Wearable potentiometric biosensor for analysis of urea in sweat

被引:41
作者
Ibanez-Redin, Gisela [1 ]
Cagnani, Giovana Rosso [2 ]
Gomes, Nathalia O. [2 ]
Raymundo-Pereira, Paulo A. [1 ]
Machado, Sergio A. S. [2 ]
Gutierrez, Marco Antonio [3 ]
Krieger, Jose Eduardo [3 ]
Oliveira, Osvaldo N. [1 ]
机构
[1] Univ Sao Paulo, Sao Carlos Inst Phys, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Sao Paulo, Sao Carlos Inst Chem, BR-13560970 Sao Carlos, SP, Brazil
[3] Univ Sao Paulo, Heart Inst InCor, Med Sch, BR-05403900 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Urea; Electrochemical biosensors; Wearable sensors; Sweat; Roll -to -roll processing; SENSITIVE ELECTROCHEMICAL SENSOR; BLOOD UREA; NANOPARTICLES; ELECTRODE;
D O I
10.1016/j.bios.2022.114994
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Herein, we introduce wearable potentiometric biosensors on screen-printed carbon electrodes (SPCEs) for onbody and on-site monitoring of urea in sweat. The biosensor architecture was judiciously designed to detect urea at different pHs and incorporate a pH sensor, thus containing polyaniline ink, urease bioink and a polyvinylchloride membrane. Urea detection could be performed in the wide range from 5 to 200 mM at pH 7.0, encompassing urea levels in human sweat. The biosensor response was fast (incubation time 5 min), with no interference from other substances in sweat. Reliable urea detection could be done in undiluted human sweat with a skin-worn flexible device using the pH correction strategy afforded by the pH sensor. The performance of the epidermal biosensor was not affected by severe bending strains. The feasibility of mass production was demonstrated by fabricating epidermal flexible biosensors using slot-die coating with a roll-to-roll technique.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A non-invasive wearable sweat biosensor with a flexible N-GQDs/PANI nanocomposite layer for glucose monitoring
    Lin, Yu-Chi
    Rinawati, Mia
    Chang, Ling-Yu
    Wang, Yu-Xuan
    Wu, Yu-Ting
    Yen, Yi-Han
    Chen, Kuan-Jung
    Ho, Kuo-Chuan
    Yeh, Min-Hsin
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 383
  • [32] Carbon Nitride Quantum Dots/Polyaniline Nanocomposites for Non-Invasive Glucose Monitoring Using Wearable Sweat Biosensor
    Chiu, Yi-Hao
    Rinawati, Mia
    Chang, Ling-Yu
    Guo, Yi-Ting
    Chen, Kuan-Jung
    Chiu, Hsiang-Chih
    Lin, Zong-Hong
    Huang, Wei-Hsiang
    Haw, Shu-Chih
    Yeh, Min-Hsin
    ACS APPLIED NANO MATERIALS, 2025, 8 (05) : 2340 - 2351
  • [34] Application of potentiometric biosensor based on recombinant urease for urea determination in blood serum and hemodialyzate
    Marchenko, S. V.
    Kucherenko, I. S.
    Hereshko, A. N.
    Panasiuk, I. V.
    Soldatkin, O. O.
    El'skaya, A. V.
    Soldatkin, A. P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 981 - 986
  • [35] Uric acid and urea in human sweat
    Huang, CT
    Chen, ML
    Huang, LL
    Mao, IF
    CHINESE JOURNAL OF PHYSIOLOGY, 2002, 45 (03): : 109 - 115
  • [36] Potentiometric urea biosensor utilizing nanobiocomposite of chitosan-iron oxide magnetic nanoparticles
    Ali, A.
    AlSalhi, M. S.
    Atif, M.
    Ansari, Anees A.
    Israr, M. Q.
    Sadaf, J. R.
    Ahmed, E.
    Nur, O.
    Willander, M.
    21ST INTERNATIONAL LASER PHYSICS WORKSHOP, 2013, 414
  • [37] Urea transporters and sweat response to uremia
    Keller, Raymond W.
    Bailey, James L.
    Wang, Yanhua
    Klein, Janet D.
    Sands, Jeff M.
    PHYSIOLOGICAL REPORTS, 2016, 4 (11):
  • [38] The Analysis of Potentiometric Flexible Arrayed Urea Biosensor Modified by Graphene Oxide and γ-Fe2O3 Nanoparticles
    Nien, Yu-Hsun
    Su, Tzu-Yu
    Ho, Chih-Sung
    Chou, Jung-Chuan
    Lai, Chih-Hsien
    Kuo, Po-Yu
    Kang, Zhi-Xuan
    Dong, Zhe-Xin
    Lai, Tsu-Yang
    Wang, Chu-Hsuan
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2020, 67 (11) : 5104 - 5110
  • [39] Wearable cellulose textile matrix self-powered biosensor sensing lactate in human sweat
    Xia, Zunbin
    Zuo, Wei
    Li, Haiying
    Qiu, Liewei
    Mu, Ruihua
    Wang, Qian
    Liu, Hongchen
    Wang, Huixin
    Hui, Yuchen
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (05) : 1137 - 1152
  • [40] Wearable cellulose textile matrix self-powered biosensor sensing lactate in human sweat
    Zunbin Xia
    Wei Zuo
    Haiying Li
    Liewei Qiu
    Ruihua Mu
    Qian Wang
    Hongchen Liu
    Huixin Wang
    Yuchen Hui
    Journal of Applied Electrochemistry, 2024, 54 : 1137 - 1152