Study and application of the shift-temperature of heating fluid for zeotropic mixtures in Rankine

被引:4
|
作者
Bu, Shujuan [1 ]
Yang, Xinle [1 ]
Li, Weikang [1 ]
Su, Chang [1 ]
Wang, Xin [1 ]
Liu, Xunan [1 ]
Yu, Ning [1 ]
Wang, Guanyu [1 ]
Tang, Jupeng [2 ]
机构
[1] Liaoning Tech Univ, Sch Mech Engn, Fuxin 123000, Peoples R China
[2] Liaoning Tech Univ, Dev Ctr New Energy, Fuxin 123000, Peoples R China
关键词
Shift -temperature of heating fluid for zeotropic; mixtures; Entropy difference ratio of latent heat; Position of pinch point in the evaporator; Dry; Wet; And isentropic fluids; Matching between zeotropic mixtures and; heating fluid; PINCH POINT; WORKING FLUIDS; CYCLE SYSTEM; PERFORMANCE; SELECTION;
D O I
10.1016/j.icheatmasstransfer.2023.106808
中图分类号
O414.1 [热力学];
学科分类号
摘要
The theoretical formulations of the shift-temperature of the heating fluid for zeotropic mixtures (Tshift) were derived when the pinch point was located at the evaporating bubble point and the working fluid inlet of the evaporator, respectively, which were applicable to dry, wet, and isentropic zeotropic mixtures. Tshift was cor-rected by the impact factor analysis and calculated exactly using the Dragonfly algorithm. The optimal zeotropic mixture was matched by comparing the heat source temperature(Tg, in) and Tshift. The results indicate that Tshift is a property of every zeotropic mixture and is related to the critical temperature, the evaporation bubble point temperature, and the condensation dew point temperature. When the pinch point is at the evaporation bubble point, the zeotropic mixture with Tshift lower than Tg, in is selected and then combined with the thermal efficiency for a comprehensive evaluation. When the pinch point is at the working fluid inlet of the evaporator, Tshift is also affected by the pinch point temperature difference and the temperature glide of the condensation process, Tshift is significantly lower than Tg, in, all zeotropic mixtures are applied. Among the matched zeotropic mixtures, R227ea/R22 with the lowest Tshift has the best thermal performance in the ORC system.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Organic Rankine cycle-ejector heat pump hybrid system using low GWP zeotropic mixtures for trigeneration application
    Yaici, Wahiba
    Entchev, Evgueniy
    Longo, Michela
    ENERGY CONVERSION AND MANAGEMENT, 2024, 299
  • [22] Thermodynamic, Economic and Sustainability Analysis of Solar Organic Rankine Cycle System with Zeotropic Working Fluid Mixtures for Micro-Cogeneration in Buildings
    Yaici, Wahiba
    Entchev, Evgueniy
    Talebizadehsardari, Pouyan
    Longo, Michela
    APPLIED SCIENCES-BASEL, 2020, 10 (21): : 1 - 34
  • [23] Parametric optimization and performance analysis of zeotropic mixtures for an organic Rankine cycle driven by low-medium temperature geothermal fluids
    Kang, Zhenhua
    Zhu, Paling
    Lu, Xinli
    Li, Tailu
    Wu, Xiujie
    APPLIED THERMAL ENGINEERING, 2015, 89 : 323 - 331
  • [24] A study on optimal composition of zeotropic working fluid in an Organic Rankine Cycle (ORC) for low grade heat recovery
    Satanphol, K.
    Pridasawas, W.
    Suphanit, B.
    ENERGY, 2017, 123 : 326 - 339
  • [25] PERFORMANCE INVESTIGATION OF SOLAR ORGANIC RANKINE CYCLE SYSTEMS WITH AND WITHOUT REGENERATION AND WITH ZEOTROPIC WORKING FLUID MIXTURES FOR USE IN MICRO-COGENERATION
    Yaici, Wahiba
    Entchev, Evgueniy
    Sardari, Pouyan Talebizadeh
    PROCEEDINGS OF THE ASME 2020 14TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY (ES2020), 2020,
  • [26] Temperature drop of heating fluid as a primary condition for effective utilization of low-grade heat using flash cycles and zeotropic mixtures in refrigeration ejector systems
    Jakonczuk, Pawel
    Smierciew, Kamil
    Zou, Huiming
    Butrymowicz, Dariusz
    Dudar, Adam
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2025, 47 (01) : 4621 - 4639
  • [27] Temperature drop of heating fluid as a primary condition for effective utilization of low-grade heat using flash cycles and zeotropic mixtures in refrigeration ejector systems
    Jakonczuk, Pawel
    Smierciew, Kamil
    Zou, Huiming
    Butrymowicz, Dariusz
    Dudar, Adam
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2025, 47 (01) : 4621 - 4639
  • [28] Thermodynamic analysis and parametric optimization of ejector heat pump integrated with organic Rankine cycle combined cooling, heating and power system using zeotropic mixtures
    Zhu, Yilin
    Li, Weiyi
    Wang, Yongzhen
    Li, Haojie
    Li, Shuai
    APPLIED THERMAL ENGINEERING, 2021, 194
  • [29] Effects of heat source temperature and mixture composition on the combined superiority of dual-pressure evaporation organic Rankine cycle and zeotropic mixtures
    Li, Jian
    Ge, Zhong
    Duan, Yuanyuan
    Yang, Zhen
    ENERGY, 2019, 174 : 436 - 449
  • [30] Thermodynamic analysis of a modified cascade high temperature heat pump with zeotropic mixtures for heating production up to 200 °C
    Huang, Yisheng
    Li, Guiqiang
    Tang, Xin
    Huang, Kunteng
    Zhao, Wei
    Zhang, Jing
    ENERGY CONVERSION AND MANAGEMENT, 2025, 324