Diurnal Variation in Tear Film Lipid Layer Using Smartphone-based Interferometry

被引:1
|
作者
Okazaki, Yoshiro [1 ,3 ]
Iwabuchi, Mamoru [1 ]
Yokoi, Norihiko [2 ]
机构
[1] Waseda Univ, Fac Human Sci, Tokyo, Japan
[2] Kyoto Prefectural Univ Med, Dept Ophthalmol, Kyoto, Japan
[3] 2-579-15 Mikajima, Tokorozawa, Saitama 3591192, Japan
关键词
smartphone-based interferometer; tear film lipid layer; diurnal variation; dry eye; DEFICIENCY DRY EYE; KINETIC-ANALYSIS; DIAGNOSIS; CONTACT; THICKNESS; PATTERNS;
D O I
10.14326/abe.12.163
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tear film stability is essential for maintaining the health of the ocular surface. A tear film interferometer allows noninvasive observation of the dynamics of the tear film lipid layer, thereby enabling the evaluation of tear film stability. However, an interferometer is a medical device used only in clinical settings and is therefore not accessible to the general public. Self-checking of tear film stability in daily life may help prevent dry eye. This study investigates diurnal variation in the tear film lipid layer in daily life using a prototype smartphone-based interferometer. The system consists of a luminescent sheet attached to a smartphone camera, which allows the user to easily videorecord the dynamic behavior of the tear film lipid layer. Thirteen participants (5 with and 8 without contact lenses) were asked to record videos of their tear film five times per day. The diurnal variation of interference grade, spread grade, non-invasive break-up time, maximum blink interval, tear meniscus height, and dry-eye-related subjective symptoms evaluated using the visual analog scale were measured. The results revealed a significant decrease in mean tear meniscus height measured at 18:00 compared with 9:00 (P < 0.05) in participants without contact lenses. The mean interference grade at 15:00 and spread grade at 21:00 were significantly greater than those at 9:00 (P < 0.05) in participants with contact lenses. These results suggest that a smartphone-based interferometer is a potentially useful tool for evaluating tear film parameters in daily life.
引用
收藏
页码:163 / 170
页数:8
相关论文
共 50 条
  • [1] Smartphone-Based Interferometry for Non-Invasive Assessment of Tear Film Lipid Layer Kinetics
    Okazaki Y.
    Iwabuchi M.
    Yokoi N.
    IEEJ Transactions on Electronics, Information and Systems, 2024, 144 (05) : 406 - 410
  • [2] New Insights Into the Lipid Layer of the Tear Film and Meibomian Glands
    Arita, Reiko
    Fukuoka, Shima
    Morishige, Naoyuki
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (06): : 335 - 339
  • [3] Classification of Tear Film Lipid Layer En Face Maps Obtained Using Optical Coherence Tomography and Their Correlation With Clinical Parameters
    Stegmann, Hannes
    Dos Santos, Valentin Aranha
    Schmidl, Doreen
    Garhoefer, Gerhard
    Fard, Ali
    Bagherinia, Homayoun
    Schmetterer, Leopold
    Werkmeister, Rene M.
    CORNEA, 2023, 42 (04) : 490 - 497
  • [4] Repeatability of tear film lipid layer interferometry measurements: A randomized, crossover study
    Wang, Michael T. M.
    Misra, Stuti L.
    Gokul, Akilesh
    Kim, Ji Soo
    Kim, Andy D.
    Xue, Ally L.
    Cruzat, Andrea
    Craig, Jennifer P.
    OPTOMETRY AND VISION SCIENCE, 2025, 102 (03) : 167 - 174
  • [5] Functional Morphology of the Lipid Layer of the Tear Film
    Arita, Reiko
    Fukuoka, Shima
    Morishige, Naoyuki
    CORNEA, 2017, 36 : S60 - S66
  • [6] Mapping the Lipid Layer of the Human Tear Film
    Cohen, Yoel
    Trokel, Stephen
    Arieli, Yoel
    Epshtien, Shlomi
    Gefen, Raanan
    Harris, Alon
    CORNEA, 2020, 39 (01) : 132 - 135
  • [7] Determination of Tear Lipid Film Thickness Based on a Reflected Placido Disk Tear Film Analyzer
    Fu, Pin-, I
    Fang, Po-Chiung
    Ho, Ren-Wen
    Chao, Tsai-Ling
    Cho, Wan-Hua
    Lai, Hung-Yin
    Hsiao, Yu-Ting
    Kuo, Ming-Tse
    DIAGNOSTICS, 2020, 10 (06)
  • [8] High Resolution Microscopy of the Lipid Layer of the Tear Film
    King-Smith, P. Ewen
    Nichols, Jason J.
    Braun, Richard J.
    Nichols, Kelly K.
    OCULAR SURFACE, 2011, 9 (04): : 197 - 211
  • [9] Tear film lipid layer: A molecular level view
    Cwiklik, Lukasz
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2016, 1858 (10): : 2421 - 2430
  • [10] Image-based quantitative analysis of tear film lipid layer thickness for meibomian gland evaluation
    Hwang, Hyeonha
    Jeon, Hee-Jae
    Yow, Kin Choong
    Hwang, Ho Sik
    Chung, EuiHeon
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16