Early Results of the Newly-Designed Flowdynamics Dense Mesh Stent for Residual Dissection After Proximal Repair of Stanford Type A or Type B Aortic Dissection: A Preliminary Single-Center Report From a Multicenter, Prospective, and Randomized Study

被引:1
|
作者
Lu, Chen [1 ]
Wang, Haiyue [1 ]
Yang, Peng [1 ]
Liu, Yu [1 ]
Zhang, Yu [1 ]
Xu, Zhenyuan [1 ]
Xie, Yi [1 ]
Hu, Jia [1 ,2 ,3 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Cardiovasc Surg, Chengdu, Peoples R China
[2] Sichuan Univ, Guangan Hosp, West China Hosp, Dept Cardiothorac Surg, Guangan, Peoples R China
[3] Sichuan Univ, West China Hosp, Dept Cardiovasc Surg, GuoXue Alley 37, Chengdu 610041, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
aortic dissection; flowdynamics dense mesh stent; MULTILAYER FLOW MODULATOR; TOTAL ARCH REPLACEMENT; LONG-TERM OUTCOMES; DEBAKEY TYPE-I; ENDOVASCULAR REPAIR; ANEURYSMS; MANAGEMENT; SURGERY; GRAFT;
D O I
10.1177/15266028231163057
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Negative remodeling of the distal aorta due to residual dissection significantly impacts the long-term outcomes of dissection patients after proximal repair of acute aortic dissection. Branched/fenestrated aortic stents are technically demanding, and studies of the first generation of multilayer flow modulators for tackling this clinical scenario are few and limited. The single-center results from a multicenter, prospective, and randomized controlled study aimed to verify the safety and effectiveness of a newly-designed flowdynamics dense mesh stent for treating residual dissection after proximal repair. Methods: Patients with nonchronic residual dissection involving visceral branches were prospectively enrolled in 3 centers (ChiCTR1900023638). Eligible patients were randomly assigned to the flowdynamics dense mesh stent (FDMS) group and control group. Follow-up visits were arranged at 1, 3, 6, and 12 months after recruitment. The primary endpoints were all-cause and aortic-related mortality. The secondary endpoints included visceral branch occlusion, reintervention, and severe adverse events. Morphological changes were analyzed to exhibit the therapeutic effect. Our center participated in the multicenter prospective randomized controlled trial, and the preliminary single-center experience was reported. Results: Thirty-six patients were enrolled in our center, and the baseline characteristics of the 2 groups were comparable. Thirty-four patients completed the 12 month follow-up. Freedom from all-cause and aortic-related death were 94.4% and 100%. All visceral branches remained patent in the FDMS group. Increased area of the true lumen (1.03 +/- 0.38 vs 0.48 +/- 0.63 cm(2) at the plane below renal arteries, p=0.006; 1.27 +/- 0.80 vs 0.32 +/- 0.50 cm(2) at the plane 5 cm below renal arteries, p<0.001) and decreased area of the false lumen at the plane below renal arteries (-1.03 +/- 0.84 vs -0.15 +/- 1.21 cm(2), p=0.023) were observed in the FDMS group compared with those parameters in the control group. The FDMS group showed a significant increase in true lumen volume (p<0.001) and a significant decrease in false lumen volume (p=0.018). Conclusions: This newly-designed FDMS for endovascular repair of residual dissection after the proximal repair is safe and effective at 12 months. Clinical Impact One-year results of the randomized controlled clinical trial indicated the short-term safety and promising effect of FDMS on treating non-chronic residual dissection after proximal repair. At the 12th-month follow-up, the true lumen expanded, the false lumen shrunk and all visceral arteries kept patent. As far as I'm concerned, this is the first randomized controlled study concerning utilizing multilayer flow mesh stent treating aortic dissection. Despite a preliminary single-center report, our results are supposed to provide high-quality evidence to guide clinical practice and fill the gap in the application of FDMS.
引用
收藏
页码:984 / 994
页数:11
相关论文
共 5 条
  • [1] One-year results of the Flowdynamics Dense Mesh Stent for residual dissection after proximal repair of stanford type A or type B aortic dissection: a multicenter, prospective, and randomized study
    Lu, Chen
    Duan, Weixun
    Li, Zhen
    Wang, Chenhao
    Yang, Peng
    Liu, Yu
    Zuo, Jian
    Hu, Jia
    INTERNATIONAL JOURNAL OF SURGERY, 2024, 110 (07) : 4151 - 4160
  • [2] Long-term results of type B aortic dissection patients with tumor after endovascular repair or optimal medical therapy: a single-center and retrospective cohort study
    Liang, Taiping
    Zhu, Hongqiao
    Zhang, Lei
    Li, Shuangshuang
    He, Xiaomin
    Zhao, Kaiwen
    Jing, Zaiping
    Zhou, Jian
    BMC SURGERY, 2021, 21 (01)
  • [3] A novel open-vascular single-branched stent graft in total arch repair of type a aortic dissection one-year results of a prospective multicenter randomized controlled study
    Gu, Jiawei
    Zhang, Weize
    Kang, Le
    Sun, Yongxin
    Li, Jun
    Wang, Yulin
    Ji, Qiang
    Lu, Shuyang
    Zhai, Junyu
    Huang, Ben
    Zhu, Kai
    Liu, Dingqian
    Lai, Hao
    Wang, Chunsheng
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2025, 431
  • [4] Impact on early outcome after endovascular repair of type B dissection without proximal landing zone using Castor single-branched stent graft-a retrospective cohort study
    Cheng, Zhang
    Zhang, Hongbo
    Pu, Junzhou
    Schoenhagen, Paul
    Zhao, Lei
    Qiao, Huanyu
    Yang, Bo
    Wu, Wenhui
    Zhang, Chen
    Wang, Ruihai
    Liu, Yongmin
    Ma, Xiaohai
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2024, 14 (01) : 18 - 28
  • [5] Long-term results of type B aortic dissection patients with tumor after endovascular repair or optimal medical therapy: a single—center and retrospective cohort study
    Taiping Liang
    Hongqiao Zhu
    Lei Zhang
    Shuangshuang Li
    Xiaomin He
    Kaiwen Zhao
    Zaiping Jing
    Jian Zhou
    BMC Surgery, 21