Screen-printed electrochemical sensors for label-free potentiometric and impedimetric detection of human serum albumin

被引:5
|
作者
Kamel, Ayman H. [1 ,2 ,5 ]
Ashmawy, Nashwa H. [1 ]
Youssef, Teraze A. [1 ]
Elnakib, Mostafa [3 ]
Abd El-Naby, Heba [1 ]
Abd-Rabboh, Hisham S. M. [4 ,6 ]
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
[2] Coll Sci, Chem Dept, Sakhir, Bahrain
[3] Mil Med Acad, Elkhalifa, Cairo, Egypt
[4] King Khalid Univ, Fac Sci, Chem Dept, Abha, Saudi Arabia
[5] Ain Shams Univ, Fac Sci, Dept Chem, Cairo 11566, Egypt
[6] King Khalid Univ, Fac Sci, Chem Dept, Abha 61413, Saudi Arabia
关键词
albumin; biological fluids; disposable diagnostics; electrochemical sensors; multi-walled carbon nanotubes (MWCNTs); screen printed electrodes; ION-SELECTIVE ELECTRODES; HPLC METHOD; BIOSENSOR; GRAPHENE; URINE; STEP; HSA;
D O I
10.1002/elan.202200436
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, two electrochemical methods based on potentiometric and impedimetric transductions were presented for albumin targeting, employing screen-printed platforms (SPEs) to make easy and cost-effective sensors with good detection merits. The SPEs incorporated ion-to-electron multi-walled carbon nanotubes (MWCNTs) transducer. Sensors were constructed using either tridodecyl methyl-ammonium chloride (TDMACl) (sensor I) or aliquate 336S (sensor II) in plasticized polymeric matrices of carboxylated poly (vinyl chloride) (PVC-COOH). Analytical performances of the sensors were evaluated using the above-mentioned electrochemical techniques. For potentiometric assay, constructed sensors responded to albumin with -81.7 +/- 1.7 (r(2) = 0.9986) and -146.2 +/- 2.3 mV/decade (r(2) = 0.9991) slopes over the linearity range 1.5 mu M-1.5 mM with 0.8 and 1.0 mu M detection limits for respective TDMAC- and aliquate-based sensors. Interference study showed apparent selectivity for both sensors. Impedimetric assays were performed at pH = 7.5 in 10 mM PBS buffer solution with a 0.02 M [Fe(CN)(6)](-3/-4) redox-active electrolyte. Sensors achieved detection limits of 4.3 x 10(-8) and 1.8 x 10(-7) M over the linear ranges of 5.2x10(-8)-1.0x10(-4) M and 1.4x10(-6)-1.4x10(-3) M, with 0.09 +/- 0.004 and 0.168 +/- 0.009 log omega/decade slopes for sensors based on TDMAC and aliquate, respectively. These sensors are characterized with simple construction, high sensitivity and selectivity, fast response time, single-use, and cost-effectiveness. The methods were successfully applied to albumin assessment in different biological fluids.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Impedimetric Label-Free Immunosensor on Disposable Modified Screen-Printed Electrodes for Ochratoxin A
    Malvano, Francesca
    Albanese, Donatella
    Crescitelli, Alessio
    Pilloton, Roberto
    Esposito, Emanuela
    BIOSENSORS-BASEL, 2016, 6 (03):
  • [2] Label-free detection of cytochrome C by a conducting polymer-based impedimetric screen-printed aptasensor
    Shafaat, Atefeh
    Faridbod, Farnoush
    Ganjali, Mohammad Reza
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (08) : 6034 - 6039
  • [3] Label-free impedimetric aptasensor for lysozyme detection based on carbon nanotube-modified screen-printed electrodes
    Rohrbach, Falk
    Karadeniz, Hakan
    Erdem, Arzum
    Famulok, Michael
    Mayer, Guenter
    ANALYTICAL BIOCHEMISTRY, 2012, 421 (02) : 454 - 459
  • [4] A carbon nanotube screen-printed electrode for label-free detection of the human cardiac troponin T
    Silva, Barbara V. M.
    Cavalcanti, Igor T.
    Silva, Mizia M. S.
    Dutra, Rosa F.
    TALANTA, 2013, 117 : 431 - 437
  • [5] Biolayer-Interferometry-Guided Functionalization of Screen-Printed Graphene for Label-Free Electrochemical Virus Detection
    Szydlowska, Beata M.
    Pola, Cicero C.
    Cai, Zizhen
    Chaney, Lindsay E.
    Hui, Janan
    Sheets, Robert
    Carpenter, Jeremiah
    Dean, Delphine
    Claussen, Jonathan C.
    Gomes, Carmen L.
    Hersam, Mark C.
    ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (19) : 25169 - 25180
  • [6] Label-free electrochemical impedimetric immunosensor for sensitive detection of IgM rheumatoid factor in human serum
    Chinnadayyala, Somasekhar R.
    Park, Jinsoo
    Abbasi, Muhammad A.
    Choa, Sungbo
    BIOSENSORS & BIOELECTRONICS, 2019, 143
  • [7] Highly Sensitive Label-Free Electrochemical Aptasensor Based on Screen-Printed Electrode for Detection of Cadmium (II) Ions
    Li, Yu
    Ran, Guojing
    Lu, Gen
    Ni, Xinyu
    Liu, Daling
    Sun, Jianxia
    Xie, Chunfang
    Yao, Dongsheng
    Bai, Weibin
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (06) : B449 - B455
  • [8] Novel naproxenate screen-printed potentiometric sensors
    Khaled, Elmorsy
    Shoukry, Eman M.
    Amin, Mona F.
    Said, Basmat A. M.
    Abd-Elmonem, Mahmmoud S.
    EGYPTIAN PHARMACEUTICAL JOURNAL, 2018, 17 (03) : 201 - 211
  • [9] Label-Free Detection of Hemoglobin Using MWNT-Embedded Screen-Printed Electrode
    Bhatnagar D.
    Tuteja S.K.
    Rastogi R.
    Bharadwaj L.M.
    BioNanoScience, 2013, 3 (3) : 223 - 231
  • [10] A label-free Electrochemical Immunosensor Based on Polythionine-nanogold Nanocomposite for Detection of Trypsin Using screen-printed Electrode
    Hu, Jianxiong
    Li, Quwen
    Chen, Jianhui
    Chen, Shijun
    Cai, Yangfang
    Zhao, Chengfei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06):