Comparison of Ultrasound-Guided Versus Palpatory Method of Posterior Tibial Artery Cannulation: A Prospective Randomized Controlled Study

被引:2
|
作者
Eda, Jhansi [1 ]
Gupta, Priyanka [2 ]
Kaushal, Ashutosh [3 ]
机构
[1] All India Inst Med Sci, Anaesthesiol, Rishikesh, India
[2] All India Inst Med Sci, Anesthesiol & Crit Care, Rishikesh, India
[3] All India Inst Med Sci, Anesthesiol, Bhopal, India
关键词
cannulation attempts; first attempt success rate; arterial cannulation; palpatory technique; ultrasound; posterior tibial artery; RADIAL ARTERY; ADULT PATIENTS; CATHETERIZATION; METAANALYSIS; GUIDANCE; TRIAL;
D O I
10.7759/cureus.51087
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Superficial arteries, such as radial and dorsalis pedis arteries, are commonly cannulated for invasive blood pressure monitoring. Failure to cannulate these arteries necessitates alternate arteries, such as the posterior tibial artery (PTA). The deep-seated anatomy of PTA makes arterial cannulation precarious by the palpatory technique. Ultrasound guidance during PTA cannulation may overcome this problem. With this background, we evaluated the ultrasound -guided (USG) versus palpatory method for PTA cannulation with respect to the first attempt's success and number of attempts. Methods: A total of 240 American Society of Anesthesiology (ASA) physical status I -IV adult patients undergoing major surgeries requiring arterial cannulation were randomly allocated (1:1) to group A (USGguided cannulation, n = 120) and Group B (cannulation by palpatory technique, n =120). PTA was cannulated by either of the techniques according to randomization. Data were analyzed and compared in both groups for first -attempt success, number of attempts, assessment time, cannulation time, and complications. Result: The successful cannulation in the first attempt in Group A was 25.8% (n = 31), and in Group B, it was 12.5% (n = 15) (p = 0.009). In Group A, 78.3% of patients (n = 94) had successful cannulation, and in group B, 65% of patients (n =78) had successful cannulation (p = 0.022). Both groups had similar assessment time (p = 0.348) and cannulation time (p = 0.864). Conclusion: USG -guided PTA cannulation offers a greater chance of success without any added increase in procedure time.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparison between marked versus unmarked introducer needle in real-time ultrasound-guided central vein cannulation: A prospective randomized study
    Ghatak, Tanmoy
    Singh, Ratender Kumar
    Baronia, Arvind Kumar
    ANNALS OF CARDIAC ANAESTHESIA, 2016, 19 (04) : 621 - 625
  • [22] Comparison of ultrasound-guided internal jugular vein cannulation versus supraclavicular approach to brachiocephalic vein cannulation- A prospective, single-blind, randomised study
    Gowda, Keerthi
    Desai, Sameer
    INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 (08) : 553 - 558
  • [23] Comparison of an ultrasound-guided technique versus a landmark-guided technique for internal jugular vein cannulation
    Dolu, Hasan
    Goksu, Sitki
    Sahin, Levent
    Ozen, Onder
    Eken, Levent
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (01) : 177 - 182
  • [24] Ultrasound-guided radial artery catheterization at different sites: a prospective and randomized study
    Wu, X-L
    Wang, J-J
    Yuan, D-Q
    Chen, W-T
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2022, 26 (02) : 415 - 421
  • [25] Modified long-axis in-plane ultrasound-guided radial artery cannulation in adult patients: A randomized controlled trial
    Wang, Jiebo
    Weng, Xianfeng
    Huang, Qijian
    Lai, Zhongmeng
    Zhao, Zisong
    Lan, Jianning
    Wu, Guohua
    Lin, Lei
    Su, Jiansheng
    Liu, Junle
    Zhang, Liangcheng
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2022, 41 (01)
  • [26] Comparison of Mill Suss™-guided radial artery catheterization with the long-axis in-plane ultrasound-guided method under general anesthesia: a randomized controlled trial
    Osuda, Michiko
    Edanaga, Mitsutaka
    Matsumoto, Tomomi
    Yamamoto, Asuka
    Ihara, Saki
    Tanaka, Satoru
    Yamakage, Michiaki
    JOURNAL OF ANESTHESIA, 2020, 34 (03) : 464 - 467
  • [27] Comparison of Mill Suss™-guided radial artery catheterization with the long-axis in-plane ultrasound-guided method under general anesthesia: a randomized controlled trial
    Michiko Osuda
    Mitsutaka Edanaga
    Tomomi Matsumoto
    Asuka Yamamoto
    Saki Ihara
    Satoru Tanaka
    Michiaki Yamakage
    Journal of Anesthesia, 2020, 34 : 464 - 467
  • [28] The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial
    Oh, Ah-Young
    Jeon, Young-Tae
    Choi, Eun-Joo
    Ryu, Jung-Hee
    Hwang, Jung-Won
    Park, Hee-Pyoung
    Do, Sang-Hwan
    BMC ANESTHESIOLOGY, 2014, 14
  • [29] A novel method for ultrasound-guided radial artery cannulation in neonates by trainee anaesthesiologists A randomised controlled trial
    Ye, Ping
    Tan, Yanzhe
    Ye, Mao
    Li, Shangyingying
    Bai, Lin
    Liu, Lifei
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (02) : 91 - 97
  • [30] Comparison of procedural time with two different ultrasound-guided approaches for dorsalis pedis artery cannulation in adult patients: A randomized trial
    Karan, Priyabrat
    Sharma, Ankur
    Mukesh, Arun
    Goyal, Shilpa
    Rathod, Darshna
    Kumari, Kamlesh
    Meshram, Tanvi
    Kothari, Nikhil
    Bhatia, Pradeep