Evaluation of the Effects of Myopic Astigmatism Correction and Anterior Corneal Curvature on Functional Optical Zone After SMILE

被引:7
|
作者
Wang, Xueqing [1 ]
Xia, Likun [1 ]
机构
[1] China Med Univ, Shengjing Hosp, Shenyang, Liaoning, Peoples R China
关键词
INCISION LENTICULE EXTRACTION; IN-SITU KERATOMILEUSIS; ABLATION ZONE; ABERRATIONS; LASIK;
D O I
10.3928/1081597X-20221215-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the influence of different degrees of myopic astigmatism correction and preoperative anterior corneal curvature on the functional optical zone (FOZ) following small incision lenticule extraction (SMILE). METHODS: In this retrospective study, 68 patients (106 eyes) treated with SMILE were grouped according to myopic astigmatism correction: control (0.00 diopters [D]), moderate astigmatism (-0.50 to -2.00 D), and high astigmatism (> -2.00 D). The FOZ was measured and compared between the three groups for 3 months. Correlations between attempted correction, anterior corneal curvature, corneal aberrations, and the FOZ were analyzed. RESULTS: The preoperative mean treatment spherical equivalent was comparable among the three groups. The average FOZ was 5.06 +/- 0.24 mm in the control group, 5.19 +/- 0.25 mm in the moderate astigmatism group, and 5.35 +/- 0.20 mm in the high astigmatism group The FOZ showed statistically significant differences among the three groups (P <.001), particularly between the high astigmatism group and the other two groups (P <.001 and.018). Correlation analysis showed that the total higher order aberrations, coma, and spherical aberration change were correlated with the FOZ (P <.001). Preoperative steep keratometry, average keratometry, and corneal astigmatism were significantly correlated with the FOZ (P <.05). The correlation remained after excluding the influence of attempted correction on the FOZ (P <.05). After adjusting for other risk factors using multiple linear regression analysis, there was still a significant positive association between preoperative steep keratometry and the FOZ (P <.001). CONCLUSIONS: Patients with higher myopic astigmatism achieved a larger FOZ and less induced horizontal coma than the control and moderate astigmatism groups. A larger FOZ after SMILE can be achieved in eyes with steeper keratometry.
引用
收藏
页码:135 / +
页数:10
相关论文
共 29 条
  • [21] Prospective, Randomized, Contralateral Eye Comparison of Functional Optical Zone, and Visual Quality After SMILE and FS-LASIK for High Myopia
    He, Shengyu
    Luo, Yiqi
    Chen, Pei
    Ye, Yiming
    Zheng, Hua
    Lan, Min
    Zhuang, Jing
    Yu, Keming
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (02): : 1 - 12
  • [22] Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK
    Ying, Jinglu
    Cai, Jianqiu
    Zhu, Leru
    Zha, Yi
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [23] In Vivo Evaluation of the Effects of SMILE with Different Amounts of Stromal Ablation on Corneal Biomechanics by Optical Coherence Elastography
    Zhu, Yirui
    Zhao, Yanzhi
    Zhang, Yubao
    Yang, Hongwei
    Shi, Jiulin
    Cai, Hongling
    Zhang, Dong
    Huang, Guofu
    He, Xingdao
    Wu, Xiaoshan
    DIAGNOSTICS, 2023, 13 (01)
  • [24] Ten-year evaluation on efficacy, safety, and predictability of femtosecond laser corneal small incision lenticule extraction for correction of myopia and myopic astigmatism: a case series
    Zhao, Guo-Hong
    Zhang, Li-Jun
    Sun, Yan
    Wang, Jin-Da
    Chen, Chang-Xi
    Cao, Kai
    ANNALS OF MEDICINE AND SURGERY, 2024, 86 (11): : 6761 - 6765
  • [25] Theoretical Analysis of the Effect of Pupil Size, Initial Myopic Level, and Optical Zone on Quality of Vision After Corneal Refractive Surgery
    Alarcon, Aixa
    Rubino, Manuel
    Perez-Ocon, Francisco
    Jimenez, Jose R.
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (12) : 901 - 905
  • [26] Quantitative Evaluation of In Vivo Corneal Biomechanical Properties after SMILE and FLEx Surgery by Acoustic Radiation Force Optical Coherence Elastography
    Zhao, Yanzhi
    Zhu, Yirui
    Wang, Yongbo
    Yang, Hongwei
    He, Xingdao
    Alvarez-Arenas, Tomas Gomez
    Li, Yingjie
    Huang, Guofu
    SENSORS, 2023, 23 (01)
  • [27] Evaluation of Wide Corneal Epithelial Remodeling after Small Incision Lenticule Extraction (SMILE) with Wide-Field Optical Coherence Tomography
    Ye, Yiming
    Chen, Pei
    Yu, Na
    Wan, Linxi
    Lan, Min
    Zheng, Hua
    Yu, Keming
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [28] Intrastromal Corneal Ring Segments Implantation After Deep Anterior Lamellar Keratoplasty for Astigmatism Correction: Mid-term and Long-term Follow-up
    Alfonso-Bartolozzi, Belen
    Fernandez-Vega-Cueto, Luis
    Poo-Lopez, Aranzazu
    Lisa, Carlos
    Madrid-Costa, David
    Alfonso, Jose F.
    CORNEA, 2023, 42 (08) : 962 - 969
  • [29] Intraocular lens power calculation after previous myopic laser vision correction based on corneal power measured by Fourier-domain optical coherence tomography
    Tang, Maolong
    Wang, Li
    Koch, Douglas D.
    Li, Yan
    Huang, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (04) : 589 - 594