Screen-printed electrochemical sensors for label-free potentiometric and impedimetric detection of human serum albumin

被引:5
|
作者
Kamel, Ayman H. [1 ,2 ,5 ]
Ashmawy, Nashwa H. [1 ]
Youssef, Teraze A. [1 ]
Elnakib, Mostafa [3 ]
Abd El-Naby, Heba [1 ]
Abd-Rabboh, Hisham S. M. [4 ,6 ]
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
[2] Coll Sci, Chem Dept, Sakhir, Bahrain
[3] Mil Med Acad, Elkhalifa, Cairo, Egypt
[4] King Khalid Univ, Fac Sci, Chem Dept, Abha, Saudi Arabia
[5] Ain Shams Univ, Fac Sci, Dept Chem, Cairo 11566, Egypt
[6] King Khalid Univ, Fac Sci, Chem Dept, Abha 61413, Saudi Arabia
关键词
albumin; biological fluids; disposable diagnostics; electrochemical sensors; multi-walled carbon nanotubes (MWCNTs); screen printed electrodes; ION-SELECTIVE ELECTRODES; HPLC METHOD; BIOSENSOR; GRAPHENE; URINE; STEP; HSA;
D O I
10.1002/elan.202200436
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, two electrochemical methods based on potentiometric and impedimetric transductions were presented for albumin targeting, employing screen-printed platforms (SPEs) to make easy and cost-effective sensors with good detection merits. The SPEs incorporated ion-to-electron multi-walled carbon nanotubes (MWCNTs) transducer. Sensors were constructed using either tridodecyl methyl-ammonium chloride (TDMACl) (sensor I) or aliquate 336S (sensor II) in plasticized polymeric matrices of carboxylated poly (vinyl chloride) (PVC-COOH). Analytical performances of the sensors were evaluated using the above-mentioned electrochemical techniques. For potentiometric assay, constructed sensors responded to albumin with -81.7 +/- 1.7 (r(2) = 0.9986) and -146.2 +/- 2.3 mV/decade (r(2) = 0.9991) slopes over the linearity range 1.5 mu M-1.5 mM with 0.8 and 1.0 mu M detection limits for respective TDMAC- and aliquate-based sensors. Interference study showed apparent selectivity for both sensors. Impedimetric assays were performed at pH = 7.5 in 10 mM PBS buffer solution with a 0.02 M [Fe(CN)(6)](-3/-4) redox-active electrolyte. Sensors achieved detection limits of 4.3 x 10(-8) and 1.8 x 10(-7) M over the linear ranges of 5.2x10(-8)-1.0x10(-4) M and 1.4x10(-6)-1.4x10(-3) M, with 0.09 +/- 0.004 and 0.168 +/- 0.009 log omega/decade slopes for sensors based on TDMAC and aliquate, respectively. These sensors are characterized with simple construction, high sensitivity and selectivity, fast response time, single-use, and cost-effectiveness. The methods were successfully applied to albumin assessment in different biological fluids.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] AuNPs/PpPD/PEDOT:PSS-Fc modified screen-printed carbon electrode label-free immunosensor for sensitive and selective determination of human serum albumin
    Choosang, Jittima
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    MICROCHEMICAL JOURNAL, 2020, 155
  • [22] Carbon nanotube screen-printed electrochemical sensors
    Wang, J
    Musameh, M
    ANALYST, 2004, 129 (01) : 1 - 2
  • [23] Label-free Detection of Prostate Specific Antigen at a Screen-printed Immunosensor Modified with a Nanostructured Gold Layer
    Rawlinson, Sean
    Kanyong, Prosper
    McConville, Aaron
    Fearon, John-Joe
    McLaughlin, James A. D.
    Davis, James
    CHEMISTRY LETTERS, 2017, 46 (12) : 1728 - 1731
  • [24] Electrochemical (Bio)Sensors for Pesticides Detection Using Screen-Printed Electrodes
    Perez-Fernandez, Beatriz
    Costa-Garcia, Agustin
    de la Escosura-Muniz, Alfredo
    BIOSENSORS-BASEL, 2020, 10 (04):
  • [25] Recent progress in screen-printed electrochemical sensors and biosensors for the detection of estrogens
    Musa, Auwal M.
    Kiely, Janice
    Luxton, Richard
    Honeychurch, Kevin C.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 139
  • [26] A label-free electrochemical biosensor for the detection of alpha-thalassemia 1 (SEA deletion) carriers using screen-printed carbon electrodes
    Thamwarokun A.
    Kaset C.
    Karuwan C.
    Kamsong W.
    Attapong J.
    Chomean S.
    Biosensors and Bioelectronics: X, 2023, 14
  • [27] Probeless and label-free impedimetric biosensing of D-dimer using gold nanoparticles conjugated with dihexadecylphosphate on screen-printed carbon electrodes
    Tasic, Nikola
    Cavalcante, Leticia
    Deffune, Elenice
    Goes, Marcio Sousa
    Paixao, Thiago R. L. C.
    Goncalves, Luis Moreira
    ELECTROCHIMICA ACTA, 2021, 397
  • [28] Label-free human chorionic gonadotropin detection at picogram levels using oriented antibodies bound to graphene screen-printed electrodes
    Teixeira, Sofia
    Conlan, Robert S.
    Guy, O. J.
    Sales, M. Goreti F.
    JOURNAL OF MATERIALS CHEMISTRY B, 2014, 2 (13) : 1852 - 1865
  • [29] Impedimetric Screen-Printed Immunosensor for the Rapid Detection of Chagas Disease
    Chain, Cecilia Y.
    Franchin, Lara
    Cisneros, Jose S.
    Villagra, Andrea P. M.
    Labriola, Carlos A.
    Paccagnella, Alessandro
    Bonaldo, Stefano
    IEEE SENSORS JOURNAL, 2024, 24 (02) : 1167 - 1174
  • [30] Reusable potentiometric screen-printed sensor and label-free aptasensor with pseudo-reference electrode for determination of tryptophan in the presence of tyrosine
    Majidi, Mir Reza
    Omidi, Yadollah
    Karami, Pari
    Johari-Ahar, Mohammad
    TALANTA, 2016, 150 : 425 - 433