Effectiveness of Implantable Cardioverter Defibrillator in Patients With Non-Ischemic Heart Failure With Systolic Dysfunction

被引:4
|
作者
Sasaki, Shingo [1 ]
Noda, Takashi [2 ]
Okumura, Ken [3 ]
Nitta, Takashi [4 ]
Aizawa, Yoshifusa [5 ]
Ohe, Tohru [6 ]
Kurita, Takashi [7 ]
机构
[1] Hirosaki Univ, Dept Cardiol & Nephrol, Grad Sch Med, 5 Zaifu Cho, Hirosaki, Aomori 0368562, Japan
[2] Tohoku Univ, Dept Cardiovasc Med, Grad Sch Med, Sendai, Miyagi, Japan
[3] Saiseikai Kumamoto Hosp, Adv Arrhythmia Therapeut Branch Div Cardiol, Cardiovasc Ctr, Kumamoto, Japan
[4] Hanyu Gen Hosp, Dept Cardiovasc Surg, Saitama, Japan
[5] Tachikawa Med Ctr, Dept Res & Dev, Niigata, Japan
[6] Okayama City Hosp, Okayama, Japan
[7] Kindai Univ, Fac Med, Dept Internal Med, Osaka, Japan
关键词
Electrical storm; Implantable cardioverter-defibrillator; Non-ischemic heart failure; Propensity score matching; Prophylactic implantable cardioverter defibrillator (ICD) therapy; PRIMARY PREVENTION; PROPHYLACTIC IMPLANTATION; NON-PHARMACOTHERAPY; ELECTRICAL STORM; THERAPY; DEATH; RISK; ARRHYTHMIAS; MORTALITY; DISEASE;
D O I
10.1253/circj.CJ-22-0187
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The prospective observational Nippon Storm Study aggregated clinical data from Japanese patients receiving implant-able cardioverter-defibrillator (ICD) therapy. This study investigated the usefulness of prophylactic ICD therapy in patients with non-ischemic heart failure (NIHF) enrolled in the study. Methods and Results: We analyzed 540 NIHF patients with systolic dysfunction (left ventricular ejection fraction <50%). Propensity score matching was used to select patient subgroups for comparison; 126 patients were analyzed in each of the primary (PP) and secondary (SP) prophylaxis groups. The incidence of appropriate ICD therapy during follow-up in the PP and SP groups was 21.4% and 31.7%, respectively (P=0.044). The incidence of electrical storm (ES) was higher in SP than PP patients (P=0.024). Cox pro-portional hazard analysis revealed that increased serum creatinine in SP patients (hazard ratio [HR] 1.18; 95% confidence interval [CI] 1.02-1.33; P=0.013) and anemia in PP patients (HR 0.92; 95% CI 0.86-0.98; P=0.008) increased the likelihood of appropriate ICD therapy, whereas long-lasting atrial fibrillation in PP patients (HR, 0.64 [95% CI, 0.45-0.91], P=0.013) decreased that likelihood. Conclusions: In propensity score-matched Japanese NIHF patients, the incidence of appropriate ICD therapy and ES was signifi-cantly higher in SP than PP patients. Impaired renal function in SP patients and anemia in PP patients increased the likelihood of appropriate ICD therapy, whereas long-lasting atrial fibrillation reduced that likelihood in PP patients.
引用
收藏
页码:92 / 100
页数:9
相关论文
共 50 条
  • [1] Predictors of ventricular tachyarrhythmia in patients with implantable cardioverter-defibrillator and non-ischemic systolic heart failure
    Jedrzejczyk-Patej, Ewa
    Mazurek, Michal
    Lazar, Monika
    Pruszkowska-Skrzep, Patrycja
    Sokal, Adam
    Kowalczyk, Jacek
    Kowalski, Oskar
    Kalarus, Zbigniew
    Lenarczyk, Radoslaw
    KARDIOLOGIA POLSKA, 2023, 81 (10) : 998 - 1005
  • [2] Effectiveness of Implantable Cardioverter-Defibrillator Therapy for Heart Failure Patients according to Ischemic or Non-Ischemic Etiology in Korea
    Park, Kyu-Hwan
    Lee, Chan-Hee
    Jung, Byung Chun
    Cho, Yongkeun
    Bae, Myung Hwan
    Kim, Yoon-Nyun
    Park, Hyoung-Seob
    Han, Seongwook
    Lee, Young Soo
    Hyun, Dae-Woo
    Kim, Jun
    Kim, Dae Kyeong
    Cha, Tae-Jun
    Shin, Dong-Gu
    KOREAN CIRCULATION JOURNAL, 2017, 47 (01) : 72 - 81
  • [3] Survival and arrhythmic risk among ischemic and non-ischemic heart failure patients with prophylactic implantable cardioverter defibrillator only therapy: A propensity score-matched analysis
    Briongos-Figuero, Sem
    Estevez, Alvaro
    Luisa Perez, M.
    Martinez-Ferrer, Jose B.
    Garcia, Enrique
    Vinolas, Xavier
    Arenal, Angel
    Alzueta, Javier
    Basterra, Nuria
    Rodriguez, Anibal
    Lozano, Ignacio
    Munoz-Aguilera, Roberto
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 274 : 163 - 169
  • [4] Mortality among ischemic and nonischemic heart failure patients with a primary implantable cardioverter-defibrillator
    Yang, Pil-Sung
    Kang, Younghyun
    Bae, Han-Joon
    Sung, Jung-Hoon
    Park, Hyung-Deuk
    Joung, Boyoung
    JOURNAL OF ARRHYTHMIA, 2021, 37 (06) : 1537 - 1545
  • [5] Right Bundle Branch Block Predicts Appropriate Implantable Cardioverter Defibrillator Therapies in Patients with Non-Ischemic Dilated Cardiomyopathy and a Prophylactic Implantable Cardioverter Defibrillator
    Jimenez-Blanco Bravo, Marta
    Salinas, Gonzalo Luis Alonso
    Esteban, Carolina Parra
    Ramos, Jorge Toquero
    Luque, Miguel Amores
    Gomez, Jose Luis Zamorano
    Garcia-Izquierdo, Eusebio
    Alvarez-Garcia, Jesus
    Lozano, Ignacio Fernandez
    Urda, Victor Castro
    DIAGNOSTICS, 2024, 14 (11)
  • [6] Cost-utility analysis of an implantable cardioverter-defibrillator for the treatment of ischemic or non-ischemic NYHA II-III heart failure patients in Colombia
    Atehortua, Sara
    Manuel Senior, Juan
    Castro, Paula
    Ceballos, Mateo
    Saldarriaga, Clara
    Giraldo, Nelson
    Mora, Guillermo
    BIOMEDICA, 2019, 39 (03):
  • [7] Selvester score predicts implantable cardioverter defibrillator shocks in patients with non-ischemic cardiomyopathy
    Arisoy, Fazil
    Ozcan Celebi, Ozlem
    Erbay, Ilke
    Tufekcioglu, Omac
    Aydogdu, Sinan
    Temizhan, Ahmet
    JOURNAL OF ARRHYTHMIA, 2021, 37 (04) : 1046 - 1051
  • [8] The effect of implantable cardioverter-defibrillator in patients with diabetes and non-ischaemic systolic heart failure
    Rorth, Rasmus
    Thune, Jens Jakob
    Nielsen, Jens C.
    Haarbo, Jens
    Videbaek, Lars
    Korup, Eva
    Signorovitch, James
    Bruun, Niels E.
    Eiskjaer, Hans
    Hassager, Christian
    Svendsen, Jesper Hastrup
    Hofsten, Dan E.
    Torp-Pedersen, Christian
    Pehrson, Steen
    Kober, Lars
    Kristensen, Soren L.
    EUROPACE, 2019, 21 (08): : 1203 - 1210
  • [9] Effectiveness of Implantation of Cardioverter-Defibrillators Therapy in Patients with Non-Ischemic Heart Failure: an Updated Systematic Review and Meta-Analysis
    Xing, Zhenhua
    Tang, Liang
    Chen, Chenyang
    Huang, Jiabing
    Zhu, Zhaowei
    Hu, Xinqun
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 32 (05) : 417 - 422
  • [10] Cardiac Dysfunction and Prolonged Hemodynamic Deterioration After Implantable Cardioverter-Defibrillator Shock in Patients With Systolic Heart Failure
    Toh, Norihisa
    Nishii, Nobuhiro
    Nakamura, Kazufumi
    Tada, Takeshi
    Oe, Hiroki
    Nagase, Satoshi
    Kohno, Kunihisa
    Morita, Hiroshi
    Kusano, Kengo F.
    Ito, Hiroshi
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (05): : 898 - 905