Clinical predictors of cardiac syncope in patients with unexplained syncope after the implantation of an insertable cardiac monitor

被引:1
作者
Matsumoto, Kenji [1 ]
Kodama, Yuka [1 ]
Ito, Shinji [1 ]
Nakamura, Yuka [1 ]
Fujiwara, Ryosuke [1 ]
Kajio, Keiko [1 ]
Kasamatsu, Keiko [1 ]
Murata, Eriko [1 ]
Nakamura, Yasuhiro [1 ]
Kawase, Yoshio [1 ]
机构
[1] Izumi City Gen Hosp, Dept Cardiol, 4-5-1 Wake Cho, Izumi 5940073, Japan
关键词
Syncope; Insertable cardiac monitor; Trauma; Brain natriuretic peptide; Arrythmia; NATRIURETIC PEPTIDE LEVELS; LOOP-RECORDER; ATRIAL-FIBRILLATION; PACEMAKER IMPLANTATION; OLDER-ADULTS; GUIDELINE; MECHANISM;
D O I
10.1007/s00380-022-02212-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Syncope prognosis is related to both its etiology and comorbidities, with cardiac syncope (CS) having higher risks for mortality and cardiovascular events than syncope of non-cardiac causes. Although a novel insertable cardiac monitor (ICM) is an effective diagnostic tool for unexplained syncope, decision regarding ICM implantation with a high pre-test likelihood of CS should contribute to economic cost reduction and avoidance of unnecessary complications. This study aimed to investigate clinical factors associated with CS after ICM implantation in patients with unexplained syncope. This retrospective observational study included 31 consecutive patients with ICM implantation for syncope between September 2016 and August 2021. The initial examinations for syncope included a detailed history, physical examination, blood tests, 12-lead electrocardiograms, and transthoracic echocardiography. Of the 31 patients, 13 (41.9%) experienced recurrent CS during follow-up (676 +/- 469 days). Among several clinical factors, syncope-related minor injuries (p = 0.017) and higher brain natriuretic peptide (BNP; p = 0.043) levels were significantly associated with CS. Moreover, multivariable analysis showed that both syncope-related minor injuries (odds ratio, 11.2; 95% confidence interval, 1.4-88.4; p = 0.022) and BNP higher than 64.0 pg/mL (odds ratio, 7.0; 95% confidence interval, 1.1-44.2; p = 0.038) were independent predictors of CS after ICM implantation. In conclusion, a history of minor injury secondary to syncope and higher BNP levels were independent CS predictors in patients receiving ICM for syncope. These results emphasized the utility of ICM implantation early in the diagnostic journey of patients presenting with CS predictors requiring specific treatments.
引用
收藏
页码:731 / 739
页数:9
相关论文
共 39 条
  • [1] Clinical Predictors of Pacemaker Implantation in Patients with Syncope Receiving Implantable Loop Recorder with or without ECG Conduction Abnormalities
    Ahmed, Nauman
    Frontera, Antonio
    Carpenter, Alexander
    Cataldo, Stafenia
    Connolly, Georgia M.
    Fasiolo, Matteo
    Cripps, Tim
    Thomas, Glyn
    Diab, Ihab
    Duncan, Edward R.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (08): : 934 - 941
  • [2] Long-term cardiac monitoring in older adults with unexplained falls and syncope
    Bhangu, Jaspreet
    McMahon, C. Geraldine
    Hall, Patricia
    Bennett, Kathleen
    Rice, Ciara
    Crean, Peter
    Sutton, Richard
    Kenny, Rose-Anne
    [J]. HEART, 2016, 102 (09) : 681 - 686
  • [3] Atrial Fibrillation Catheter Ablation Versus Surgical Ablation Treatment (FAST) A 2-Center Randomized Clinical Trial
    Boersma, Lucas V. A.
    Castella, Manuel
    van Boven, WimJan
    Berruezo, Antonio
    Yilmaz, Alaaddin
    Nadal, Mercedes
    Sandoval, Elena
    Calvo, Naiara
    Brugada, Josep
    Kelder, Johannes
    Wijffels, Maurits
    Mont, Lluis
    [J]. CIRCULATION, 2012, 125 (01) : 23 - 30
  • [4] A new management of syncope: prospective systematic guideline-based evaluation of patients referred urgently to general hospitals
    Brignole, M
    Menozzi, C
    Bartoletti, A
    Giada, F
    Lagi, A
    Ungar, A
    Ponassi, I
    Mussi, C
    Maggi, R
    Re, G
    Furlan, R
    Rovelli, G
    Ponzi, P
    Scivales, A
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 (01) : 76 - 82
  • [5] The usage and diagnostic yield of the implantable loop-recorder in detection of the mechanism of syncope and in guiding effective antiarrhythmic therapy in older people
    Brignole, M
    Menozzi, C
    Magi, R
    Solano, A
    Donateo, P
    Bottoni, N
    Lolli, G
    Quartieri, F
    Croci, F
    Oddone, D
    Puggioni, E
    [J]. EUROPACE, 2005, 7 (03): : 273 - 279
  • [6] 2018 ESC Guidelines for the diagnosis and management of syncope
    Brignole, Michele
    Moya, Angel
    de lange, Frederik J.
    Deharo, Jean-Claude
    Elliott, Perry M.
    Fanciulli, Alessandra
    Fedorowski, Artur
    Furlan, Raffaello
    Kenny, Rose Anne
    Martin, Alfonso
    Probst, Vincent
    Reed, Matthew J.
    Rice, Ciara P.
    Sutton, Richard
    Ungar, Andrea
    van Dijk, J. Gert
    [J]. KARDIOLOGIA POLSKA, 2018, 76 (08) : 1119 - 1198
  • [7] Assessment of a standardized algorithm for cardiac pacing in older patients affected by severe unpredictable reflex syncopes
    Brignole, Michele
    Ammirati, Fabrizio
    Arabia, Francesco
    Quartieri, Fabio
    Tomaino, Marco
    Ungar, Andrea
    Lunati, Maurizio
    Russo, Vitantonio
    Del Rosso, Attilio
    Gaggioli, Germano
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 (24) : 1529 - 1535
  • [8] Indications for the use of diagnostic implantable and external ECG loop recorders
    Brignole, Michele
    Vardas, Panos
    Hoffman, Ellen
    Huikuri, Heikki
    Moya, Angel
    Ricci, Renato
    Sulke, Neil
    Wieling, Wouter
    Auricchio, Angelo
    Lip, Gregory Y. H.
    Almendral, Jesus
    Kirchhof, Paulus
    Aliot, Etienne
    Gasparini, Maurizio
    Braunschweig, Frieder
    [J]. EUROPACE, 2009, 11 (05): : 671 - 687
  • [9] Insertable cardiac monitors in the diagnosis of syncope and the detection of atrial fibrillation: A systematic review and meta-analysis
    Burkowitz, Joerg
    Merzenich, Carina
    Grassme, Kathrin
    Brueggenjuergen, Bernd
    [J]. EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2016, 23 (12) : 1261 - 1272
  • [10] Loop recorders for syncope evaluation: what is the evidence?