Experimental research on the thermal characteristic of low-voltage alternating current (AC) arc faults

被引:15
作者
Ge, Fanliang [1 ]
Qiu, Tingting [1 ]
Zhang, Mengsi [1 ]
Ji, Jie [1 ,2 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, MEM Key Lab Forest Fire Monitoring & Warning, Hefei 230026, Anhui, Peoples R China
关键词
Electrical fires; Arc faults; Low-voltage circuit; Thermal characteristic; PVC coated wire; CIRCUIT;
D O I
10.1016/j.firesaf.2022.103732
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objective of this paper is to study the thermal characteristic of low-voltage alternating current (AC) arc faults. Two series of experiments were designed, including polyvinyl chloride (PVC) wire ignitions experiments and electrode arcing experiments (non-ignitions) subjected to arc faults at different effective currents. The ignition time of the wire and the temperature of the electrode were investigated to characterize the arcing hazard. Results show that the ignition time of the wire decreases with the increasing arc current, and the wire with a larger cross-section area requires more time to be ignited at the same current. For non-ignition experi- ments, the electrode temperature increases first and then varies little. A heat equilibrium stage can be reached, where the heat transfer of the arc to the electrode is equal to the heat dissipation of the electrode. Furthermore, a heat transfer model for the arc fault is established to obtain the electrode temperature. The temperature of the arc-electrode interface is used to characterize the arc energy, and it is found the temperature showed a loga- rithmic increase with the current. The results of this study may be useful in the safety design of electrical wires, and can be exploited as hazard indicators for the risk assessment of electrical fires.
引用
收藏
页数:8
相关论文
共 26 条
[1]  
Abe T., 2016, P IEEE C EL INS DIEL
[2]  
Babraukas V., 2008, P 9 INT S FIRE SAFET, P3
[3]  
Babrauskas V., 2001, Proc. Fire and Materials 2001 Conf, P39
[4]  
Babrauskas V., 2016, SFPE Handb. Fire Prot. Eng., Vfifth, P952, DOI [DOI 10.1007/978-1-4939-2565-0_28, 10.1007/978-1-4939-2565-0_28, 10.1007/978-1-4939-2565-0, DOI 10.1007/978-1-4939-2565-0]
[5]  
Babrauskas V., 2021, ELECT FIRES EXPLOSIO
[6]  
Campbell R., 2019, HOME ELECT FIRES SUP, V3/19
[7]   An experimental study on the thermal characteristics and heating effect of arc-fault from Cu core in residential electrical wiring fires [J].
Du, Jian-Hua ;
Tu, Ran ;
Zeng, Yi ;
Pan, Leng ;
Zhang, Ren-Cheng .
PLOS ONE, 2017, 12 (08)
[8]  
Fire and Rescue Department Ministry of Emergency Management, 2021, NAT FIR STAT 2020
[9]   The arc-fault circuit interrupter: An emerging product [J].
Gregory, GD ;
Scott, GW .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (05) :928-933
[10]   Ignition-to-spread transition of externally heated electrical wire [J].
Huang, Xinyan ;
Nakamura, Yuji ;
Williams, Forman A. .
PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2013, 34 :2505-2512