Impact of Prophylactic Fluoride Agents On the Surface Roughness of Newer orthodontic arch wires

被引:0
作者
Panda, Suchareeta [1 ]
Anandu, M. [2 ]
Goutham, N. [3 ]
Bai, M. Pavithra [4 ]
Pani, Saibalini [1 ]
Rao, Sakesth Rama [5 ]
机构
[1] Siksha O Anusandhan Univ, Deemed Univ, Inst Dent Sci, Dept Orthodont, Bhubaneswar, Odisha, India
[2] PES Univ Med Sci, Deemed Univ, Dept Dent, Bangalore, Karnataka, India
[3] Rajiv Gandhi Univ Hlth Sci, VS Dent Coll & Hosp, Dept Orthodont, Bangalore, Karnataka, India
[4] Utkal Univ, Hitech Dent Coll & Hosp, Dept Orthodont, Bhubaneswar, Odisha, India
[5] Hitech Dent Coll & Hosp, Dept Conservat Dent, Bhubaneswar, Odisha, India
来源
BANGLADESH JOURNAL OF MEDICAL SCIENCE | 2024年 / 23卷
关键词
Surface topography; Surface roughness; Fluorides; Ni-Ti wires; Braided Ni-Ti wires; Coated Ni-Ti wires; Phosflur gel; Prevident; 5000; MECHANICAL-PROPERTIES; NICKEL-TITANIUM;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fluorides serve an important part in orthodontic therapy as a prophylactic strategy. However, the harmful effects of fluoride are typically disregarded due to its widespread use as an anticariogenic agent in a variety of dental materials. The effects of these fluoride agents on conventional arch wires have been studied extensively but not on newer wires such as coated wires or braided wires. Hence this study was undertaken to assess the effects of prophylactic fluoride agents on the surface properties of non -coated Nickel -Titanium orthodontic wires and compare it with coated esthetic Ni-Ti wires and braided Ni-Ti wire.Materials and methods: In this study, we compared three packages of 270 orthodontic arch wires made of nickel titanium. For the control, the third set of 30 wires was stored in plastic vials containing 5ml of artificial saliva for two months. Subgroup a did not make use of any fluoride treatments. Samples from subgroup b were treated with Phos-flur gel for one minute every day for 2 months, while those from subgroup c were treated with Prevident 5000. An optic profilometer was used to measure the wires roughness. Results: The investigation found that both the acidulated fluoride agent (Phos-flur gel) and neutral fluoride agent (Prevident 5000) had an effect on the surface attributes of all three sets of wires. Coated esthetic Ni-Ti wires showed highest surface roughness followed by braided Ni-Ti wire. Conclusion: The findings of the research showed that using fluoride preventive treatments (such as mouthwash or gels) during orthodontic treatment decreases the arch wires characteristics.
引用
收藏
页码:S107 / S114
页数:8
相关论文
共 12 条
  • [1] Abdulqader MH, 2022, J RES MED DENT SCI, V10, P662
  • [2] Coating stability and surface characteristics of esthetic orthodontic coated archwires
    da Silva, Dayanne Lopes
    Mattos, Claudia Trindade
    Simao, Renata Autoun
    de Oliveira Ruellas, Antonio Carlos
    [J]. ANGLE ORTHODONTIST, 2013, 83 (06) : 994 - 1001
  • [3] Mechanical properties and surface characterization of translucent composite wire following topical fluoride treatment
    Hammad, Shaza M.
    Al-Wakeel, Essam E.
    Gad, El-Sayed
    [J]. ANGLE ORTHODONTIST, 2012, 82 (01) : 8 - 13
  • [4] Kaneko K, 2004, ANGLE ORTHOD, V74, P487
  • [5] Delayed fracture of beta titanium orthodontic wire in fluoride aqueous solutions
    Kaneko, K
    Yokoyama, K
    Moriyama, K
    Asaoka, K
    Sakai, J
    Nagumo, M
    [J]. BIOMATERIALS, 2003, 24 (12) : 2113 - 2120
  • [6] Kim H, 1999, ANGLE ORTHOD, V69, P39
  • [7] Evaluation of the effect of fluoride-containing acetic acid on NiTi wires
    Kwon, YH
    Cho, HS
    Noh, DJ
    Kim, HI
    Kim, KH
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (01) : 102 - 108
  • [8] Utilization of residual space of deciduous second molar to align teeth in a crowded arch
    Nessa, Kamrun
    Anwar, Nabila
    Ghosh, Ranjit
    Mondal, Sonali
    Alam, Mohammad Khursheed
    [J]. BANGLADESH JOURNAL OF MEDICAL SCIENCE, 2020, 19 (04): : 763 - 768
  • [9] In Vitro Effect Of Fluoride Prophylactic Agents On Titanium Molybdenum Alloy And Stainless Steel Orthodontic Wires-Scanning Electron Microscope Study
    Sahoo, Nivedita
    Bhuyan, Lipsa
    Dhull, Kanika Singh
    Dash, Kailash Chandra
    Indira, Indira
    Mishra, Dr. Pallavi
    [J]. BANGLADESH JOURNAL OF MEDICAL SCIENCE, 2023, 22 : S47 - S51
  • [10] Effect of fluoride prophylactic agents on the mechanical properties of nickel-titanium-based orthodontic wires
    Walker, MP
    White, RJ
    Kula, KS
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 127 (06) : 662 - 669