A Comparison of Retrospective ECG-Gated CT and Surgical or Angiographical Findings in Acute Aortic Syndrome

被引:1
|
作者
Orii, Makoto [1 ,6 ]
Sone, Misato [1 ]
Fujiwara, Jumpei [2 ]
Sasaki, Tadashi [3 ]
Chiba, Takuya [3 ]
Kin, Hajime [4 ]
Morino, Yoshihiro [2 ]
Tanaka, Ryoichi [5 ]
Yoshioka, Kunihiro [1 ]
机构
[1] Iwate Med Univ, Dept Radiol, Yahaba, Japan
[2] Iwate Med Univ, Dept Internal Med, Div Cardiol, Yahaba, Japan
[3] Iwate Med Univ, Ctr Radiol Sci, Yahaba, Japan
[4] Iwate Med Univ, Dept Cardiovasc Surg, Yahaba, Japan
[5] Iwate Med Univ, Dept Reconstruct Oral & Maxillofacial Surg, Div Dent Radiol, Yahaba, Japan
[6] Iwate Med Univ, Dept Radiol, 2-1-1 Idaidori, Yahaba, Iwate 0283695, Japan
基金
日本学术振兴会;
关键词
Aortic dissection; Intimal tear; Intramural hematoma; Ulcer-like projection; PATENT FALSE LUMEN; INTERNATIONAL REGISTRY; COMPUTED-TOMOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; INTRAMURAL HEMATOMA; DIAGNOSTIC-ACCURACY; DISSECTION; MANAGEMENT; OUTCOMES; REPAIR;
D O I
10.1536/ihj.23-002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The best cardiac phases in retrospective ECG-gated CT for detecting an intimal tear (IT) in aortic dissection (AD) and an ulcer-like projection (ULP) in an intramural hematoma (IMH) have not been established. This study aimed to compare the detection accuracy of diastolic-phase and systolic-phase ECG-gated CT for IT in AD and ULP in IMH, with subsequent surgical or angiographical confirmation as the reference standard.In total, 81 patients (67.6 +/- 11.8 years; 41 men) who underwent emergency ECG-gated CT and subsequent open surgery or thoracic endovascular aortic repair for AD (n = 52) or IMH (n = 29) were included. The accuracies of detecting IT and ULP were compared among only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase methods of retrospective ECG-gated CT; surgical or angiographical findings were used as the reference standard. The detection accuracy for IT and ULP using only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase methods of ECG-gated CT was 93% [95% CI: 87-971, 94% [95% CI: 88-971, and 95% [95% CI: 90-971, respectively. There were no significant differences in detection accuracy among the 3 acquisition methods (P = 0.55). Similarly, there were no significant differences in the accuracy of detecting IT in AD (P = 0.55) and ULP in IMH (P > 0.99) among only diastolic-phase, only systolic-phase, and both diastolic-and systolic-phase ECG-gated CT.Retrospective ECG-gated CT for detecting IT in AD and ULP in IMH yields highly accurate findings. There were no significant differences seen among only diastolic-phase, only systolic-phase, and both diastolic -phase and systolic-phase ECG-gated CT.
引用
收藏
页码:839 / 846
页数:8
相关论文
共 50 条
  • [41] Can left ventricular end-diastolic volumes be estimated with prospective ECG-gated CT coronary angiography?
    Khatri, Prateek J.
    Tandon, Vikas
    Chen, Li
    Yam, Yeung
    Chow, Benjamin J. W.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (02) : 226 - 229
  • [42] ECG-gated computed tomography: a new role for patients with suspected aortic prosthetic valve endocarditis
    Fagman, Erika
    Perrotta, Sossio
    Bech-Hanssen, Odd
    Flinck, Agneta
    Lamm, Carl
    Olaison, Lars
    Svensson, Gunnar
    EUROPEAN RADIOLOGY, 2012, 22 (11) : 2407 - 2414
  • [43] Preliminary experience in the assessment of aortic valve calcification by ECG-gated multislice spiral computed tomography
    Koos, R
    Mahnken, AH
    Sinha, AM
    Wildberger, JE
    Hoffmann, R
    Kühl, HP
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 102 (02) : 195 - 200
  • [44] Low radiation dose ECG-gated chest CT angiography on a 256-slice multidetector CT scanner
    Tariq A. Hameed
    Shawn D. Teague
    Mani Vembar
    Ekta Dharaiya
    Jonas Rydberg
    The International Journal of Cardiovascular Imaging, 2009, 25 : 267 - 278
  • [45] A potential role of ECG-gated CT for the diagnosis of pulmonary vein thrombus: an illustrative case report
    Winkler, Michael A.
    von Herrmann, Paul
    Penticuff, Ryan H.
    Majmudar, Palak M.
    Plaisance, Benjamin R.
    Hobbs, Stephen B.
    Brooks, Michael A.
    CLINICAL IMAGING, 2015, 39 (03) : 513 - 515
  • [46] Prospective ECG-gated 320-row CT angiography of the whole aorta and coronary arteries
    Li, Yu
    Fan, Zhanming
    Xu, Lei
    Yang, Lin
    Xin, Haiyan
    Zhang, Nan
    Zhang, Zhaoqi
    EUROPEAN RADIOLOGY, 2012, 22 (11) : 2432 - 2440
  • [47] Application of prospective ECG-gated multiphase scanning for coronary CT in children with different heart rates
    Shilong Tang
    Guanping Zhang
    Zhuo Chen
    Xianfan Liu
    Ling He
    Japanese Journal of Radiology, 2021, 39 : 946 - 955
  • [48] The role of multidetector-row CT in the diagnosis, classification and management of acute aortic syndrome
    Abbas, A.
    Brown, I. W.
    Peebles, C. R.
    Harden, S. P.
    Shambrook, J. S.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1042)
  • [49] Quantification of aortic valve area with ECG-gated multi-detector spiral computed tomography in patients with aortic stenosis and comparison of two image analysis methods
    Leborgne, Laurent
    Choplin, Yoann
    Renard, Cedric
    Claeys, Mathieu
    Levy, Franck
    Jarry, Genevieve
    Rey, Jean-luc
    Remond, Alexandre
    Quiret, Jean-claude
    Tribouilloy, Christophe
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 135 (02) : 266 - 269
  • [50] Utility of ECG-Gated CTA for Detecting and Classifying Coronary Artery Involvement in Patients With Type A Aortic Dissection and Sinus of Valsalva Involvement
    Ma, Gui-Na
    Hong, Hao
    Alwalid, Osamah
    Cao, Yu-kun
    Hu, Xue-han
    Han, Ping
    Gu, Jin
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (06) : 1334 - 1343