Comparison of Five Presbyopia-Correcting Intraocular Lenses: Optical-Bench Assessment with Visual-Quality Simulation

被引:15
|
作者
Labuz, Grzegorz [1 ]
Yan, Weijia [1 ]
Baur, Isabella D. D. [1 ]
Khoramnia, Ramin [1 ]
Auffarth, Gerd U. U. [1 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, David J Apple Int Lab Ocular Pathol, D-69120 Heidelberg, Germany
关键词
trifocal intraocular lens; optical quality; modulation-transfer-function; DEPTH-OF-FOCUS; CHROMATIC ABERRATION; IMAGE QUALITY; ACUITY; OUTCOMES; PROFILE; METRICS; DESIGN; MODEL;
D O I
10.3390/jcm12072523
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Presbyopia correction through implantation of a trifocal intraocular lens (IOL) is a modality offered to both cataract and refractive-lens exchange patients. To maximize postoperative satisfaction, IOL selection needs to be made based on patients' requirements aligned with the available technology. Five Trifocal IOLs were assessed in this study, and their differentiating features were identified: Triumf POD L GF, AT Lisa Tri, Tecnis Synergy, AcrySof IQ PanOptix, and Acriva Trinova Pro C. The optical quality was assessed using the modulation-transfer-function principle. Simulated defocus curves were derived from a non-linear formula. Far-focus simulated visual acuity (simVA) was 0.03 logMAR or better for all the studied IOLs, showing minimal differences. However, each IOL's intermediate focus position differed across a range from 61 cm to 80 cm; and for the near focus, it was 36 cm to 44 cm. Triumf demonstrated improved intermediate point at the expense of the near focus resulting in a lower predicted near VA. PanOptix exhibited the shortest range of vision without a clear distinction between intermediate and near-point. The remaining lenses presented three foci of comparable optical quality and, thus, simVA performance. Each model, however, revealed a different aperture-change response. Trinova function improved at intermediate but was worse at near for larger pupils. The opposite was observed for AT Lisa. Synergy's optical quality change was predominantly associated with lower pupil diameter. In conclusion, the trifocal IOLs can be differentiated according to their secondary-foci position, light-energy distribution, and pupil-size-related behavior. The observed differences may translate directly into a clinical effect showing that the trifocal IOLs vary in their ability to deliver optimal vision at different distances, with some providing improved intermediate while others favor reading distance. The knowledge gained through this objective testing can support IOL selection, postoperative patient counselling and increase the chance of spectacle independence after surgery.
引用
收藏
页数:11
相关论文
共 13 条
  • [1] Comparison of Through-Focus Image Sharpness Across Five Presbyopia-Correcting Intraocular Lenses
    Pepose, Jay S.
    Wang, Daozhi
    Altmann, Griffith E.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (01) : 20 - 28
  • [2] Vehicle Headlight Halo Simulation of Presbyopia-Correcting Intraocular Lenses
    Kohnen, Thomas
    Nouri, Sahar A.
    Carson, Daniel
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (12):
  • [3] Comparison of visual results and optical quality of two presbyopia-correcting intraocular lenses: TECNIS symfony versus TECNIS synergy
    Shin, Da Eun
    Lee, Hun
    Kim, Tae-Im
    Koh, Kyungmin
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (06) : 3461 - 3469
  • [4] Comparison of Two Presbyopia-Correcting Trifocal Intraocular Lenses: A Prospective Study
    Bayhan, Hasan Ali
    Tarci, Yelda Yildiz
    Bayhan, Seray Aslan
    Takmaz, Tamer
    Can, Izzet
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2024, 54 (02): : 63 - 68
  • [5] Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench system
    Kim, Myoung Joon
    Zheleznyak, Len
    MacRae, Scott
    Tchah, Hungwon
    Yoon, Geunyoung
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (07) : 1305 - 1312
  • [6] In Vitro Chromatic Performance of Three Presbyopia-Correcting Intraocular Lenses with Different Optical Designs
    Montagud-Martinez, Diego
    Ferrando, Vicente
    Martinez-Espert, Anabel
    Garcia-Delpech, Salvador
    Monsoriu, Juan A.
    Furlan, Walter D.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (05)
  • [7] Impact of corneal aberrations on through-focus image quality of presbyopia-correcting intraocular lenses using an adaptive optics bench system
    Zheleznyak, Len
    Kim, Myoung Joon
    MacRae, Scott
    Yoon, Geunyoung
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (10) : 1724 - 1733
  • [8] Simulation of the Effect of Different Presbyopia-Correcting Intraocular Lenses With Eyes With Previous Laser Refractive Surgery
    Camps, Vicente J.
    Miret, Juan J.
    Garcia, Celia
    Tolosa, Angel
    Pinero, David P.
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (04) : 222 - +
  • [9] Comparison of visual and optical quality of monofocal versus multifocal intraocular lenses
    Altemir-Gomez, Irene
    Millan, Maria S.
    Vega, Fidel
    Bartol-Puyal, Francisco
    Gimenez-Calvo, Galadriel
    Larrosa, Jose M.
    Polo, Vicente
    Pablo, Luis E.
    Garcia-Martin, Elena
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (02) : 299 - 306
  • [10] Geometry of Modern Presbyopia-Correcting Intraocular Lenses and Changes in Haptic-Capsular Bag Behavior According to Compression and Different Well Diameters: A Bench Study Using Computed Tomography
    Borkenstein, Andreas F.
    Borkenstein, Eva-Maria
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (12) : 3059 - 3077