The impact of soil layering and groundwater flow on energy pile thermal performance

被引:9
|
作者
Alqawasmeh, Qusi I. [1 ]
Narsilio, Guillermo A. [1 ]
Makasis, Nikolas [1 ,2 ,3 ]
Kreitmair, Monika J. [2 ,3 ]
机构
[1] Univ Melbourne, Dept Infrastruct Engn, Engn Block B 205, Parkville, Vic 3010, Australia
[2] Univ Surrey, Sch Sustainabil Civil & Environm Engn, Guildford GU2 7XH, Surrey, England
[3] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
关键词
Shallow geothermal energy; Ground layering; Groundwater flow; Energy piles; Thermal conductivity; BOREHOLE HEAT-EXCHANGER; GEOTHERMAL-ENERGY; ANALYTICAL-MODEL; PUMP SYSTEMS; BEHAVIOR; DESIGN; SUBSURFACE; PARAMETERS;
D O I
10.1016/j.gete.2024.100538
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Shallow geothermal energy pile systems have emerged as cost-effective and low-carbon alternatives for heating and cooling buildings, compared to traditional air-conditioning systems. Geothermal applications have been researched extensively in recent years under the assumption of ground homogeneity, and the effect of ground stratification remains mostly unexplored. To investigate this, a 3D finite element numerical model is developed and validated against laboratory-scale experimental data, to study the transient diffusion-convection heat transfer linked with Darcy groundwater flow around energy piles in multi-layered lithology. The model is used to undertake long-term assessments under balanced and unbalanced thermal loads to evaluate the thermal effects of soil layering and discrepancies against commonly assumed equivalent homogeneous stratum, for soil profiles with different thermal conductivity distributions. The groundwater flow effect at various depths and seepage velocities on the thermal performance of the energy pile is investigated as well. Results demonstrate the need to account for the spatial variability in thermal properties, particularly for unbalanced thermal loading scenarios. The thermal yield can be underestimated by up to 19.6 % due to an inaccuracy of 48.2 % in the accumulated temperature after 25-year of operation with respect to an equivalent homogeneous ground with depth-weighted average thermal conductivity. This discrepancy grows as the contrast between layers increases. An empirical derived formula is presented and tested, presenting a correction to the effective thermal conductivity of the layered systems in this study that considers the thermal contribution of the ground beneath the pile. Groundwater seepage is shown to have a positive impact on the heat exchanger efficiency, and in the layered geology the efficiency under-estimation becomes more critical at low to moderate Darcy velocities, if neglected or inaccurately measured. These findings contribute to a broader understanding of energy piles and can assist engineers and practitioners in optimising energy geo-structure design, boosting the technology's viability.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Numerical Analysis of the Soil Thermal Response Close to a Partially Submerged Geothermal Energy Pile in the Groundwater Flow
    Jazi, Fereydoun Najafian
    Mohammadzadeh, Amin
    Ghasemi-Fare, Omid
    Rockaway, Thomas D.
    IFCEE 2024: DRILLED AND DRIVEN FOUNDATIONS AND INNOVATIVE AND EMERGING APPROACHES FOR FOUNDATION ENGINEERING, 2024, 354 : 94 - 104
  • [2] Numerical research on thermal response for geothermal energy pile groups under groundwater flow
    Lou, Yang
    Fang, Peng-fei
    Xie, Xin-yu
    Chong, Chiew Shan Anthony
    Li, Fu-yuan
    Liu, Chun-yang
    Wang, Zhong-jin
    Zhu, Da-yong
    GEOMECHANICS FOR ENERGY AND THE ENVIRONMENT, 2021, 28
  • [3] Investigating the thermal performance of energy soldier pile walls
    Makasis, Nikolas
    Narsilio, Guillermo A.
    GEOMECHANICS FOR ENERGY AND THE ENVIRONMENT, 2022, 30
  • [4] The role of ground hydrothermal spatial variability on energy pile group thermal performance
    Alqawasmeh, Qusi I.
    Kreitmair, Monika J.
    Narsilio, Guillermo A.
    COMPUTERS AND GEOTECHNICS, 2025, 179
  • [5] Experimental investigation on the impact of the asymmetrical heat exchange and operation modes on the thermal performance of a bored energy pile in unsaturated soil: A case study in Brazil
    Formigari, Ricardo Caires
    Tsuha, Cristina de Hollanda Cavalcanti
    GEOTHERMICS, 2025, 125
  • [6] Experimental study on the thermal performance of tunnel lining GHE under groundwater flow
    Zhang, Guozhu
    Guo, Yimu
    Zhou, You
    Ye, Meixi
    Chen, Runfa
    Zhang, Hualin
    Yang, Junda
    Chen, Jiawei
    Zhang, Menghuan
    Lian, Yanjian
    Liu, Chenyang
    APPLIED THERMAL ENGINEERING, 2016, 106 : 784 - 795
  • [7] Analysis of thermo-active pile structures and their performance under groundwater flow conditions
    Gashti, E. Hassani Nezhad
    Malaska, M.
    Kujala, K.
    ENERGY AND BUILDINGS, 2015, 105 : 1 - 8
  • [8] Centrifuge modelling of an energy pile group with groundwater flow
    Ouzzine, Badr
    de Sauvage, Jean
    Madabhushi, Gopal
    Viggiani, Giulia
    Reiffsteck, Philippe
    INTERNATIONAL JOURNAL OF PHYSICAL MODELLING IN GEOTECHNICS, 2023, 24 (03) : 150 - 160
  • [9] Influence of backfilling phase change material on thermal performance of precast high-strength concrete energy pile
    Cao, Ziming
    Zhang, Guozhu
    Liu, Yiping
    Zhao, Xu
    Li, Chenglin
    RENEWABLE ENERGY, 2022, 184 : 374 - 390
  • [10] Investigation of groundwater flow and saturated multi-layer soil on the ground temperature response of an energy pile through thermal response and recovery testing
    Lines, Scott Harold
    Williams, David J.
    SOILS AND FOUNDATIONS, 2019, 59 (05) : 1359 - 1370