Trace element analysis in lithium matrices using micro-discharge optical emission spectroscopy

被引:3
作者
Wiggershaus, Bastian [1 ]
Jeskanen, Miisamari [2 ]
Roos, Aappo [2 ]
Vogt, Carla [1 ]
Laurila, Toni [2 ]
机构
[1] TU Bergakad Freiberg, Inst Analyt Chem, Lessingstr 45, D-09599 Freiberg, Germany
[2] Sensmet Oy, Customer Applicat Ctr, Otakaari 7, Espoo 02150, Finland
关键词
ATMOSPHERIC-PRESSURE; VAPOR GENERATION; PLASMA; SPECTROMETRY; CATHODE; HG; SB;
D O I
10.1039/d4ja00044g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The increasing demand for high purity battery elements and the necessity to reliably determine trace concentrations of impurity metals have triggered recent development of new analytical methods. Both in battery metal production and recycling there is a growing need for new fast, precise and easy-to-use analytical methods, especially for the on-line and on-site analysis of lithium salt solutions, whose derivative products are used in the battery industry. Typically used established techniques, such as ICP-OES or ICP-MS, are usually limited to laboratory use due to high plasma gas flow rates and power consumption, making them unsuitable for real-time analysis and monitoring of industrial processes on-site. Therefore, a fast and precise on-site method which allows trace element analysis would be preferable. Here we have investigated the potential of micro-discharge optical emission spectroscopy (mu DOES) for the given challenge of on-line quantification of impurity metals in lithium matrices. The technology is based on a micro-plasma, which is directly created inside an aqueous sample without any carrier gas by using electrodes and high voltage pulses. In this study, the impurity elements Na, K, Al, Fe and Zn were simultaneously measured both in lithium carbonate and lithium hydroxide solutions. For this purpose, the lithium concentrations were varied between 0.3 and 2 mg L-1 and those of the contaminants between 0 and 50 mu g L-1. Calibration series and long-term stability measurements were carried out, whereby various parameters such as the plasma discharge energy, signal integration setting and sample electrical conductivity were optimised. Micro-discharge optical emission spectroscopy proved to be useful for the fast and precise main component and trace analysis of saline solutions. A relative standard deviation of 3% was achieved for the lithium concentration in long-term measurements over 9 h. For the trace impurity metals (Na, K, Al, Fe, and Zn) high coefficients of determination (R-2 > 0.99) and limits of detection in the low mu g L-1-region, comparable to ICP-OES, were obtained. Multi-linear regression models were used to correct for cross-element correlations that may occur at increasing lithium concentrations due to ionisation effects. Industrial process samples were measured on-site and the results were validated using laboratory ICP-OES.
引用
收藏
页码:1248 / 1259
页数:13
相关论文
共 50 条
  • [41] Analysis and control of Hall effect thruster using optical emission spectroscopy and artificial neural network
    Ben Slimane, Tarek
    Leduc, Alexandre
    Schiesko, Loic
    Bourdon, Anne
    Chabert, Pascal
    [J]. JOURNAL OF APPLIED PHYSICS, 2024, 136 (15)
  • [42] Determination of trace amounts of sodium and lithium in zirconium dioxide (ZrO2) using liquid electrode plasma optical emission spectrometry
    Banno, Michiko
    Tamiya, Eiichi
    Takamura, Yuzuru
    [J]. ANALYTICA CHIMICA ACTA, 2009, 634 (02) : 153 - 157
  • [43] Glow discharge optical emission spectroscopy: a complementary technique to analyze thin electrodeposited polyaniline films
    Moutarlier, V.
    Lakard, S.
    Patois, T.
    Lakard, B.
    [J]. THIN SOLID FILMS, 2014, 550 : 27 - 35
  • [44] Trace arsenic analysis in edible seaweeds by miniature in situ dielectric barrier discharge microplasma optical emission spectrometry based on gas phase enrichment
    Zhang, Yaru
    Mao, Xuefei
    Tian, Di
    Liu, Jixin
    Li, Chunsheng
    [J]. ANALYTICAL METHODS, 2021, 13 (36) : 4079 - 4089
  • [45] Ultrasensitive determination of mercury by atmospheric pressure glow discharge optical emission spectroscopy coupled with solution cathode glow discharge microplasma
    Chen, Huixiu
    Wang, Zheng
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (10) : 2185 - 2191
  • [46] A pulsed electrolyte cathode discharge used for metal element analysis by atomic emission spectrometry
    Yuan, Hao
    Yang, De-Zheng
    Li, Xiao
    Zhang, Li
    Zhou, Xiong-Feng
    Wang, Wen-Chun
    Xu, Yong
    [J]. PHYSICS OF PLASMAS, 2019, 26 (05)
  • [47] Plasma diagnostics using optical emission spectroscopy in laser drilling process
    Shin, Joonghan
    Mazumder, J.
    [J]. JOURNAL OF LASER APPLICATIONS, 2016, 28 (02)
  • [48] Miniaturized point discharge-radical optical emission spectrometer: A multichannel optical detector for discriminant analysis of volatile organic sulfur compounds
    Li, Mengtian
    Huang, Shixu
    Xu, Kailai
    Jiang, Xiaoming
    Hou, Xiandeng
    [J]. TALANTA, 2018, 188 : 378 - 384
  • [49] ANALYSIS OF ALLOY LAYERS ON METAL-COATED STEEL WITH GLOW-DISCHARGE OPTICAL-EMISSION SPECTROMETRY
    GOWER, SA
    PAYLING, R
    JONES, DG
    TILDEN, G
    WILLIS, DJ
    [J]. INTERFACES II, 1995, 189- : 417 - 422
  • [50] Performance Evaluation of Atmospheric Pressure Glow Discharge-Optical Emission Spectrometry for the Determination of Sodium, Lithium, Calcium and Magnesium Using Membrane Desolvation
    Dong, Junhang
    Yang, Chun
    He, Dong
    Zheng, Hongtao
    Hu, Shenghong
    Zhu, Zhenli
    [J]. ATOMIC SPECTROSCOPY, 2020, 41 (02) : 57 - 63