Study on the axial compression behavior of RC columns strengthened with cementitious grout

被引:6
|
作者
Peng, Gang [1 ,2 ]
Hu, Xiaopeng [2 ,3 ]
Niu, Ditao [2 ,3 ]
Zhang, Yong [2 ]
Zhong, Shuai [2 ]
机构
[1] Hunan Univ Sci & Technol, Sch Civil Engn, Xiangtan 411201, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Peoples R China
[3] Xian Univ Architecture & Technol, State Key Lab Green Bldg Western China, Xian 710055, Peoples R China
基金
中国国家自然科学基金;
关键词
Cementitious grout; Replacement position; Replacement thickness; Axial compression capacity; CONCRETE; MODEL;
D O I
10.1016/j.engstruct.2023.115742
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The axial compression behavior of reinforced concrete (RC) columns strengthened with cementitious grout was studied by conducting the axial compressive tests on twelve column specimens. The effects of replacement po-sition and thickness on the failure modes, load-displacement responses, compression capacity, and load-strain curves of the columns were discussed. The results indicated that interfacial cracks were not observed at the interface between the cementitious grout and concrete. The strengthened columns gained peak load enhance-ments of 10.8-61.0%, while the corresponding displacement increased to a lesser extent and even reduced (-16.8-44.9%). Comparisons of axial compression performance of the strengthened specimens with the same replacement ratio but different replacement positions indicated that the strengthening effects of specimens with different replacement positions listed in descending order was: four side replacement, opposite replacement, adjacent replacement, and unilateral replacement. Moreover, the increase of the compression capacity of strengthened columns increased obviously with an increase in the strength of the cementitious grout and replacement ratio, while decreased with an increase in the strength of concrete. The axial strain of the concrete side was larger than that of the cementitious grout side during the loading process for unsymmetrically strengthened columns with cementitious grout, and the specimen exhibited physical eccentricity. Thereafter, an equivalent compression constitutive model of the composite section of RC columns strengthened with cemen-titious grout was proposed based on the established compression constitutive models of concrete and cementi-tious grout. A calculation method for the axial compression capacity of existing RC columns strengthened with cementitious grout was proposed considering the lateral restraint effect of stirrups on concrete and cementitious grout, and reduction of capacity caused by physical eccentricity of specimens. A comparison between the calculated and experimental results demonstrated that the results obtained by the proposed method were in good agreement with that of the experimental results.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Experimental study of axial compression behavior on steel columns strengthened by enclosed reinforced concrete under load
    School of Architecture and Civil Engineering, Shenyang University, Shenyang
    110044, China
    不详
    100084, China
    Jianzhu Jiegou Xuebao, (275-284): : 275 - 284
  • [32] Numerical analysis on axial compression behavior of tenon connection for prefabricated RC columns
    Zhang S.
    Guo Z.
    Liu Y.
    Ye Y.
    Liu X.
    Liu, Yang (lyliuyang@hqu.edu.cn), 1600, Central South University of Technology (51): : 1097 - 1107
  • [33] Axial compressive behavior of predamaged RC columns retrofitted with precast steel-reinforced grout jackets
    Ma, Gao
    Hou, Chunxu
    Cao, Qiongfang
    ENGINEERING STRUCTURES, 2024, 306
  • [34] Experimental study and numerical investigation of behavior of RC beams strengthened with steel reinforced grout
    Bencardino, Francesco
    Condello, Antonio
    COMPUTERS AND CONCRETE, 2014, 14 (06): : 711 - 725
  • [35] Axial performance of RC columns strengthened with different jacketing methods
    Hwang, Yong-Ha
    Yang, Keun-Hyeok
    Mun, Ju-Hyun
    Kwon, Seung-Jun
    ENGINEERING STRUCTURES, 2020, 206
  • [36] Experimental investigation on axial compression behavior of timber columns strengthened with composite reinforcement method
    复合加固木柱轴压特性试验研究
    2021, Chinese Society of Civil Engineering (54): : 1 - 9
  • [37] Axial compression-bending interaction behavior of severely damaged RC columns rapid repaired and strengthened using hybrid FRP composites
    Chellapandian, M.
    Prakash, S. Suriya
    Sharma, Akanshu
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 195 : 390 - 404
  • [38] Study on axial compressive properties of RC square columns strengthened with prestressed CFRP sheets
    Lu, Chun-Ling
    Xiao, Yi-Peng
    Wang, Qiang
    Zhu, Wan-Xu
    STRUCTURES, 2020, 27 : 2011 - 2024
  • [39] Elevated Temperature Response of RC Beams Strengthened with NSM FRP Bars Bonded with Cementitious Grout
    Del Prete, Iolanda
    Bilotta, Antonio
    Bisby, Luke
    Nigro, Emidio
    STRUCTURES IN FIRE, 2016, : 181 - 189
  • [40] Elevated temperature response of RC beams strengthened with NSM FRP bars bonded with cementitious grout
    Del Prete, Iolanda
    Bilotta, Antonio
    Bisby, Luke
    Nigro, Emidio
    COMPOSITE STRUCTURES, 2021, 258