Effect of Axial Flow Blood Pump's Pulsation Speed Regulation on Key Hemodynamic Parameters

被引:0
|
作者
Wang, Shuai [1 ]
Wang, Hao [1 ]
Yu, Zheqin [2 ]
Tan, Jianping [3 ]
Li, Geqiang [1 ]
Guo, Bin [1 ]
机构
[1] Henan Univ Sci & Technol, Sch Mech & Elect Engn, Luoyang 471003, Peoples R China
[2] Changsha Univ Sci & Technol, Coll Energy & Power Engn, Changsha, Peoples R China
[3] Cent South Univ, Coll Mech & Elect Engn, Changsha 410083, Peoples R China
关键词
Blood pump; pulsation; speed regulation; lumped parameter model; hemodynamics; physiological synchronization; VENTRICULAR ASSIST DEVICE;
D O I
10.1142/S021951942340064X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Implantation of the blood pump is an important method to treat heart failure (HF) at present. Many studies have shown that the pressure waveform produced by the constant speed of the rotary blood pump lacks fluctuation, which may cause a series of body damage. Therefore, it is believed that it is beneficial for the body to produce higher pressure fluctuation by rapidly adjusting the speed of the blood pump, but how to set the parameters in the speed waveform is a big challenge. The purpose of this study is to obtain the regularity of the blood pump's changing speed on hemodynamics. In this study, a lumped parameter coupling model of the blood pump and cardiovascular system was established, and the blood pump model was improved by introducing the pulsation characteristic component. A velocity regulation waveform that is consistent with the trend of the ventricular activation function was selected. The effects of different speed control parameters on hemodynamic parameters were analyzed, and comparisons with the constant speed were made. The results show that the pulse pressure (PP) is higher at variable speed. The hemolysis value under variable speed is higher than constant speed, and increases with the decreases of speed modulation frequency. We also found that the PP will increase with the decrease of the speed control frequency. To explain this phenomenon, a dimensionless parameter S that combines the integral of the speed pulsation amplitude with the modulation cycle and the heartbeat cycle was proposed. By comparing the S and PP values, it shows that the change rules of the two are compatible. Therefore, the speed modulation of the blood pump should also consider the integral effect of the rotation speed in the cardiac cycle.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Measurement of hemodynamic changes with the axial flow blood pump installed in descending aorta
    Eiji Okamoto
    Tetsuya Yano
    Hidekazu Miura
    Yasuyuki Shiraishi
    Tomoyuki Yambe
    Yoshinori Mitamura
    Journal of Artificial Organs, 2017, 20 : 390 - 393
  • [2] Measurement of hemodynamic changes with the axial flow blood pump installed in descending aorta
    Okamoto, Eiji
    Yano, Tetsuya
    Miura, Hidekazu
    Shiraishi, Yasuyuki
    Yambe, Tomoyuki
    Mitamura, Yoshinori
    JOURNAL OF ARTIFICIAL ORGANS, 2017, 20 (04) : 390 - 393
  • [3] Miniaturization of a Magnetically Levitated Axial Flow Blood Pump
    Cheng, Shanbao
    Olles, Mark W.
    Olsen, Don B.
    Joyce, Lyle D.
    Day, Steven W.
    ARTIFICIAL ORGANS, 2010, 34 (10) : 807 - 815
  • [4] Effect of Conical Spiral Flow Channel and Impeller Parameters on Flow Field and Hemolysis Performance of an Axial Magnetic Blood Pump
    Yang, Wei-Bo
    Zhou, Jian
    Xiao, Wei-Hu
    Peng, Si-Jie
    Hu, Ye-Fa
    Li, Ming
    Wu, Hua-Chun
    PROCESSES, 2022, 10 (05)
  • [5] Influence of Impeller Speed Patterns on Hemodynamic Characteristics and Hemolysis of the Blood Pump
    Wang, Yiwen
    Shen, Peng
    Zheng, Minli
    Fu, Pengqiang
    Liu, Lijia
    Wang, Jingyue
    Yuan, Lishan
    APPLIED SCIENCES-BASEL, 2019, 9 (21):
  • [6] Hemodynamic Performance of a Miniature Axial Blood Pump Caused by Motors
    Chang, Yu
    Chen, Ningning
    Gao, Bin
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1250 - 1253
  • [7] Mechanical axial flow blood pump to support cavopulmonary circulation
    Throckmorton, A. L.
    Kapadia, J.
    Madduri, D.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (11) : 970 - 982
  • [8] Experimental investigation of the influence of the hydraulic performance of an axial blood pump on intraventricular blood flow
    Liu, Guang-Mao
    Jiang, Fu-Qing
    Yang, Xiao-Han
    Wei, Run-Jie
    Hu, Sheng-Shou
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2021, 44 (12) : 980 - 989
  • [9] Flow Visualization in the Outflow Cannula of an Axial Blood Pump
    Liu, Guangmao
    Zhang, Yan
    Chen, Haibo
    Sun, Hansong
    Zhou, Jianye
    Hu, Shengshou
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 117 - 122
  • [10] EFFECT OF HEMODYNAMIC PARAMETERS ON FRACTIONAL FLOW RESERVE
    Feng, Yue
    Mao, Boyan
    Li, Bao
    Liu, Jian
    Liu, Jincheng
    Liu, Youjun
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2020, 20 (03)