Analysing Sources of Error in Total Internal Reflection Microscopy (TIRM) Experiments and Data Analysis

被引:1
|
作者
Rivera-Moran, J. Alejandro [1 ]
Lang, Peter R. [1 ]
机构
[1] Forschungszentrum Julich, IBI 4, D-52425 Julich, Germany
关键词
total internal reflection microscopy (TIRM); colloidal interaction; Brownian dynamics; hydrodynamic interaction; SURFACE FORCES APPARATUS; COLLOIDAL FORCES; HINDERED DIFFUSION; BROWNIAN-MOTION; VISCOUS-FLUID; SPHERE; WALL; PARTICLE; INTERFACE; DYNAMICS;
D O I
10.3390/polym15214208
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Many phenomena observed in synthetic and biological colloidal suspensions are dominated by the static interaction energies and the hydrodynamic interactions that act both between individual particles and also between colloids and macroscopic interfaces. This calls for methods that allow precise measurements of the corresponding forces. One method used for this purpose is total internal reflection microscopy (TIRM), which has been employed for around three decades to measure in particular the interactions between a single particle suspended in a liquid and a solid surface. However, given the importance of the observable variables, it is crucial to understand the possibilities and limitations of the method. In this paper, we investigate the influence of technically unavoidable noise effects and an inappropriate choice of particle size and sampling time on TIRM measurement results. Our main focus is on the measurement of diffusion coefficients and drift velocities, as the influence of error sources on dynamic properties has not been investigated so far. We find that detector shot noise and prolonged sampling times may cause erroneous results in the steep parts of the interaction potential where forces of the order of pico-Newtons or larger act on the particle, while the effect of background noise is negligible below certain thresholds. Furthermore, noise does not significantly affect dynamic data but we find that lengthy sampling times and/or probe particles with too small a radius will cause issues. Most importantly, we observe that dynamic results are very likely to differ from the standard hydrodynamic predictions for stick boundary conditions due to partial slip.
引用
收藏
页数:19
相关论文
共 35 条
  • [31] A Membrane-Bound FRET-Based Caspase Sensor for Detection of Apoptosis Using Fluorescence Lifetime and Total Internal Reflection Microscopy
    Angres, Brigitte
    Steuer, Heiko
    Weber, Petra
    Wagner, Michael
    Schneckenburger, Herbert
    CYTOMETRY PART A, 2009, 75A (05) : 420 - 427
  • [32] Autocalibrated Scanning-Angle Prism-Type Total Internal Reflection Fluorescence Microscopy for Nanometer-Precision Axial Position Determination
    Sun, Wei
    Marchuk, Kyle
    Wang, Gufeng
    Fang, Ning
    ANALYTICAL CHEMISTRY, 2010, 82 (06) : 2441 - 2447
  • [33] Single-Molecule Imaging of Lateral Mobility and Ion Channel Activity in Lipid Bilayers using Total Internal Reflection Fluorescence (TIRF) Microscopy
    Wang, Shuo
    Nussberger, Stephan
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (192):
  • [34] Threshold-free evaluation of near-surface diffusion and adsorption-dominated motion from single-molecule tracking data of single-stranded DNA through total internal reflection fluorescence microscopy
    Hanasaki, Itsuo
    Uehara, Satoshi
    Arai, Yoshiyuki
    Nagai, Takeharu
    Kawano, Satoyuki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2015, 54 (12)
  • [35] Multivariate Analysis of Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) Spectroscopic Data to Confirm Phase Partitioning in Methacrylate-Based Dentin Adhesive
    Ye, Qiang
    Parthasarathy, Ranganathan
    Abedin, Farhana
    Laurence, Jennifer S.
    Misra, Anil
    Spencer, Paulette
    APPLIED SPECTROSCOPY, 2013, 67 (12) : 1473 - 1478