Comparison of the carotid corrected flow time and tidal volume challenge for assessing fluid responsiveness in robot-assisted laparoscopic surgery

被引:5
|
作者
Tang, Xixi [1 ]
Chen, Qi [1 ]
Huang, Zejun [2 ]
Liang, Jingqiu [3 ]
An, Ran [1 ]
Liu, Hongliang [1 ]
机构
[1] Chongqing Univ, Dept Anesthesiol, Canc Hosp, Chongqing, Peoples R China
[2] Chongqing Univ, Dept Ultrasound, Canc Hosp, Chongqing, Peoples R China
[3] Chongqing Univ, Chongqing Canc Multi Big Data Applicat Engn Res Ct, Canc Hosp, Chongqing, Peoples R China
关键词
Carotid corrected flow time; Doppler ultrasound; Tidal volume challenge; Fluid responsiveness; Robotics; Laparoscopic surgery; PULSE PRESSURE VARIATION; MECHANICALLY VENTILATED PATIENTS; RESPIROPHASIC VARIATION; CARDIAC-OUTPUT; ARTERY; ULTRASONOGRAPHY;
D O I
10.1007/s11701-023-01710-y
中图分类号
R61 [外科手术学];
学科分类号
摘要
We aimed to compare the ability of carotid corrected flow time assessed by ultrasound and the changes in dynamic preload indices induced by tidal volume challenge predicting fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery in the modified head-down lithotomy position. This prospective single-center study included patients undergoing robot-assisted laparoscopic surgery in the modified head-down lithotomy position. Carotid Doppler parameters and hemodynamic data, including corrected flow time, pulse pressure variation, stroke volume variation, and stroke volume index at a tidal volume of 6 mL/kg predicted body weight and after increasing the tidal volume to 8 mL/kg predicted body weight (tidal volume challenge), respectively, were measured. Fluid responsiveness was defined as a stroke volume index >= 10% increase after volume expansion. Among the 52 patients included, 26 were classified as fluid responders and 26 as non-responders based on the stroke volume index. The area under the receiver operating characteristic curve measured to predict the fluid responsiveness to corrected flow time and changes in pulse pressure variation (Delta PPV6-8) after tidal volume challenge were 0.82 [95% confidence interval (CI) 0.71-0.94; P < 0.0001] and 0.85 (95% CI 0.74-0.96; P < 0.0001), respectively. The value for pulse pressure variation at a tidal volume of 8 mL/kg was 0.79 (95% CI 0.67-0.91; P = 0.0003). The optimal cut-off values for corrected flow time and Delta PPV6-8 were 357 ms and > 1%, respectively. Both the corrected flow time and Changes in pulse pressure variation after tidal volume challenge reliably predicted fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery in the modified head-down lithotomy position. And pulse pressure variation at a tidal volume of 8 mL/kg maybe also a useful predictor.Trial registration: Chinese Clinical Trial Register (CHiCTR2200060573, Principal investigator: Hongliang Liu, Date of registration: 05/06/2022). Trial registration: Chinese Clinical Trial Register (CHiCTR2200060573, Principal investigator: Hongliang Liu, Date of registration: 05/06/2022).
引用
收藏
页码:2763 / 2772
页数:10
相关论文
共 28 条
  • [21] Evaluating corrected carotid flow time as a non-invasive parameter for trending cardiac output and stroke volume in cardiac surgery patients
    van Houte, Joris
    Raaijmaakers, Anniek E.
    Mooi, Frederik J.
    Meijs, Loek P. B.
    de Boer, Esmee C.
    Suriani, Irene
    Houterman, Saskia
    Montenij, Leon J.
    Bouwman, Arthur R.
    JOURNAL OF ULTRASOUND, 2023, 26 (01) : 89 - 97
  • [22] Usefulness of blood flow evaluation by indocyanine green fluorescence in laparoscopic or robot-assisted surgery for colorectal cancer with persistent descending mesocolon
    Kusafuka, Hiroshi
    Hiraki, Masayuki
    Kawai, Kenji
    Ikeshima, Ryo
    Hata, Taishi
    Yanagisawa, Kiminori
    Kinoshita, Mitsuru
    Katsuyama, Shinsuke
    Shinke, Go
    Ohmura, Yoshiaki
    Sugimura, Keijiro
    Masuzawa, Toru
    Takeda, Yutaka
    Murata, Kohei
    ASIAN JOURNAL OF ENDOSCOPIC SURGERY, 2023, 16 (04) : 804 - 808
  • [23] The predictive ability of carotid artery corrected flow time and respirophasic variation in blood flow peak velocity measured by ultrasonography for fluid responsiveness in parturients for cesarean delivery
    Xu, Lili
    Dai, Shaobing
    Shen, Jianjun
    Lv, Changcheng
    Tang, Yuwen
    Chen, Xinzhong
    MINERVA ANESTESIOLOGICA, 2020, 86 (10) : 1039 - 1046
  • [24] Evaluating corrected carotid flow time as a non-invasive parameter for trending cardiac output and stroke volume in cardiac surgery patients
    Joris van Houte
    Anniek E. Raaijmaakers
    Frederik J. Mooi
    Loek P. B. Meijs
    Esmée C. de Boer
    Irene Suriani
    Saskia Houterman
    Leon J. Montenij
    Arthur R. Bouwman
    Journal of Ultrasound, 2023, 26 : 89 - 97
  • [25] Comparison of laparoscopic versus robot-assisted sugery for rectal cancer after neo-adjuvant therapy: a large volume single center experience
    Zhu, Heyuan
    Zou, Jingyu
    Pan, Hongfeng
    Huang, Ying
    Chi, Pan
    BMC SURGERY, 2025, 25 (01)
  • [26] Letter to the editor on: "Effect of different targets of goal-directed fluid therapy on intraoperative hypotension and fluid infusion in robot-assisted laparoscopic gynecological surgery: a randomized non-inferiority trial"
    Satici, Muhammed Halit
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [27] A comparison of transcutaneous Doppler corrected flow time, b-type natriuretic peptide and central venous pressure as predictors of fluid responsiveness in septic shock: a preliminary evaluation.
    Sturgess, D. J.
    Pascoe, R. L. S.
    Scalia, G.
    Venkatesh, B.
    ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (02) : 336 - 341
  • [28] Comparison of short-term outcomes between robot-assisted and laparoscopic rectal surgery for rectal cancer: A propensity score-matched analysis using the Japanese Nationwide diagnosis procedure combination database
    Mizoguchi, Masako
    Kizuki, Masashi
    Iwata, Noriko
    Tokunaga, Masanori
    Fushimi, Kiyohide
    Kinugasa, Yusuke
    Fujiwara, Takeo
    ANNALS OF GASTROENTEROLOGICAL SURGERY, 2023, 7 (06): : 955 - 967