Analysing Sources of Error in Total Internal Reflection Microscopy (TIRM) Experiments and Data Analysis

被引:1
|
作者
Rivera-Moran, J. Alejandro [1 ]
Lang, Peter R. [1 ]
机构
[1] Forschungszentrum Julich, IBI 4, D-52425 Julich, Germany
关键词
total internal reflection microscopy (TIRM); colloidal interaction; Brownian dynamics; hydrodynamic interaction; SURFACE FORCES APPARATUS; COLLOIDAL FORCES; HINDERED DIFFUSION; BROWNIAN-MOTION; VISCOUS-FLUID; SPHERE; WALL; PARTICLE; INTERFACE; DYNAMICS;
D O I
10.3390/polym15214208
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Many phenomena observed in synthetic and biological colloidal suspensions are dominated by the static interaction energies and the hydrodynamic interactions that act both between individual particles and also between colloids and macroscopic interfaces. This calls for methods that allow precise measurements of the corresponding forces. One method used for this purpose is total internal reflection microscopy (TIRM), which has been employed for around three decades to measure in particular the interactions between a single particle suspended in a liquid and a solid surface. However, given the importance of the observable variables, it is crucial to understand the possibilities and limitations of the method. In this paper, we investigate the influence of technically unavoidable noise effects and an inappropriate choice of particle size and sampling time on TIRM measurement results. Our main focus is on the measurement of diffusion coefficients and drift velocities, as the influence of error sources on dynamic properties has not been investigated so far. We find that detector shot noise and prolonged sampling times may cause erroneous results in the steep parts of the interaction potential where forces of the order of pico-Newtons or larger act on the particle, while the effect of background noise is negligible below certain thresholds. Furthermore, noise does not significantly affect dynamic data but we find that lengthy sampling times and/or probe particles with too small a radius will cause issues. Most importantly, we observe that dynamic results are very likely to differ from the standard hydrodynamic predictions for stick boundary conditions due to partial slip.
引用
收藏
页数:19
相关论文
共 35 条
  • [21] Total Internal Reflection Fluorescence Microscopy of Cell Adhesion on Patterned Self-Assembled Monolayers on Gold
    Hoover, Diana K.
    Lee, Eun-Ju
    Yousaf, Muhammad N.
    LANGMUIR, 2009, 25 (05) : 2563 - 2566
  • [22] Artifact-free objective-type multicolor total internal reflection fluorescence microscopy with light-emitting diode light sources-Part I
    Kogel, Alexander
    Kalwa, Hermann
    Urban, Nicole
    Schaefer, Michael
    JOURNAL OF BIOPHOTONICS, 2019, 12 (11)
  • [23] Uniform Total Internal Reflection Fluorescence Illumination Enables Live Cell Fluorescence Resonance Energy Transfer Microscopy
    Lin, Jia
    Hoppe, Adam D.
    MICROSCOPY AND MICROANALYSIS, 2013, 19 (02) : 350 - 359
  • [24] Single-particle spectroscopy and defocused imaging of anisotropic gold nanorods by total internal reflection scattering microscopy
    Lee, Jaeran
    Kim, Geun Wan
    Ha, Ji Won
    ANALYST, 2020, 145 (18) : 6038 - 6044
  • [25] Total internal reflection fluorescence microscopy imaging-guided confocal single-molecule fluorescence spectroscopy
    Zheng, Desheng
    Kaldaras, Leonora
    Lu, H. Peter
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (01)
  • [26] A total internal reflection fluorescence microscopy study of mass diffusion enhancement in water-based alumina nanofluids
    Veilleux, Jocelyn
    Coulombe, Sylvain
    JOURNAL OF APPLIED PHYSICS, 2010, 108 (10)
  • [27] Subcellular and single-molecule imaging of plant fluorescent proteins using total internal reflection fluorescence microscopy (TIRFM)
    Vizcay-Barrena, Gema
    Webb, Stephen E. D.
    Martin-Fernandez, Marisa L.
    Wilson, Zoe A.
    JOURNAL OF EXPERIMENTAL BOTANY, 2011, 62 (15) : 5419 - 5428
  • [28] Live Imaging of Cellular Internalization of Single Colloidal Particle by Combined Label-Free and Fluorescence Total Internal Reflection Microscopy
    Byrne, Gerard D.
    Vllasaliu, Driton
    Falcone, Franco H.
    Somekh, Michael G.
    Stolnik, Snjezana
    MOLECULAR PHARMACEUTICS, 2015, 12 (11) : 3862 - 3870
  • [29] Variable-angle total internal reflection fluorescence microscopy (VA-TIRFM): realization and application of a compact illumination device
    Stock, K
    Sailer, R
    Strauss, WSL
    Lyttek, M
    Steiner, R
    Schneckenburger, H
    JOURNAL OF MICROSCOPY, 2003, 211 : 19 - 29
  • [30] Theoretical background of light-emitting diode total internal reflection fluorescence microscopy and photobleaching lifetime analysis of membrane-associated proteins-Part II
    Schaefer, Michael
    Kalwa, Hermann
    JOURNAL OF BIOPHOTONICS, 2020, 13 (04)