and Cr levels were 8.3 mu g/l and 5.0 mu g/l, respectively. At a minimum follow-up of 2 years (30-95 months), metal ions dropped to 0.8 mu g/l. Harris Hip Score (HHS), Hip Osteoarthritis Outcome Score (HOOS), Visual Analog Scale (VAS) and the UCLA activity score improved non-significantly from pre- to postoperative. There was one postoperative complication in the study cohort. One patient with persisting pain required revision surgery to a standard acetabular component during the follow-up period. Conclusion The off-label use of a dual-mobility liner in the current study resulted in normalization of the metal ion levels suggesting that preserving the cobalt-chromium acetabular component has little impact on ion levels. In addition, dual mobility liners have a low complication and revision rate.
引用
收藏
页码:1217 / 1221
页数:5
相关论文
共 50 条
  • [41] Modes of Failure in Metal-on-Metal Total Hip Arthroplasty
    Fehring, Keith A.
    Fehring, Thomas K.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (02) : 185 - +
  • [42] Chromium speciation in the blood of metal-on-metal hip implant patients
    Finley, Brent
    Scott, Paul K.
    Glynn, Meghan E.
    Paustenbach, Dennis
    Donovan, Ellen
    Thuett, Kerry A.
    TOXICOLOGICAL AND ENVIRONMENTAL CHEMISTRY, 2017, 99 (01) : 48 - 64
  • [43] Metal-on-Metal Total Hip Revisions: Pearls and Pitfalls
    Law, Jesua, I
    Crawford, David A.
    Adams, Joanne B.
    Lombardi, Adolph V., Jr.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (06) : S68 - S72
  • [44] 2008 John Charnley Award: Metal Ion Levels After Metal-on-Metal Total Hip Arthroplasty: A Randomized Trial
    Engh, C. Anderson, Jr.
    MacDonald, Steven J.
    Sritulanondha, Supatra
    Thompson, Abigail
    Naudie, Douglas
    Engh, Charles A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) : 101 - 111
  • [45] Metal Ion Levels After Metal-on-Metal Total Hip Arthroplasty A Five-Year, Prospective Randomized Trial
    Engh, C. A.
    MacDonald, S. J.
    Sritulanondha, S.
    Korczak, A.
    Naudie, D.
    Engh, C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (06) : 448 - 455
  • [46] Predicting Wear and Blood Metal Ion Levels in Metal-on-Metal Hip Resurfacing
    Matthies, Ashley K.
    Henckel, Johann
    Cro, Suzie
    Suarez, Alexander
    Noble, Philip C.
    Skinner, John
    Hart, Alister J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (01) : 167 - 174
  • [47] The clinical significance of metal ion release from cobalt-chromium metal-on-metal hip joint arthroplasty
    Cobb, AG
    Schmalzreid, TP
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) : 385 - 398
  • [48] Predictivity and Fate of Metal Ion Release From Metal-On-Metal Total Hip Prostheses
    Nicolli, Annamaria
    Bisinella, Gianluca
    Padovani, Giovanni
    Vitella, Antonio
    Chiara, Federica
    Trevisan, Andrea
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09) : 1763 - 1767
  • [49] Revision of metal-on-metal hip replacements and resurfacings for adverse reaction to metal debris: a systematic review of outcomes
    Matharu, Gulraj S.
    Pynsent, Paul B.
    Dunlop, David J.
    HIP INTERNATIONAL, 2014, 24 (04) : 311 - 320
  • [50] Metal-on-metal bearings total hip arthroplasty: The cobalt and chromium ions release concern
    Delaunay, C.
    Petit, I.
    Learmonth, I. D.
    Oger, P.
    Vendittoli, P. A.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (08) : 894 - 904