Transient flow analysis on opening process of pneumatic gas proportional valve with two-solenoid valve

被引:7
|
作者
Liu, Fengguo [1 ,2 ]
Cao, Shihua [1 ]
Zhou, Wenlei [1 ]
Zhao, Dongfang [1 ]
Zheng, Longfeng [1 ]
Shao, Meng [1 ]
机构
[1] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
[2] Tianjin Engn Ctr Nat Gas High Efficiency Utilizat, Tianjin 300384, Peoples R China
关键词
Gas proportional valve; Spool opening; Flow; Outlet flow rate; CFD; CFD ANALYSIS; SIMULATION; DYNAMICS; FORCES; SPOOL; MODEL;
D O I
10.1016/j.flowmeasinst.2022.102291
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The gas proportional valve (GPV) is a pneumatic pressure regulator, and the change in operating pressure will directly affect the opening and closing condition of the spool. In this study, the procedure for opening the spool is studied. The process of regulating the pressure of the GPV is revealed by the dynamical simulation method. The characteristics of displacement, total pressure and velocity of the spool during opening are analyzed. As time increases, it is found that the turbulence in the downstream of GPV becomes more obvious. In the process of spool movement, the influence of different inlet working pressures on spool displacement is analyzed. With a full open time of less than 1.5 x 10(boolean AND) (-2) s, the spool reaches the stable state of full opening. In addition, the transient process of outlet flow is also studied. The simulated outlet flow is stable at 152 m(3)/h for the maximum opening. In order to verify the simulation results, the test of valve flow is carried out on the test bench. The results show that these methods can reduce the design difficulty and provide a reference for further optimization and engineering application of GPV.
引用
收藏
页数:13
相关论文
共 33 条
  • [21] Numerical Analysis and Optimisation of the Flow Forces in a Water Hydraulic Proportional Cartridge Valve for Injection System
    Han, Mingxing
    Liu, Yinshui
    Wu, Defa
    Tan, Huaijiang
    Li, Chao
    IEEE ACCESS, 2018, 6 : 10392 - 10401
  • [22] Numerical study on the flow characteristics of ultrahigh pressure gas affected by valve opening time based a real gas model
    Zhang, Haitao
    Sun, Shuo
    Kang, Yong
    Fan, Chenxing
    Zhang, Zenglei
    Li, Deng
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2024, 46 (03)
  • [23] Three dimensional CFD analysis and experimental test of flow force acting on the spool of solenoid operated directional control valve
    Lisowski, E.
    Czyzycki, W.
    Rajda, J.
    ENERGY CONVERSION AND MANAGEMENT, 2013, 70 : 220 - 229
  • [24] Analysis of flow torques during opening and closing of high-frequency rotary directional control valve
    Jia, Wenang
    Ni, Zifan
    Li, Zhanshang
    Li, Sheng
    FLOW MEASUREMENT AND INSTRUMENTATION, 2023, 89
  • [25] Three-dimensional study of the effect of two leaflet opening angles on the time-dependent flow through a bileaflet mechanical heart valve
    King, MJ
    David, T
    Fisher, J
    MEDICAL ENGINEERING & PHYSICS, 1997, 19 (03) : 235 - 241
  • [26] The importance of a full 3D fluid dynamic analysis to evaluate the flow forces in a hydraulic directional proportional valve
    Amirante, Riccardo
    Catalano, Luciano Andrea
    Tamburrano, Paolo
    ENGINEERING COMPUTATIONS, 2014, 31 (05) : 898 - 922
  • [27] Experimental study on the two-phase flow of gas-particles through a model brake valve
    Zhang, Guang
    Zhang, Yi Fan
    Liu, Qi
    Li, Yi
    Lin, Zhe
    POWDER TECHNOLOGY, 2020, 367 (367) : 172 - 182
  • [28] Experimental and numerical study on gas-solid two-phase flow through regulating valve of pulverized coal flow
    Chen, Meihua
    Lu, Haifeng
    Jin, Yong
    Guo, Xiaolei
    Gong, Xin
    Liu, Haifeng
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2020, 155 : 1 - 11
  • [29] Analysis of an extremely fast valve opening camless system to improve transient performance in a turbocharged high speed direct injection diesel engine
    Benajes, J.
    Serrano, J. R.
    Dolz, V.
    Novella, R.
    INTERNATIONAL JOURNAL OF VEHICLE DESIGN, 2009, 49 (1-3) : 192 - 213
  • [30] Fluid dynamic analysis of liquefied natural gas flow through a cryogenic ball valve in liquefied natural gas receiving stations
    Lin, Zhen-hao
    Li, Jun-ye
    Jin, Zhi-jiang
    Qian, Jin-yuan
    ENERGY, 2021, 226