摘要
Phase measuring deflectometry is a powerful measurement tool of optical surfaces, but the measuring accuracy relies on the quality of system calibration. Calibration errors arise from the oversimplified imaging models, error accumulation and amplification, and the bias in numerical optimization. A holistic calibration method is proposed to shorten the error propagation chain. The descriptive prowess of the imaging system is enhanced by calculating each incident ray independently and compensating the systematic errors resulting from the form error of the calibration mirror. Finally, a holonomic framework prior is defined to guarantee the calibration reliability by utilizing the physical constraints of the measurement system. Experimental results demonstrate that the proposed method improves measurement accuracy by at least 38% compared to traditional approaches. (c) 2024 Optica Publishing Group
引用
收藏
页码:702 / 705
页数:4
相关论文
共 49 条
  • [21] Radiometric calibration method for large aperture infrared system with broad dynamic range
    Sun, Zhiyuan
    Chang, Songtao
    Zhu, Wei
    APPLIED OPTICS, 2015, 54 (15) : 4659 - 4666
  • [22] Hand-eye calibration method fusing rotational and translational constraint information
    Zhang, Zhaorui
    Zhang, Xu
    Zheng, Zelong
    Tu, Dawei
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2015, 36 (11): : 2443 - 2450
  • [23] Research on static calibration method of flexible three-dimensional tactile sensor
    Huang, Bin
    Yu, Xiaofen
    Huang, Ying
    Huang, Haiyang
    Wang, Biao
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (09): : 2003 - 2009
  • [24] Calibration method for a multi-focus microscopic 3D imaging system
    Chen, Liming
    Xiang, Wang
    Zhang, Song
    OPTICS LETTERS, 2023, 48 (16) : 4348 - 4351
  • [25] PROGRESS IN THE DEVELOPMENT OF STANDARD PROCEDURES FOR THE GLOBAL METHOD OF CALIBRATION OF PHOTOVOLTAIC REFERENCE CELLS.
    Whitaker, Richard D.
    Purnell, Arthur W.
    Zerlaut, Gene A.
    Solar Cells: Their Science, Technology, Applications and Economics, 1981, 7 (1-2): : 135 - 146
  • [26] A framework for assessing low-carbon city based on AHP method
    Li, B. (xacjlibingjie@163.com), 2013, Research India Publications (08):
  • [27] Automatic Calibration - A New Method for Eliminating Systematic Errors in Measuring Systems with Linear Characteristic.
    Wagner, Friedrich Ernst
    Mirahmadi, Amin
    Technisches Messen TM, 1979, 46 (01): : 15 - 19
  • [28] Reducing Uncertainty and Risk of a Dam by Site Investigation, Quantitative Analysis, Model Calibration, and Observational Method
    Ding, Dan
    Boeckmann, Andrew
    Axtell, Paul J.
    Loehr, J. Erik
    Geotechnical Special Publication, 2023, 2023-July (GSP 345): : 295 - 310
  • [29] Proposal of calibration method for 3-D digestive endoscope using grid active stereo
    Aoki, Hirooki
    Furukawa, Ryo
    Nishitani, Ishin
    Aoyama, Masahito
    Hiura, Shinsaku
    Kominami, Yoko
    Matsuo, Taiji
    Yoshida, Shigeto
    Tanaka, Shinji
    Sagawa, Ryusuke
    Kawasaki, Hiroshi
    Transactions of Japanese Society for Medical and Biological Engineering, 2014, 52 (02): : 97 - 107
  • [30] New Method of Calibration in Atomic Absorption Spectrometry Using a Single Standard for Analyses of Steel.
    Gregorczyk, Stanislaw
    Wycislik, Andrzej
    Hutnik Warszawa, 1979, 46 (12): : 514 - 517