Effect of Axial Flow Blood Pump's Pulsation Speed Regulation on Key Hemodynamic Parameters

被引:0
|
作者
Wang, Shuai [1 ]
Wang, Hao [1 ]
Yu, Zheqin [2 ]
Tan, Jianping [3 ]
Li, Geqiang [1 ]
Guo, Bin [1 ]
机构
[1] Henan Univ Sci & Technol, Sch Mech & Elect Engn, Luoyang 471003, Peoples R China
[2] Changsha Univ Sci & Technol, Coll Energy & Power Engn, Changsha, Peoples R China
[3] Cent South Univ, Coll Mech & Elect Engn, Changsha 410083, Peoples R China
关键词
Blood pump; pulsation; speed regulation; lumped parameter model; hemodynamics; physiological synchronization; VENTRICULAR ASSIST DEVICE;
D O I
10.1142/S021951942340064X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Implantation of the blood pump is an important method to treat heart failure (HF) at present. Many studies have shown that the pressure waveform produced by the constant speed of the rotary blood pump lacks fluctuation, which may cause a series of body damage. Therefore, it is believed that it is beneficial for the body to produce higher pressure fluctuation by rapidly adjusting the speed of the blood pump, but how to set the parameters in the speed waveform is a big challenge. The purpose of this study is to obtain the regularity of the blood pump's changing speed on hemodynamics. In this study, a lumped parameter coupling model of the blood pump and cardiovascular system was established, and the blood pump model was improved by introducing the pulsation characteristic component. A velocity regulation waveform that is consistent with the trend of the ventricular activation function was selected. The effects of different speed control parameters on hemodynamic parameters were analyzed, and comparisons with the constant speed were made. The results show that the pulse pressure (PP) is higher at variable speed. The hemolysis value under variable speed is higher than constant speed, and increases with the decreases of speed modulation frequency. We also found that the PP will increase with the decrease of the speed control frequency. To explain this phenomenon, a dimensionless parameter S that combines the integral of the speed pulsation amplitude with the modulation cycle and the heartbeat cycle was proposed. By comparing the S and PP values, it shows that the change rules of the two are compatible. Therefore, the speed modulation of the blood pump should also consider the integral effect of the rotation speed in the cardiac cycle.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] An in silico analysis of unsteady flow structures in a microaxial blood pump under a pulsating rotation speed
    Chen, Chenghan
    Zhang, Mingkui
    Hao, Pengfei
    He, Feng
    Zhang, Xiwen
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 243
  • [32] Nonlinear mathematical analysis of the hemodynamic parameters during left ventricular assistance with oscillated blood flow
    Yambe, T
    Kobayashi, S
    Sonobe, T
    Naganuma, S
    Nanka, S
    Hashimoto, H
    Yoshizawa, M
    Tabayashi, K
    Takayasu, H
    Takeda, H
    Nitta, S
    ARTIFICIAL ORGANS, 1997, 21 (07) : 625 - 629
  • [33] Hemodynamic Effect of Pulsatile on Blood Flow Distribution with VA ECMO: A Numerical Study
    Gu, Kaiyun
    Gao, Sizhe
    Zhang, Zhe
    Ji, Bingyang
    Chang, Yu
    BIOENGINEERING-BASEL, 2022, 9 (10):
  • [34] Restoring pulsatility and peakVO2 in the era of continuous flow, fixed pump speed, left ventricular assist devices: 'A hypothesis of pump's or patient's speed?'
    Laoutaris, Ioannis D.
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2019, 26 (17) : 1806 - 1815
  • [35] Effect of rotary blood pump pulsatility on potential parameters of blood compatibility and thrombosis in inflow cannula tips
    Wong, Kai Chun
    Buesen, Martin
    Benzinger, Carrie
    Gaeng, Rene
    Bezema, Mirko
    Greatrex, Nicholas
    Schmitz-Rode, Thomas
    Steinseifer, Ulrich
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2014, 37 (12) : 875 - 887
  • [36] Effect of Latanoprost on Choroidal Blood Flow Regulation in Healthy Subjects
    Boltz, Agnes
    Schmidl, Doreen
    Weigert, Guenther
    Lasta, Michael
    Pemp, Berthold
    Resch, Hemma
    Garhoefer, Gerhard
    Fuchsjaeger-Mayrl, Gabriele
    Schmetterer, Leopold
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) : 4410 - 4415
  • [37] Study on the influence of dynamic/static interface processing methods on CFD simulation results of the axial-flow blood pump
    Wang, Shuai
    Tan, Jianping
    Yu, Zheqin
    ADVANCES IN MECHANICAL ENGINEERING, 2020, 12 (03)
  • [38] Speed Modulation of the HeartWare HVAD to Assess In Vitro Hemocompatibility of Pulsatile and Continuous Flow Regimes in a Rotary Blood Pump
    Horobin, Jarod T.
    Simmonds, Michael J.
    Nandakumar, Deepika
    Gregory, Shaun D.
    Tansley, Geoff
    Pauls, Jo P.
    Girnghuber, Angela
    Balletti, Nicoletta
    Fraser, John F.
    ARTIFICIAL ORGANS, 2018, 42 (09) : 879 - 890
  • [39] Exercise Capacity in Patients Supported With Rotary Blood Pumps Is Improved by a Spontaneous Increase of Pump Flow at Constant Pump Speed and by a Rise in Native Cardiac Output
    Jacquet, Luc
    Vancaenegem, Olivier
    Pasquet, Agnes
    Matte, Pascal
    Poncelet, Alain
    Price, Joel
    Gurne, Olivier
    Noirhomme, Philippe
    ARTIFICIAL ORGANS, 2011, 35 (07) : 682 - 690
  • [40] Experimental Study of Micro-Scale Taylor Vortices Within a Co-Axial Mixed-Flow Blood Pump
    Shu, Fangjun
    Tian, Ruijun
    Vandenberghe, Stijn
    Antaki, James F.
    ARTIFICIAL ORGANS, 2016, 40 (11) : 1071 - 1078