Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements?

被引:0
|
作者
Jungwirth-Weinberger, Anna [1 ,2 ]
Hanreich, Carola [1 ]
Kasparek, Maximilian F. [3 ]
Renner, Lisa [4 ]
Waldstein, Wenzel [5 ]
Boettner, Friedrich [1 ]
机构
[1] Hosp Special Surg, 535 East 70th St, New York, NY 10021 USA
[2] Kantonsspital Baden, Ergel 1, CH-5404 Baden, Switzerland
[3] Evangel Krankenhaus, Hans Sachs Gasse 10-12, A-1180 Vienna, Austria
[4] Charite, Charitepl 1, D-10117 Berlin, Germany
[5] AKH Wien, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
关键词
Metal-on-metal; Total hip arthroplasty; Revision; Chromium; Cobalt; ARTHROPLASTY; DISLOCATION; BEARING;
D O I
10.1007/s00402-021-04206-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Increased cobalt (Co) and chromium (Cr) serum levels are one reason for revision surgery in metal on metal (MoM) total hip arthroplasty (THA) patients. Dual mobility liners are a simple revision option; however, they preserve the metal shell and stem and it is therefore not clear if metal ion levels will fully normalize after revision surgery. Material and methods Between April 2013 and December 2017 25 hips (24 patients) underwent revision from a MoM THA to an off-label dual mobility liner. Five patients were lost to follow-up and one patient refused leaving 18 patients (11 men, 7 female, average age 63.9 years) for pre- and postoperative metal ion level blood tests at a minimum follow-up of 2 years. Results Fourteen patients were revised for osteolysis, two for elevated metal ion levels and two for fluid or cysts around the femoral or acetabular component. The average preoperative Co and Cr levels were 8.3 mu g/l and 5.0 mu g/l, respectively. At a minimum follow-up of 2 years (30-95 months), metal ions dropped to 0.8 mu g/l. Harris Hip Score (HHS), Hip Osteoarthritis Outcome Score (HOOS), Visual Analog Scale (VAS) and the UCLA activity score improved non-significantly from pre- to postoperative. There was one postoperative complication in the study cohort. One patient with persisting pain required revision surgery to a standard acetabular component during the follow-up period. Conclusion The off-label use of a dual-mobility liner in the current study resulted in normalization of the metal ion levels suggesting that preserving the cobalt-chromium acetabular component has little impact on ion levels. In addition, dual mobility liners have a low complication and revision rate.
引用
收藏
页码:1217 / 1221
页数:5
相关论文
共 50 条
  • [1] Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements?
    Anna Jungwirth-Weinberger
    Carola Hanreich
    Maximilian F. Kasparek
    Lisa Renner
    Wenzel Waldstein
    Friedrich Boettner
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 1217 - 1221
  • [2] Serum Metal Ion Concentrations Decline (But Do Not Rapidly Normalize) Following Revision of Metal-on-Metal Total Hip Bearings
    Browne, James A.
    Wan, Zhinian
    Novicoff, Wendy M.
    Cui, Quanjun
    Brown, Thomas E.
    METAL-ON-METAL TOTAL HIP REPLACEMENT DEVICES, 2013, 1560 : 51 - 60
  • [3] Revision rates for metal-on-metal hip resurfacing and metal-on-metal total hip arthroplasty - a systematic review
    Sorensen, Sofie-Amalie L. Ras
    Jorgensen, Henrik L.
    Sporing, Sune L.
    Lauritzen, Jes B.
    HIP INTERNATIONAL, 2016, 26 (06) : 515 - 521
  • [4] Do cobalt and chromium levels predict osteolysis in metal-on-metal total hip arthroplasty?
    Renner, Lisa
    Schmidt-Braekling, Tom
    Faschingbauer, Martin
    Boettner, Friedrich
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (12) : 1657 - 1662
  • [5] Higher Blood Cobalt and Chromium Levels in Patients With Unilateral Metal-on-Metal Total Hip Arthroplasties Compared to Hip Resurfacings
    Lainiala, Olli S.
    Moilanen, Teemu P. S.
    Hart, Alister J.
    Huhtala, Heini S. A.
    Sabah, Shiraz A.
    Eskelinen, Antti P.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (06) : 1261 - 1266
  • [6] Do cobalt and chromium levels predict osteolysis in metal-on-metal total hip arthroplasty?
    Lisa Renner
    Tom Schmidt-Braekling
    Martin Faschingbauer
    Friedrich Boettner
    Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 1657 - 1662
  • [7] Total hip replacements with metal-on-metal bearings
    Milosev, Ingrid
    Kovac, Simon
    Topolovec, Matevz
    Pisot, Venceslav
    Trebse, Rihard
    ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2009, 78 : 34 - 40
  • [8] Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements
    Lhotka, C
    Szekeres, T
    Steffan, I
    Zhuber, K
    Zweymüller, K
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (02) : 189 - 195
  • [9] Serum metal ion levels after second-generation metal-on-metal total hip arthroplasty
    Takao Imanishi
    Masahiro Hasegawa
    Akihiro Sudo
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 1447 - 1450
  • [10] Low Cobalt and Chromium Levels from a Single Metal-on-Metal Total Hip Arthroplasty Implant
    Chen, Antonia F.
    Pigott, Matthew T.
    McClain, Edward J.
    Klatt, Brian A.
    METAL-ON-METAL TOTAL HIP REPLACEMENT DEVICES, 2013, 1560 : 61 - 72