Bioanalytical method development and validation of a novel antiseizure agent Cenobamate using LC-MS/MS

被引:1
|
作者
Rao, Yamarthi Venkateswara [1 ,2 ]
Shaik, Rasheed Ahemad [3 ]
Chimakurthy, Jithendra [1 ]
机构
[1] Vignans Fdn Sci Technol & Res, Fac Pharm, Guntur 522513, Andhra Pradesh, India
[2] Vignans Fdn Sci Technol & Res, Dept Sci & Humanities, Div Chem, Guntur 522213, Andhra Pradesh, India
[3] King Abdulaziz Univ, Fac Pharm, Dept Pharmacol & Toxicol, Jeddah 21589, Saudi Arabia
关键词
Cenobamate; human plasma; epilepsy; robustness; validation; development; LC-MS/MS; TANDEM MASS-SPECTROMETRY; ANTIEPILEPTIC DRUGS; EPILEPSY;
D O I
10.1504/IJNT.2023.131103
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
To quantify Cenobamate in human plasma, a precise and sensitive electron ionisation procedure in tandem mass spectrometry has been developed. The study was successfully confirmed by using Cenobamate -D4 as the internal norm and tert-butyl methyl ether in the testing of several positive ionic reactions. It has been used in liquid-liquid extraction to prepare samples as an extraction solvent. Cenobamate and Cenobamate - D4 (internal standard) were separated on an Eclipse C18 column (150 mm, 4.6 mm, 5 mu m) by isocratic elution. This process was performed using a mobile phase of 0.1% formic acid in 20:80% v/v ratio of acetonitrile with a flow rate of 0.6 ml/min. The observed mass transitions for Cenobamate and D4 were m/z (amu) 268.23, 198.10 and 272.11 198.10 for each. The lower quantitative limit was 10 ng/ml based on 500 ng/ml plasma, with no chromatogram disturbance observed. A linear curve was observed with a correlation coefficient (r(2)) of 0.999 from 10 to 500 ng/ml. The intraday and interday precision variations were 15% and the accuracy values were 15% of the relative error values (RE). Extraction recovery rates are in the tolerance ranges of less than 15%. The new LC-MS/MS method complies with all regulatory requirements and demonstrates satisfactory accuracy and accuracy and is sensitive enough to detect Cenobamate in humans.
引用
收藏
页码:63 / 74
页数:13
相关论文
共 50 条
  • [1] Bioanalytical Method Development and Validation of Metaxalone in Human Plasma by LC-MS/MS
    Soni, Nirav R.
    Patel, Mandev B.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND ALLIED SCIENCES, 2015, 4 (03): : 100 - 108
  • [2] Bioanalytical method development and validation for quantification of amivantamab in rat plasma by LC-MS/MS
    Gaddey, Pridhvi Krishna
    Sundararajan, Raja
    FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES, 2024, 10 (01)
  • [3] Bioanalytical method development and validation for quantification of amivantamab in rat plasma by LC-MS/MS
    Pridhvi Krishna Gaddey
    Raja Sundararajan
    Future Journal of Pharmaceutical Sciences, 10
  • [4] Bioanalytical LC-MS/MS method validation for plasma determination of topiramate in healthy Indian volunteers
    Goswami, Dipanjan
    Kumar, Ajay
    Khuroo, Arshad H.
    Monif, Tausif
    Rab, Shamsur
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (11) : 1227 - 1241
  • [5] BIOANALYTICAL METHOD DEVELOPMENT AND METHOD VALIDATION IN HUMAN PLASMA BY USING LC MS/MS
    Patil, Rahul
    Bhaskar, Rajveer
    Ola, Monika
    Pingale, Diksha
    Chalikwar, Shailesh
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 6 (03): : 5176 - 5183
  • [6] Rapid and Sensitive Bioanalytical Method Development and Validation for Quantification of Metoprolol Using LC-MS/MS in Human Plasma
    Ishaq, Beludari Mohammed
    Reddy, Lingareddygari Siva Sanker
    Basha, Gajula Mahaboob
    Sreenivasulu, Munna
    Chetty, Challa Madhusudhana
    Ahad, Hindustan Abdul
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2020, 42 (02): : 171 - 179
  • [7] Anidulafungin-challenges in development and validation of an LC-MS/MS bioanalytical method validated for regulated clinical studies
    Alebic-Kolbah, Tanja
    Modesitt, Michael S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (6-7) : 2043 - 2055
  • [8] Bioanalytical method development and validation of novel antithrombotic agent S002-333 by LC-MS/MS and its application to pharmacokinetic studies
    Bhatta, R. S.
    Kumar, D.
    Chhonker, Y. S.
    Saxena, A. K.
    Jain, G. K.
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (11) : 1234 - 1239
  • [9] Method development and validation of cabozantinib by LC-MS/MS
    Venkateshwarlu, Punna
    Patel, Mehul M.
    PHARMACIA, 2022, 69 (02) : 407 - 413
  • [10] Bioanalytical method development, validation and quantification of dorsomorphin in rat plasma by LC-MS/MS
    Karthikeyan, K.
    Mahat, Mahamad Yunnus A.
    Chandrasekaran, S.
    Gopal, K.
    Franklin, P. X.
    Sivakumar, Balasubramanian Jaganatha
    Singh, Gajendra
    Narayanan, Shridhar
    Gopalan, B.
    Khan, Ansar A.
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (08) : 1018 - 1026