Dose Distribution of High Dose-Rate and Low Dose-Rate Prostate Brachytherapy at Different Intervals-Impact of a Hydrogel Spacer and Prostate Volume

被引:1
作者
Haddad, Hathal [1 ]
Hermani, Horst [1 ]
Hanitzsch, Herbert [2 ,3 ]
Heidrich, Albert [2 ,4 ]
Pinkawa, Michael [1 ]
机构
[1] MediClin Robert Janker Klin, Dept Radiat Oncol, D-53129 Bonn, Germany
[2] MediClin Robert Janker Klin, Dept Urol, D-53129 Bonn, Germany
[3] Urol Ctr Bonn, D-53111 Bonn, Germany
[4] Curos Urol Ctr, D-50389 Wesseling, Germany
关键词
prostate cancer; interstitial brachytherapy; I-125; Ir-192; dosimetry; spacer; EXTERNAL-BEAM RADIATION; HDR BRACHYTHERAPY; RECTUM SPACER; CANCER; RADIOTHERAPY; MONOTHERAPY; TOXICITY; OUTCOMES; INTERMEDIATE; DOSIMETRY;
D O I
10.3390/cancers15051396
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Two different prostate brachytherapy methods are applied to treat prostate cancer: either a permanent implant of low-dose-rate (LDR-BT) sources or a temporary implant of high-dose-rate (HDR-BT) sources. This study aimed to compare the dose distributions, specifically focusing on the impact of a prostate-rectum spacer and prostate volume. The prostate dose coverage was comparable between different techniques. HDR-BT was characterized by a considerably more homogenous dose distribution and lower doses to the urethra. The minimum dose of up to 5 mm from the prostate was higher for larger prostates. As a consequence of the hydrogel spacer in HDR-BT patients, the intraoperative rectum dose was considerably lower, especially in smaller prostates. However, prostate volume dose coverage was not improved. The dosimetric results explain the clinical differences between the techniques reported in the literature. The study aimed to compare the dose distribution in permanent low-dose-rate brachytherapy (LDR-BT) and high-dose-rate brachytherapy (HDR-BT), specifically focusing on the impact of a spacer and prostate volume. The relative dose distribution of 102 LDR-BT patients (prescription dose 145 Gy) at different intervals was compared with the dose distribution of 105 HDR-BT patients (232 HDR-BT fractions with prescription doses of 9 Gy, n = 151, or 11.5 Gy, n = 81). A hydrogel spacer (10 mL) was only injected before HDR-BT. For the analysis of dose coverage outside the prostate, a 5 mm margin was added to the prostate volume (PV+). Prostate V100 and D90 of HDR-BT and LDR-BT at different intervals were comparable. HDR-BT was characterized by a considerably more homogenous dose distribution and lower doses to the urethra. The minimum dose in 90% of PV+ was higher for larger prostates. As a consequence of the hydrogel spacer in HDR-BT patients, the intraoperative dose at the rectum was considerably lower, especially in smaller prostates. However, prostate volume dose coverage was not improved. The dosimetric results well explain clinical differences between these techniques reported in the literature review, specifically comparable tumor control, higher acute urinary toxicity rates in LDR-BT in comparison to HDR-BT, decreased rectal toxicity after spacer placement, and improved tumor control after HDR-BT in larger prostate volumes.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A radiobiological study of the schemes with a low number of fractions in high-dose-rate brachytherapy as monotherapy for prostate cancer
    Guirado, Damian
    Ruiz-Arrebola, Samuel
    Tornero-Lopez, Ana M.
    de la Vega, Jose M.
    Prada, Pedro J.
    Lallena, Antonio M.
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2020, 12 (02) : 193 - 200
  • [42] Urethral stricture following high dose rate brachytherapy for prostate cancer
    Sullivan, Lisa
    Williams, Scott G.
    Tai, Keen Hun
    Foroudi, Farshad
    Cleeve, L.
    Duchesne, Gillian M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 91 (02) : 232 - 236
  • [43] High dose rate brachytherapy boost for prostate cancer: A systematic review
    Zaorsky, Nicholas G.
    Doyle, Laura A.
    Yamoah, Kosj
    Andrel, Jocelyn A.
    Trabulsi, Edouard J.
    Hurwitz, Mark D.
    Dicker, Adam P.
    Den, Robert B.
    CANCER TREATMENT REVIEWS, 2014, 40 (03) : 414 - 425
  • [44] Low-dose-rate or high-dose-rate brachytherapy in treatment of prostate cancer - between options
    Skowronek, Janusz
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (01) : 33 - 41
  • [45] High-dose-rate brachytherapy as monotherapy for prostate cancer
    Demanes, D. Jeffrey
    Ghilezan, Michel I.
    BRACHYTHERAPY, 2014, 13 (06) : 529 - 541
  • [46] Role of high dose rate brachytherapy in the treatment of prostate cancer
    Ghilezan, M.
    CANCER RADIOTHERAPIE, 2012, 16 (5-6): : 418 - 422
  • [47] Justification for inter-fraction correction of catheter movement in fractionated high dose-rate brachytherapy treatment of prostate cancer
    Simnor, Tania
    Li, Sonia
    Lowe, Gerry
    Ostler, Peter
    Bryant, Linda
    Chapman, Caroline
    Inchley, Dave
    Hoskin, Peter J.
    RADIOTHERAPY AND ONCOLOGY, 2009, 93 (02) : 253 - 258
  • [48] High dose rate brachytherapy for prostate cancer
    Hoskin, P.
    CANCER RADIOTHERAPIE, 2008, 12 (6-7): : 512 - 514
  • [49] BrachyView: Proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy
    Petasecca, M.
    Loo, K. J.
    Safavi-Naeini, M.
    Han, Z.
    Metcalfe, P. E.
    Meikle, S.
    Pospisil, S.
    Jakubek, J.
    Bucci, J. A.
    Zaider, M.
    Lerch, M. L. F.
    Qi, Y.
    Rosenfeld, A. B.
    MEDICAL PHYSICS, 2013, 40 (04)
  • [50] Counterpoint: There is a dose-response relationship in the low-dose rate brachytherapy management of prostate cancer
    Stock, Richard G.
    BRACHYTHERAPY, 2010, 9 (04) : 293 - 296