Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements?

被引:0
|
作者
Jungwirth-Weinberger, Anna [1 ,2 ]
Hanreich, Carola [1 ]
Kasparek, Maximilian F. [3 ]
Renner, Lisa [4 ]
Waldstein, Wenzel [5 ]
Boettner, Friedrich [1 ]
机构
[1] Hosp Special Surg, 535 East 70th St, New York, NY 10021 USA
[2] Kantonsspital Baden, Ergel 1, CH-5404 Baden, Switzerland
[3] Evangel Krankenhaus, Hans Sachs Gasse 10-12, A-1180 Vienna, Austria
[4] Charite, Charitepl 1, D-10117 Berlin, Germany
[5] AKH Wien, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
关键词
Metal-on-metal; Total hip arthroplasty; Revision; Chromium; Cobalt; ARTHROPLASTY; DISLOCATION; BEARING;
D O I
10.1007/s00402-021-04206-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Increased cobalt (Co) and chromium (Cr) serum levels are one reason for revision surgery in metal on metal (MoM) total hip arthroplasty (THA) patients. Dual mobility liners are a simple revision option; however, they preserve the metal shell and stem and it is therefore not clear if metal ion levels will fully normalize after revision surgery. Material and methods Between April 2013 and December 2017 25 hips (24 patients) underwent revision from a MoM THA to an off-label dual mobility liner. Five patients were lost to follow-up and one patient refused leaving 18 patients (11 men, 7 female, average age 63.9 years) for pre- and postoperative metal ion level blood tests at a minimum follow-up of 2 years. Results Fourteen patients were revised for osteolysis, two for elevated metal ion levels and two for fluid or cysts around the femoral or acetabular component. The average preoperative Co and Cr levels were 8.3 mu g/l and 5.0 mu g/l, respectively. At a minimum follow-up of 2 years (30-95 months), metal ions dropped to 0.8 mu g/l. Harris Hip Score (HHS), Hip Osteoarthritis Outcome Score (HOOS), Visual Analog Scale (VAS) and the UCLA activity score improved non-significantly from pre- to postoperative. There was one postoperative complication in the study cohort. One patient with persisting pain required revision surgery to a standard acetabular component during the follow-up period. Conclusion The off-label use of a dual-mobility liner in the current study resulted in normalization of the metal ion levels suggesting that preserving the cobalt-chromium acetabular component has little impact on ion levels. In addition, dual mobility liners have a low complication and revision rate.
引用
收藏
页码:1217 / 1221
页数:5
相关论文
共 50 条
  • [31] Survivorship of a Metal-on-Metal Total Hip Implant With Modular Titanium Adapter
    Semaan, Derek J.
    Rutledge-Jukes, Heath
    Berend, Keith R.
    Lombardi, Adolph V., Jr.
    Adams, Joanne B.
    Crawford, David A.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (07) : S560 - S565
  • [32] Changes in Cobalt and Chromium Levels After Metal-on-Metal Hip Resurfacing in Young, Active Chinese Patients
    Yang, Jing
    Shen, Bin
    Zhou, ZongKe
    Pei, Fuxing
    Kang, PengDe
    JOURNAL OF ARTHROPLASTY, 2011, 26 (01) : 65 - 70
  • [33] Do Ion Levels In Hip Resurfacing Differ From Metal-on-metal THA at Midterm?
    Moroni, A.
    Savarino, L.
    Hoque, M.
    Cadossi, M.
    Baldini, N.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (01) : 180 - 187
  • [34] Do Ion Levels in Metal-on-metal Hip Resurfacing Differ From Those in Metal-on-metal THA at Long-term Followup?
    Savarino, Lucia
    Cadossi, Matteo
    Chiarello, Eugenio
    Baldini, Nicola
    Giannini, Sandro
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (09) : 2964 - 2971
  • [35] Evaluation of the Method for Analyzing Chromium, Cobalt and Titanium Ion Levels in the Blood Following Hip Replacement with a Metal-on-Metal Prosthesis
    Barry, Janie
    Lavigne, Martin
    Vendittoli, Pascal-Andre
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2013, 37 (02) : 90 - 96
  • [36] Management of failed metal-on-metal total hip arthroplasty
    Griffin, Justin W.
    D'Apuzzo, Michele
    Browne, James A.
    WORLD JOURNAL OF ORTHOPEDICS, 2012, 3 (06): : 70 - 74
  • [37] Adverse Local Tissue Reaction After a Metal-on-Metal Total Hip Prosthesis Without Elevated Serum Metal Ion Levels
    Tetreault, Matthew W.
    Jacobs, Joshua J.
    Mahmud, Waqas
    Nam, Denis
    ORTHOPEDICS, 2018, 41 (03) : E438 - E441
  • [38] Changes in blood ion levels after removal of metal-on-metal hip replacements 16 patients followed for 0-12 months
    Durrani, Salim K.
    Noble, Philip C.
    Sampson, Barry
    Panetta, Therese
    Liddle, Alexander D.
    Sabah, Shiraz A.
    Chan, Newton K.
    Skinner, John A.
    Hart, Alister J.
    ACTA ORTHOPAEDICA, 2014, 85 (03) : 259 - 265
  • [39] Metal ion levels after metal-on-metal hip resurfacing: A single-center longitudinal study of Chinese patients
    Wan, Yanlin
    You, Jia
    Jiang, Wenxue
    Wang, Pengfei
    Xia, Qun
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (04) : 196 - 202
  • [40] Metal Ion Levels Not Sufficient as a Screening Measure for Adverse Reactions in Metal-on-Metal Hip Arthroplasties
    Macnair, Rory D.
    Wynn-Jones, Henry
    Wimhurst, James A.
    Toms, Andoni
    Cahir, John
    JOURNAL OF ARTHROPLASTY, 2013, 28 (01) : 78 - 83