Clinical Validation and Treatment Plan Evaluation Based on Autodelineation of the Clinical Target Volume for Prostate Cancer Radiotherapy

被引:6
|
作者
Shen, Jing [1 ]
Tao, Yinjie [1 ]
Guan, Hui [1 ]
Zhen, Hongnan [1 ]
He, Lei [1 ]
Dong, Tingting [1 ]
Wang, Shaobin [2 ]
Chen, Yu [2 ]
Chen, Qi [2 ]
Liu, Zhikai [1 ,3 ]
Zhang, Fuquan [1 ]
机构
[1] Peking Union Med Coll Hosp, Dept Radiat Oncol, Beijing, Peoples R China
[2] MedMind Technol Co, Radiotherapy Tech Dev Dept, Beijing, Peoples R China
[3] Chinese Acad Med Sci & Peking Union Med Coll, 1 Shuaifuyuan Wangfujing, Beijing 100730, Peoples R China
关键词
prostate cancer radiotherapy; convolutional neural networks; clinical target volume; deep learning; DVH dosimetric index; RADIATION-THERAPY; SEGMENTATION; DELINEATION; ORGANS; RISK; CT;
D O I
10.1177/15330338231164883
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PurposeClinical target volumes (CTVs) and organs at risk (OARs) could be autocontoured to save workload. This study aimed to assess a convolutional neural network for automatic and accurate CTV and OARs in prostate cancer, while comparing possible treatment plans based on autocontouring CTV to clinical treatment plans. MethodsComputer tomography (CT) scans of 217 patients with locally advanced prostate cancer treated at our hospital were retrospectively collected and analyzed from January 2013 to January 2019. A deep learning-based method, CUNet, was used to delineate CTV and OARs. A training set of 195 CT scans and a test set of 28 CT scans were randomly chosen from the dataset. The mean Dice similarity coefficient (DSC), 95th percentile Hausdorff distance (95HD), and subjective evaluation were used to evaluate the performance of this strategy. Predetermined evaluation criteria were used to grade treatment plans, and percentage errors for clinical doses to the planned target volume (PTV) and OARs were calculated. ResultsThe mean DSC and 95HD values of the defined CTVs were (0.84 +/- 0.05) and (5.04 +/- 2.15) mm, respectively. The average delineation time was < 15 s for each patient's CT scan. The overall positive rates for clinicians A and B were 53.15% versus 46.85%, and 54.05% versus 45.95%, respectively (P > .05) when CTV outlines from CUNet were blindly chosen and compared with the ground truth (GT). Furthermore, 8 test patients were randomly chosen to design the predicted plan based on the autocontouring CTVs and OARs, demonstrating acceptable agreement with the clinical plan: average absolute dose differences in mean value of D2, D50, D98, Dmax, and Dmean for PTV were within 0.74%, and average absolute volume differences in mean value of V45 and V50 for OARs were within 3.4%. ConclusionOur results revealed that the CTVs and OARs for prostate cancer defined by CUNet were close to the GT. CUNet could halve the time spent by radiation oncologists in contouring, demonstrating the potential of the novel autocontouring method.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Critical evaluation of the planning target volume for 3-D conformal radiotherapy of prostate cancer
    Tinger, Alfred
    Michalski, Jeff M.
    Cheng, Abel
    Low, Daniel A.
    Zhu, Ron
    Bosch, Walter R.
    Purdy, James A.
    Perez, Carlos A.
    International Journal of Radiation Oncology, Biology, Physics, 42 (01): : 213 - 221
  • [42] Dosimetric evaluation of clinical target volume in the postimplant analysis of low-dose-rate brachytherapy for prostate cancer
    Nasser, Nicola J.
    Sappiatzer, Joshua
    Wang, Yinkun
    Borg, Jette
    Saibishkumar, Elantholi P.
    BRACHYTHERAPY, 2015, 14 (02) : 189 - 196
  • [43] Development and validation of a deep learning algorithm for auto-delineation of clinical target volume and organs at risk in cervical cancer radiotherapy
    Liu, Zhikai
    Liu, Xia
    Guan, Hui
    Zhen, Hongan
    Sun, Yuliang
    Chen, Qi
    Chen, Yu
    Wang, Shaobin
    Qiu, Jie
    RADIOTHERAPY AND ONCOLOGY, 2020, 153 : 172 - 179
  • [44] Development And Validation Of A Deep Learning Algorithm For Auto-Delineation Of Clinical Target Volume And Organs At Risk In Cervical Cancer Radiotherapy
    Zhikai, L.
    Guan, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E766 - E766
  • [45] A new delineation method research of the clinical target volume for pancreatic cancer adjuvant radiotherapy
    Zhang, T. T.
    Wei, L.
    Yuan, G. W.
    Zhao, D. Q.
    Zhang, M. L.
    Zhang, G. F.
    Wang, P. C.
    CANCER RADIOTHERAPIE, 2019, 23 (03): : 201 - 208
  • [46] Clinical target volume in postoperative radiotherapy for gastric cancer: identification of major difficulties and controversies
    Socha, J.
    Wolakiewicz, G.
    Wasilewska-Tesluk, E.
    Janiga, P.
    Kondraciuk, T.
    Majewska, A.
    Olearski, K.
    Kepka, L.
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2016, 18 (05): : 480 - 488
  • [47] Clinical target volume in postoperative radiotherapy for gastric cancer: identification of major difficulties and controversies
    J. Socha
    G. Wołąkiewicz
    E. Wasilewska-Teśluk
    P. Janiga
    T. Kondraciuk
    A. Majewska
    K. Olearski
    L. Kępka
    Clinical and Translational Oncology, 2016, 18 : 480 - 488
  • [48] Clinical target volume (CTV) automatic delineation using deep learning network for cervical cancer radiotherapy: A study with external validation
    Wu, Zhe
    Wang, Dong
    Xu, Cheng
    Peng, Shengxian
    Deng, Lihua
    Liu, Mujun
    Wu, Yi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (01):
  • [49] Type of Breast Cancer Surgery and Postoperative Clinical Target Volume - Implications for Radiotherapy Planning
    Thomson, A. H.
    Palmer, J.
    Brown, I.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S55 - S56
  • [50] USING HISTOPATHOLOGY BREAST CANCER DATA TO REDUCE CLINICAL TARGET VOLUME MARGINS AT RADIOTHERAPY
    Stroom, Joep
    Schlief, Angelique
    Alderliesten, Tanja
    Peterse, Hans
    Bartelink, Harry
    Gilhuijs, Kenneth
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (03): : 898 - 905