Gaussian Processes for real-time 3D motion and uncertainty estimation during MR-guided radiotherapy

被引:11
作者
Huttinga, Niek R. F. [1 ]
Bruijnen, Tom
van den Berg, Cornelis A. T.
Sbrizzi, Alessandro
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, Div Imaging & Oncol, Utrecht, Netherlands
基金
荷兰研究理事会;
关键词
Respiratory motion; MR-guided radiotherapy; MR-linac; Real-time; Motion estimation; Uncertainty estimation; Gaussian Processes; RESPIRATORY MOTION; IMAGE-RECONSTRUCTION; MODEL; RADIATION;
D O I
10.1016/j.media.2023.102843
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Respiratory motion during radiotherapy causes uncertainty in the tumor's location, which is typically addressed by an increased radiation area and a decreased dose. As a result, the treatments' efficacy is reduced. The recently proposed hybrid MR-linac scanner holds the promise to efficiently deal with such respiratory motion through real-time adaptive MR-guided radiotherapy (MRgRT). For MRgRT, motion-fields should be estimated from MR-data and the radiotherapy plan should be adapted in real-time according to the estimated motion -fields. All of this should be performed with a total latency of maximally 200 ms, including data acquisition and reconstruction. A measure of confidence in such estimated motion-fields is highly desirable, for instance to ensure the patient's safety in case of unexpected and undesirable motion. In this work, we propose a framework based on Gaussian Processes to infer 3D motion-fields and uncertainty maps in real-time from only three readouts of MR-data. We demonstrated an inference frame rate up to 69 Hz including data acquisition and reconstruction, thereby exploiting the limited amount of required MR-data. Additionally, we designed a rejection criterion based on the motion-field uncertainty maps to demonstrate the framework's potential for quality assurance. The framework was validated in silico and in vivo on healthy volunteer data (n = 5) acquired using an MR-linac, thereby taking into account different breathing patterns and controlled bulk motion. Results indicate end-point-errors with a 75th percentile below 1 mm in silico, and a correct detection of erroneous motion estimates with the rejection criterion. Altogether, the results show the potential of the framework for application in real-time MR-guided radiotherapy with an MR-linac.
引用
收藏
页数:14
相关论文
共 46 条
[1]   Adaptive retrospective correction of motion artifacts in cranial MRI with multicoil three-dimensional radial acquisitions [J].
Anderson, Ashley G., III ;
Velikina, Julia ;
Block, Walter ;
Wieben, Oliver ;
Samsonov, Alexey .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) :1094-1103
[2]   Thermal noise variance of a receive radiofrequency coil as a respiratory motion sensor [J].
Andreychenko, A. ;
Raaijmakers, A. J. E. ;
Sbrizzi, A. ;
Crijns, S. P. M. ;
Lagendijk, J. J. W. ;
Luijten, P. R. ;
van den Berg, C. A. T. .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) :221-228
[3]   A PARALLEL NONUNIFORM FAST FOURIER TRANSFORM LIBRARY BASED ON AN "EXPONENTIAL OF SEMICIRCLE" KERNEL [J].
Barnett, Alexander H. ;
Magland, Jeremy ;
Klinteberg, Ludvig A. F. .
SIAM JOURNAL ON SCIENTIFIC COMPUTING, 2019, 41 (05) :C479-C504
[4]   Autoadaptive motion modelling for MR-based respiratory motion estimation [J].
Baumgartner, Christian F. ;
Kolbitsch, Christoph ;
McClelland, Jamie R. ;
Rueckert, Daniel ;
King, Andrew P. .
MEDICAL IMAGE ANALYSIS, 2017, 35 :83-100
[5]  
Bengio Y., 2006, Advances in neural information processing systems, P107
[6]   Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes [J].
Bjerre, Troels ;
Crijns, Sjoerd ;
af Rosenschold, Per Munck ;
Aznar, Marianne ;
Specht, Lena ;
Larsen, Rasmus ;
Keall, Paul .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (14) :4943-4950
[7]  
Bonilla Edwin V., 2007, Advances in Neural Information Processing Systems, V20
[8]   3D Delivered Dose Assessment Using a 4DCT-Based Motion Model [J].
Cai, W. ;
Hurwitz, M. ;
Williams, C. ;
Dhou, S. ;
Berbeco, R. ;
Seco, J. ;
Cifter, F. ;
Myronakis, M. ;
Mishra, P. ;
Lewis, J. .
MEDICAL PHYSICS, 2015, 42 (06) :3669-3669
[9]   Temporal Stability of Adaptive 3D Radial MRI Using Multidimensional Golden Means [J].
Chan, Rachel W. ;
Ramsay, Elizabeth A. ;
Cunningham, Charles H. ;
Plewes, Donald B. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) :354-363
[10]   Noninvasive Cardiac Radiation for Ablation of Ventricular Tachycardia [J].
Cuculich, Phillip S. ;
Schill, Matthew R. ;
Kashani, Rojano ;
Mutic, Sasa ;
Lang, Adam ;
Cooper, Daniel ;
Faddis, Mitchell ;
Gleva, Marye ;
Noheria, Amit ;
Smith, Timothy W. ;
Hallahan, Dennis ;
Rudy, Yoram ;
Robinson, Clifford G. .
NEW ENGLAND JOURNAL OF MEDICINE, 2017, 377 (24) :2325-2336