MoS2-ZnO Nanocomposite Mediated Immunosensor for Non-Invasive Electrochemical Detection of IL8 Oral Tumor Biomarker

被引:11
|
作者
Vetrivel, Cittrarasu [1 ,2 ]
Sivarasan, Ganesan [3 ]
Durairaj, Kaliannan [4 ]
Ragavendran, Chinnasamy [5 ]
Kamaraj, Chinnaperumal [6 ]
Karthika, Sankar [7 ]
Lo, Huang-Mu [3 ]
机构
[1] SSN Coll Engn Kalavakkam, Dept Chem Engn, Carbon Capture Lab, Chennai 603110, Tamil Nadu, India
[2] Saveetha Inst Med & Tech Sci, Saveetha Dent Coll & Hosp, Dept Anat, Chennai 600077, Tamil Nadu, India
[3] Chaoyang Univ Technol, Dept Environm Engn & Management, Taichung 41349, Taiwan
[4] Wonkwang Univ, Zoonosis Res Ctr, Sch Med, Dept Infect Biol, Iksan 54538, South Korea
[5] Saveetha Inst Med & Tech Sci, Saveetha Dent Coll & Hosp, Dept Conservat Dent & Endodont, Chennai 600077, Tamil Nadu, India
[6] SRM Inst Sci & Technol SRMIST, Interdisciplinary Inst Indian Syst Med IIISM, Directorate Res & Virtual Educ, Kattankulathur 603203, Tamil Nadu, India
[7] Mahendra Arts & Sci Coll Autonomous, Dept Biotechnol, Namakkal 637501, Tamil Nadu, India
关键词
immunosensor; molybdenum disulfide; zinc oxide nanoparticles; biomarkers; electrochemical biosensor; interleukin-8; oral cancer; HIGHLY SENSITIVE DETECTION; HUMAN SERUM; URIC-ACID; SENSOR; NANOPARTICLES; INTERLEUKIN-8; POLYMER; NANOSTRUCTURES; NANOMATERIALS; IMMUNOASSAYS;
D O I
10.3390/diagnostics13081464
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In order to support biomolecule attachment, an effective electrochemical transducer matrix for biosensing devices needs to have many specialized properties, including quick electron transfer, stability, high surface area, biocompatibility, and the presence of particular functional groups. Enzyme-linked immunosorbent assays, gel electrophoresis, mass spectrometry, fluorescence spectroscopy, and surface-enhanced Raman spectroscopy are common techniques used to assess biomarkers. Even though these techniques provide precise and trustworthy results, they cannot replace clinical applications because of factors such as detection time, sample amount, sensitivity, equipment expense, and the need for highly skilled individuals. For the very sensitive and targeted electrochemical detection of the salivary oral cancer biomarker IL8, we have created a flower-structured molybdenum disulfide-decorated zinc oxide composite on GCE (interleu-kin-8). This immunosensor shows very fast detection; the limit of detection (LOD) for interleukin-8 (IL8) detection in a 0.1 M phosphate buffer solution (PBS) was discovered to be 11.6 fM, while the MoS2/ZnO nanocomposite modified glassy carbon electrode (GCE) demonstrated a high catalytic current linearly from 500 pg to 4500 pg mL(-1) interleukin-8 (IL8). Therefore, the proposed biosensor exhibits excellent stability, high accuracy sensitivity, repeatability, and reproducibility and shows the acceptable fabrication of the electrochemical biosensors to detect the ACh in real sample analysis.
引用
收藏
页数:13
相关论文
共 4 条
  • [1] Silver molybdate nanoparticles based immunosensor for the non-invasive detection of Interleukin-8 biomarker
    Pachauri, Namrata
    Lakshmi, G. B. V. S.
    Sri, Smriti
    Gupta, Pramod K.
    Solanki, Pratima R.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 113
  • [2] Fabrication of nanomolecular platform based immunosensor for non-invasive electrochemical detection of oral cancer: An in vitro study
    Choudhary, Meenakshi
    Kumar, Vinay
    Parambath, Ashik Babu
    Caplash, Shruti
    Yadav, Birendra Kumar
    Kaur, Satbir
    Shah, Sapna Ratan
    Arora, Kavita
    TALANTA OPEN, 2024, 10
  • [3] The Reprimo-Like Gene Is an Epigenetic-Mediated Tumor Suppressor and a Candidate Biomarker for the Non-Invasive Detection of Gastric Cancer
    Alejandra Alarcon, Maria
    Olivares, Wilda
    Cordova-Delgado, Miguel
    Munoz-Medel, Matias
    de Mayo, Tomas
    Carrasco-Avino, Gonzalo
    Wichmann, Ignacio
    Landeros, Natalia
    Amigo, Julio
    Norero, Enrique
    Villarroel-Espindola, Franz
    Riquelme, Arnoldo
    Garrido, Marcelo
    Owen, Gareth, I
    Corvalan, Alejandro H.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (24) : 1 - 15
  • [4] Cubic CeO2 implanted reduced graphene oxide-based highly sensitive biosensor for non-invasive oral cancer biomarker detection
    Pachauri, Namrata
    Dave, Kashyap
    Dinda, Amit
    Solanki, Pratima R.
    JOURNAL OF MATERIALS CHEMISTRY B, 2018, 6 (19) : 3000 - 3012