Hypergravity stimulates mechanical behavior and micro-architecture of tibia in rats

被引:0
|
作者
Gao, Lilan [1 ,2 ]
Chen, Ruiqi [1 ,2 ]
Liu, Jin [1 ,2 ]
Tan, Yansong [1 ,2 ]
Gao, Qijun [1 ,2 ]
Zhang, Chunqiu [1 ,2 ]
Lv, Linwei [1 ,2 ]
机构
[1] Tianjin Univ Technol, Tianjin Key Lab Adv Mechatron Syst Design & Intell, Sch Mech Engn, Tianjin 300384, Peoples R China
[2] Tianjin Univ Technol, Natl Demonstrat Ctr Expt Mech & Elect Engn Educ, Tianjin 300384, Peoples R China
基金
中国国家自然科学基金;
关键词
High plus G; Tibia; Mechanical property; Micro-architecture; Cellular metabolism; SKELETAL STRUCTURAL ADAPTATIONS; REDEFINING WOLFF LAW; BONE-MINERAL DENSITY; USAGE SATMU; IMMUNE-SYSTEM; SPACEFLIGHT; ENVIRONMENT; MODULATION; RESPONSES; EXPOSURE;
D O I
10.1007/s00774-023-01481-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionThe bone tissue is susceptible to hypergravity (+ G) environment. It is necessary to discuss the extent to which specific + G values are beneficial or detrimental to bone tissue. The objective of this study was to characterize the effects of high + G values on mechanical properties, microstructures, and cellular metabolism of bone.Materials and methods30 male Wistar rats aged 12 weeks were randomly divided into 5 groups, and bore different + G (namely + 1G, + 4G, + 8G, + 10G and + 12G) environments respectively for 4 weeks, 5 days each week, and 3 minutes each day. The macro-mechanical parameters, microstructure parameters, and mRNA transcription levels of the tibia were determined through the three-point bending method, micro-CT detection, and q-PCR analysis, respectively.ResultsAs the + G value increases, hypergravity becomes increasingly detrimental to the macro-mechanical performance of rat tibia. Concerning the microstructure of cancellous bone, there appears to be a favorable trend at + 4G, followed by a progressively detrimental trend at higher G values. In addition, the mRNA transcription levels of OPG and RANKL show an initial tendency of enhanced bone absorption at +4G, followed by an increase in bone remodeling capacity as G value increases.ConclusionThe higher G values correspond to poorer macro-mechanical properties of the tibia, and a + 4G environment benefits the microstructure of the tibia. At the cellular level, bone resorption is enhanced in the + 4G group, but the bone remodeling capability gradually increases with further increments in G values.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 50 条
  • [1] Hypergravity stimulates mechanical behavior and micro-architecture of tibia in rats
    Lilan Gao
    Ruiqi Chen
    Jin Liu
    Yansong Tan
    Qijun Gao
    Chunqiu Zhang
    Linwei Lv
    Journal of Bone and Mineral Metabolism, 2024, 42 : 17 - 26
  • [2] Site-specific variation of bone micro-architecture in the distal radius and tibia
    Boyd, Steven K.
    JOURNAL OF CLINICAL DENSITOMETRY, 2008, 11 (03) : 424 - 430
  • [3] Micro-architecture Under Perspective of Landscape
    Yuan Haibeibei
    Kong Yuhang
    ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 3841 - +
  • [4] The micro-architecture of the cerebral cortex: Functional neuroimaging models and metabolism
    Riera, Jorge J.
    Schousboe, Arne
    Waagepetersen, Helle S.
    Howarth, Clare
    Hyder, Fahmeed
    NEUROIMAGE, 2008, 40 (04) : 1436 - 1459
  • [5] A novel high symmetry interlocking micro-architecture design for polymer composites with improved mechanical properties
    Haldar, Sandip
    Sain, Trisha
    Ghosh, Susanta
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2017, 124 : 161 - 175
  • [6] Luminescent Lotuses: Mimesis in Mihrabs and Micro-architecture at Makli
    Quraishi, Fatima
    PHILOLOGICAL ENCOUNTERS, 2022, 7 (1-2) : 55 - 94
  • [7] Micro-architecture study of the normal odontoid with micro-computed tomography
    Wang, Wei
    Li, Zhijun
    Qi, Yingna
    Chen, Lianxiang
    Yi, Ping
    Yang, Feng
    Tang, Xiangsheng
    Tan, Mingsheng
    JOURNAL OF SPINAL CORD MEDICINE, 2020, 43 (02) : 211 - 216
  • [8] Exploiting dynamic micro-architecture usage in gate sizing
    Roy, Sanghamitra
    Chakraborty, Koushik
    MICROPROCESSORS AND MICROSYSTEMS, 2011, 35 (04) : 417 - 425
  • [9] Research and Implementation of Micro-Architecture for Elliptic Curve Cryptography Processor
    Li Miao
    Yang Xiaohui
    Dai Zibin
    Chen Tao
    He Liangsheng
    2011 INTERNATIONAL CONFERENCE OF ELECTRON DEVICES AND SOLID-STATE CIRCUITS (EDSSC), 2011,
  • [10] Micro-architecture optimization of THUMP105 SOC implementation
    Zhang, S
    Yang, Q
    Zhou, RD
    2004: 7TH INTERNATIONAL CONFERENCE ON SOLID-STATE AND INTEGRATED CIRCUITS TECHNOLOGY, VOLS 1- 3, PROCEEDINGS, 2004, : 1376 - 1379