A single-ended protection method for flexible DC distribution grid

被引:1
|
作者
Wei, Xiuyan [1 ]
Zou, Guibin [1 ,4 ]
Zhang, Shuo [1 ]
Chen, Chaochao [2 ]
Xu, Chunhua [3 ]
Sun, Weijie [3 ]
机构
[1] Shandong Univ, Minist Educ, Key Lab Power Syst Intelligent Dispatch & Control, Jinan, Peoples R China
[2] State Grid Weifang Power Supply Co, Weifang, Peoples R China
[3] State Grid Weihai Power Supply Co, Weihai, Peoples R China
[4] Shandong Univ, Minist Educ, Key Lab Power Syst Intelligent Dispatch & Control, Jinan 250061, Peoples R China
基金
中国国家自然科学基金;
关键词
current limiting inductance; DC distribution grid; line boundary; single-ended protection; travelling wave; SCHEME;
D O I
10.1049/gtd2.12841
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Considering that no current limiting inductances (CLIs) are installed at the end of the DC line in the flexible DC distribution grid, the protections relying on line boundary are no longer applicable. To overcome this problem, the paper proposes a single-ended protection method independent of line boundary. Firstly, the Peterson equivalent circuit is applied to analyze the amplitude-time ratio of initial voltage travelling wave (ARIVTW) under internal and external faults. Secondly, the fault direction criterion based on the fault component current and the fault type criterion based on the pole voltage are built. Subsequently, the fault identification criterion is constructed by using the ARIVTW, and the corresponding protection method is formed. Finally, the flexible DC distribution grid is built in PSCAD to verify the proposed method. The simulation results show that the method is robust to fault resistance and noise. Besides, the method realizes the protection of the whole line, which has good selectivity and engineering applicability.
引用
收藏
页码:2600 / 2611
页数:12
相关论文
共 50 条
  • [21] Single-ended line protection for MMC-MTDC grids
    Zhang, Shuo
    Zou, Guibin
    Huang, Qiang
    Xu, Bin
    Li, Jun
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (19) : 4331 - 4338
  • [22] A single-ended fault location method for DC lines in bipolar MMC-HVDC system
    Yachao Yang
    Chun Huang
    Electrical Engineering, 2020, 102 : 899 - 908
  • [23] A single-ended fault location method for DC lines in bipolar MMC-HVDC system
    Yang, Yachao
    Huang, Chun
    ELECTRICAL ENGINEERING, 2020, 102 (02) : 899 - 908
  • [24] SINGLE-ENDED CONDUCTANCE
    SHAW, G
    ELECTRONICS & WIRELESS WORLD, 1987, 93 (1612): : 219 - 224
  • [25] A voltage resonance-based single-ended online fault location algorithm for DC distribution networks
    JIA Ke
    LI Meng
    BI Tian Shu
    YANG Qi Xun
    Science China(Technological Sciences), 2016, (05) : 721 - 729
  • [26] A voltage resonance-based single-ended online fault location algorithm for DC distribution networks
    Jia Ke
    Li Meng
    Bi TianShu
    Yang QiXun
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2016, 59 (05) : 721 - 729
  • [27] A SINGLE-ENDED PERFUSION METHOD FOR LARGE, CYLINDRICAL CELLS
    JASLOVE, SW
    JOURNAL OF NEUROSCIENCE METHODS, 1989, 30 (01) : 33 - 40
  • [28] Research on single-ended protection principle of LCC-VSC three-terminal DC transmission line
    Zhang, Dahai
    Wu, Chuanjian
    He, Jinghan
    Luo, Guomin
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 135
  • [29] Pilot Protection Method of Flexible DC Grid Based on Linear Regression
    Shu H.
    Dai Y.
    An N.
    Tang Y.
    Bo Z.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2022, 37 (13): : 3213 - 3288
  • [30] A voltage resonance-based single-ended online fault location algorithm for DC distribution networks
    JIA Ke
    LI Meng
    BI Tian Shu
    YANG Qi Xun
    Science China(Technological Sciences), 2016, 59 (05) : 721 - 729