Accurate determination of rare earth elements in small volumes of porewater from marine sediments by laser ablation solution sampling ICP-MS

被引:4
作者
Liao, Xiuhong [1 ]
Zhang, Wen [1 ]
Yang, Tao [2 ]
Hu, Zhaochu [1 ]
Luo, Tao [1 ]
Zeng, Xianli [1 ]
Zhou, Lian [1 ]
机构
[1] China Univ Geosci, State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China
[2] Nanjing Univ, Sch Earth Sci & Engn, State Key Lab Mineral Deposits Res, Nanjing 210023, Peoples R China
基金
中国国家自然科学基金;
关键词
PLASMA-MASS SPECTROMETRY; PRECONCENTRATION/MATRIX REDUCTION METHOD; PORE WATERS; GEOLOGICAL SAMPLES; ISOTOPE-DILUTION; SEAWATER; GEOCHEMISTRY; SEPARATION; HYDROXIDE; CHEMISTRY;
D O I
10.1039/d2ja00236a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rare earth elements (REEs) in porewater can be useful proxies in the studies of marine geochemistry. The main challenges for the determination of REEs in porewater samples from marine sediments lie in three aspects-low concentration, high salinity, and limited sample sizes (usually only a few millilitres). In this study, a method based on laser ablation (LA) solution sampling ICP-MS for REEs analysis of small volumes (2-4 mL) of porewater is established. With the help of matrix removal and REEs preconcentration from natural liquids by a miniaturized Fe(OH)(3) co-precipitation method, a high enrichment factor (10-20 fold) was achieved with only 2 mL of the original liquid, which was preconcentrated to be as small as 100-200 mu L. Ultratrace (sub-pg mL(-1)) analysis was realized through the use of high laser ablation pulse frequency (up to 250 Hz) and based on the high transport efficiency of aerosol particles by the LA system. Due to the almost "dry" ICP condition generated by LA and nitrogen addition (5 mL min(-1)) to the plasma, the CeO+/Ce+ ratio was reduced to approximately 0.05%, and the total yields of BaO+ and BaOH+ ions were reduced to 0.003%, which means that the potential biases induced by oxide and hydroxide interferences could be negligible. Method validation was achieved through the analysis of the seawater reference material NASS-7 and a spike recovery test with quantitative recoveries of 94-101% for REEs. The application results of porewater samples characterized by no or slight Ce anomalies together with significantly positive Eu anomalies may be indicative of highly reducing and neutral to basic pH conditions. Reagents consumed by the LA-ICP-MS method were significantly reduced, making it a more environment-friendly method. Moreover, the simplicity in sample preparation and lack of need for special reagents or devices give the proposed method great potential for wide applications in the determination of REEs in natural water samples.
引用
收藏
页码:156 / 165
页数:10
相关论文
共 51 条
  • [41] The influence of volcanic ash alteration on the REE composition of marine pore waters
    Schacht, Ulrike
    Wallmann, Klaus
    Kutterolf, Steffen
    [J]. JOURNAL OF GEOCHEMICAL EXPLORATION, 2010, 106 (1-3) : 176 - 187
  • [42] A preconcentration/matrix reduction method for the analysis of rare earth elements in seawater and groundwaters by isotope dilution ICPMS
    Shaw, TJ
    Duncan, T
    Schnetger, B
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (14) : 3396 - 3403
  • [43] THE PORE WATER CHEMISTRY OF RARE-EARTH ELEMENTS IN BUZZARDS BAY SEDIMENTS
    SHOLKOVITZ, ER
    PIEPGRAS, DJ
    JACOBSEN, SB
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 1989, 53 (11) : 2847 - 2856
  • [44] THE GEOCHEMISTRY OF RARE-EARTH ELEMENTS IN THE SEASONALLY ANOXIC WATER COLUMN AND POREWATERS OF CHESAPEAKE BAY
    SHOLKOVITZ, ER
    SHAW, TJ
    SCHNEIDER, DL
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 1992, 56 (09) : 3389 - 3402
  • [45] Rare earth element cycling in the pore waters of the Bering Sea Slope (IODP Exp. 323)
    Soyol-Erdene, Tseren-Ochir
    Huh, Youngsook
    [J]. CHEMICAL GEOLOGY, 2013, 358 : 75 - 89
  • [46] ADDITION OF MOLECULAR GASES TO ARGON GAS-FLOWS FOR THE REDUCTION OF POLYATOMIC-ION INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    WANG, JS
    EVANS, EH
    CARUSO, JA
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) : 929 - 936
  • [47] Flow injection on-line group preconcentration and separation of (ultra)trace rare earth elements in environmental and geological samples by precipitation using a knotted reactor as a filterless collector for inductively coupled plasma mass spectrometric determination
    Yan, XP
    Kerrich, R
    Hendry, MJ
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (02) : 215 - 221
  • [48] Inter-laboratory study for the certification of trace elements in seawater certified reference materials NASS-7 and CASS-6
    Yang, Lu
    Nadeau, Kenny
    Meija, Juris
    Grinberg, Patricia
    Pagliano, Enea
    Ardini, Francisco
    Grotti, Marco
    Schlosser, Christian
    Streu, Peter
    Achterberg, Eric P.
    Sohrin, Yoshiki
    Minami, Tomoharu
    Zheng, Linjie
    Wu, Jingfeng
    Chen, Gedun
    Ellwood, Michael J.
    Turetta, Clara
    Aguilar-Islas, Ana
    Rember, Robert
    Sarthou, Geraldine
    Tonnard, Manon
    Planquette, Helene
    Matousek, Tomas
    Crum, Steven
    Mester, Zoltan
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (18) : 4469 - 4479
  • [49] A seawater-based open and continuous process for polyhydroxyalkanoates production by recombinant Halomonas campaniensis LS21 grown in mixed substrates
    Yue, Haitao
    Ling, Chen
    Yang, Tao
    Chen, Xiangbin
    Chen, Yuling
    Deng, Haiteng
    Wu, Qiong
    Chen, Jinchun
    Chen, Guo-Qiang
    [J]. BIOTECHNOLOGY FOR BIOFUELS, 2014, 7
  • [50] Determination of rare earth elements by spectroscopic techniques: a review
    Zawisza, Beata
    Pytlakowska, Katarzyna
    Feist, Barbara
    Polowniak, Marzena
    Kita, Andrzej
    Sitko, Rafal
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (12) : 2373 - 2390