Holistic calibration method of deflectometry by holonomic framework priors

被引:1
|
作者
Lang, Wei [1 ]
Zhang, Xiangchao [1 ]
Chen, Yunuo [1 ]
Chen, Ting [1 ]
Jiang, Xiangqian [1 ,2 ]
机构
[1] Fudan Univ, Shanghai Engn Res Ctr Ultraprecis Opt Mfg, Sch Informat Sci & Technol, Shanghai 200438, Peoples R China
[2] Univ Huddersfield, Future Metrol Hub, Huddersfield HD1 3DH, England
基金
中国国家自然科学基金; 英国工程与自然科学研究理事会;
关键词
Compendex;
D O I
10.1364/OL.513949
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Phase measuring deflectometry is a powerful measurement tool of optical surfaces, but the measuring accuracy relies on the quality of system calibration. Calibration errors arise from the oversimplified imaging models, error accumulation and amplification, and the bias in numerical optimization. A holistic calibration method is proposed to shorten the error propagation chain. The descriptive prowess of the imaging system is enhanced by calculating each incident ray independently and compensating the systematic errors resulting from the form error of the calibration mirror. Finally, a holonomic framework prior is defined to guarantee the calibration reliability by utilizing the physical constraints of the measurement system. Experimental results demonstrate that the proposed method improves measurement accuracy by at least 38% compared to traditional approaches. (c) 2024 Optica Publishing Group
引用
收藏
页码:702 / 705
页数:4
相关论文
共 49 条
  • [1] CALIBRATION OF DC VERNIER POTENTIOMETER BY AC METHOD.
    Choudhury, J.K.
    Kejariwal, P.C.
    Ghosh, S.K.
    1600, (53):
  • [2] ORIENTATION AND CALIBRATION METHOD FOR NON-TOPOGRAPHIC APPLICATIONS
    BOPP, H
    KRAUSS, H
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 1978, 44 (09): : 1191 - 1196
  • [3] High-precision binocular camera calibration method based on a 3D calibration object
    Zhang, Xiaowen
    Lv, Tiegang
    Dan, Wang
    Zhang, Minghao
    APPLIED OPTICS, 2024, 63 (10) : 2667 - 2682
  • [4] NEW METHOD FOR THE CALIBRATION OF THE INERTIA OF RESONANT COLUMN DEVICES.
    Tatsuoka, Fumio
    Silver, M.L.
    Geotechnical Testing Journal, 1980, 3 (01): : 30 - 34
  • [5] An integrated calibration method for the cross-shaped magnetic gradiometer
    Ma, Jianfei
    Tan, Haifeng
    Wang, Zhiqiang
    Yang, Mingquan
    AIP ADVANCES, 2023, 13 (07)
  • [6] A calibration method on base excitation amplitude of piezoelectric ceramic exciter
    Li, Hui
    Liu, Ying
    Wang, Yu
    Sun, Wei
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2015, 36 (06): : 832 - 837
  • [7] Calibration method for the core parameters of high temperature strain gauges
    Wang, Wen-Rui
    Zhang, Jia-Ming
    Yan, Xiao-Qiang
    Sun, Zhi-Hui
    Gongcheng Kexue Xuebao/Chinese Journal of Engineering, 2015, 37 (12): : 1645 - 1650
  • [8] Camera distortion calibration method based on straight line characteristics
    Zhang, Min
    Jin, Longxu
    Li, Guoning
    Wu, Yinan
    Han, Shuangli
    Guangxue Xuebao/Acta Optica Sinica, 2015, 35 (06):
  • [9] Calibration method for multiple line structured light vision sensors
    Liu, Zhen
    Huang, Bangkui
    Wei, Xinguo
    Zhang, Guangjun
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2012, 48 (20): : 16 - 21
  • [10] A Multi-Level Framework for Traffic Safety Assessment under Automated Driving Functionalities: the Need and Outline of a Holistic Approach
    Charoniti, Eleni
    Klunder, Gerdien
    Meeuwissen, Marcel
    International Journal of Automotive Engineering, 2024, 15 (01): : 27 - 35