Body composition profiling at 0.55T: Feasibility and precision

被引:3
|
作者
Nayak, Krishna S. [1 ,4 ]
Cui, Sophia X. [2 ]
Tasdelen, Bilal [1 ]
Yagiz, Ecrin [1 ]
Weston, Sarah [3 ]
Zhong, Xiaodong [2 ]
Ahlgren, Andre [3 ]
机构
[1] Univ Southern Calif, Elect & Comp Engn, Los Angeles, CA USA
[2] Siemens Med Solut USA, Los Angeles, CA USA
[3] AMRA Med, Linkoping, Sweden
[4] 3740 McClintock Ave,Suite 400C, Los Angeles, CA 90089 USA
基金
美国国家科学基金会;
关键词
0; 55; tesla; body composition MRI; low field; metabolic disease; obesity; screening; FAT; QUANTIFICATION; MR;
D O I
10.1002/mrm.29682
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeBody composition MRI captures the distribution of fat and lean tissues throughout the body, and provides valuable biomarkers of obesity, metabolic disease, and muscle disorders, as well as risk assessment. Highly reproducible protocols have been developed for 1.5T and 3T MRI. The purpose of this work was to demonstrate the feasibility and test-retest repeatability of MRI body composition profiling on a 0.55T whole-body system. MethodsHealthy adult volunteers were scanned on a whole-body 0.55T MRI system using the integrated body RF coil. Experiments were performed to refine parameter settings such as TEs, resolution, flip angle, bandwidth, acceleration, and oversampling factors. The final protocol was evaluated using a test-retest study with subject removal and replacement in 10 adult volunteers (5 M/5F, age 25-60, body mass index 20-30). ResultsCompared to 1.5T and 3T, the optimal flip angle at 0.55T was higher (15 degrees), due to the shorter T1 times, and the optimal echo spacing was larger, due to smaller chemical shift between water and fat. Overall image quality was comparable to conventional field strengths, with no significant issues with fat/water swapping or inadequate SNR. Repeatability coefficient of visceral fat, subcutaneous fat, total thigh muscle volume, muscle fat infiltration, and liver fat were 11.8 cL (2.2%), 46.9 cL (1.9%), 14.6 cL (0.5%), 0.1 pp (2%), and 0.2 pp (5%), respectively (coefficient of variation in parenthesis). ConclusionsWe demonstrate that 0.55T body composition MRI is feasible and present optimized scan parameters. The resulting images provide satisfactory quality for automated post-processing and produce repeatable results.
引用
收藏
页码:1114 / 1120
页数:7
相关论文
共 50 条
  • [1] Diffusion tensor brain imaging at 0.55T: A feasibility study
    Kung, Hao-Ting
    Cui, Sophia X.
    Kaplan, Jonas T.
    Joshi, Anand A.
    Leahy, Richard M.
    Nayak, Krishna S.
    Haldar, Justin P.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1649 - 1657
  • [2] 3D MR elastography at 0.55T: Concomitant field effects and feasibility
    Darwish, Omar Isam
    Di Cio, Pierluigi
    Sinkus, Ralph
    Neji, Radhouene
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (04) : 1602 - 1614
  • [3] Clinical feasibility of MRI-guided in-bore prostate biopsies at 0.55T
    Kaur, Tejinder
    Jiang, Yun
    Seiberlich, Nicole
    Hussain, Hero
    Wells, Shane
    Wei, John
    Caoili, Elaine
    Gulani, Vikas
    ABDOMINAL RADIOLOGY, 2025,
  • [4] Improved abdominal T1 weighted imaging at 0.55T
    Tasdelen, Bilal
    Lee, Nam G.
    Cui, Sophia X.
    Nayak, Krishna S.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (06) : 2580 - 2587
  • [5] Evaluation of Tracheomalacia Using Novel 0.55T MRI
    Kapai, S.
    Kumar, P.
    Yagiz, E.
    Kato, R. M.
    Tian, Y.
    Lee, N. G.
    Chen, M.
    Ferrada, M.
    Campbell-Washburn, A. E.
    Nayak, K. S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [6] Improved abdominal T1 weighted imaging at 0.55T
    Tasdelen, Bilal
    Lee, Nam G.
    Cui, Sophia X.
    Nayak, Krishna S.
    MAGNETIC RESONANCE IN MEDICINE, 2024,
  • [7] Fully automated planning for anatomical fetal brain MRI on 0.55T
    Silva, Sara Neves
    Mcelroy, Sarah
    Verdera, Jordina Aviles
    Colford, Kathleen
    St Clair, Kamilah
    Tomi-Tricot, Raphael
    Uus, Alena
    Ozenne, Valery
    Hall, Megan
    Story, Lisa
    Pushparajah, Kuberan
    Rutherford, Mary A.
    Hajnal, Joseph V.
    Hutter, Jana
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (03) : 1263 - 1276
  • [8] An interventional MRI guidewire combining profile and tip conspicuity for catheterization at 0.55T
    Yildirim, Dursun Korel
    Uzun, Dogangun
    Bruce, Christopher G.
    Khan, Jaffar M.
    Rogers, Toby
    Schenke, William H.
    Ramasawmy, Rajiv
    Campbell-Washburn, Adrienne
    Herzka, Daniel A.
    Lederman, Robert J.
    Kocaturk, Ozgur
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (02) : 845 - 858
  • [9] Characterizing T1 in the fetal brain and placenta over gestational age at 0.55T
    Aviles Verdera, Jordina
    Tomi-Tricot, Raphael
    Story, Lisa
    Rutherford, Mary A.
    Ourselin, Sebastien
    Hajnal, Joseph V.
    Malik, Shaihan J.
    Hutter, Jana
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (05) : 2101 - 2111
  • [10] Simultaneous multi-slice cardiac real-time MRI at 0.55T
    Yagiz, Ecrin
    Garg, Parveen
    Cen, Steven Y.
    Nayak, Krishna S.
    Tian, Ye
    MAGNETIC RESONANCE IN MEDICINE, 2024,