Objective: To confirm that the simplified insole does not affect the gait speed and to identify objective sensor-based gait parameters that correlate strongly with existing clinical gait assessment scales. Methods: Ten participants with gait impairment due to hemiplegic stroke were enrolled in this study. Pairs of insoles with four pressure sensors on each side were manufactured and placed in each shoe. Data were extracted during the 10-Meter Walk Test. Several sensor-derived parameters (for example stance time, heel_on-to-toe_peak time, and toe_peak pressure) were calculated and correlated with gait speed and lower extremity Fugl-Meyer (F-M) score. Results: The insole pressure sensor did not affect gait, as indicated by a strong correlation (rho=0.988) and high agreement (ICC=0.924) between the gait speeds with and without the insole. The parameters that correlated most strongly with highest beta coefficients against the clinical measures were stance time of the non-hemiplegic leg (beta=-0.87 with F-M and beta=0.95 with gait speed) and heel_on-to-toe_peak time of the non-hemiplegic leg (beta=-0.86 with F-M and -0.94 with gait speed). Conclusion: Stance time of the non-hemiparetic leg correlates most strongly with clinical measures and can be assessed using a non-obtrusive insole pressure sensor that does not affect gait function. These results suggest that an insole pressure sensor, which is applicable in a home environment, may be useful as a clinical endpoint in post-stroke gait therapy trials.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 50 条
  • [1] Psychometric properties of wearable technologies to assess post-stroke gait parameters: A systematic review
    da Silva, Raiff Simplicio
    da Silva, Stephano Tomaz
    Cardoso, Daiane Carla Rodrigues
    Quirino, Maria Amanda Ferreira
    Silva, Maria Heloiza Araujo
    Gomes, Larissa Araujo
    Fernandes, Jefferson Doolan
    Oliveira, Raul Alexandre Nunes da Silva
    Fernandes, Aline Braga Galva o Silveira
    Ribeiro, Tatiana Souza
    GAIT & POSTURE, 2024, 113 : 543 - 552
  • [2] Utilization of wearable technology to assess gait and mobility post-stroke: a systematic review
    Peters, Denise M.
    O'Brien, Emma S.
    Kamrud, Kira E.
    Roberts, Shawn M.
    Rooney, Talia A.
    Thibodeau, Kristen P.
    Balakrishnan, Swapna
    Gell, Nancy
    Mohapatra, Sambit
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2021, 18 (01)
  • [3] Application of the Gait Deviation Index in the analysis of post-stroke hemiparetic gait
    Guzik, Agnieszka
    Druzbicki, Mariusz
    JOURNAL OF BIOMECHANICS, 2020, 99 (99)
  • [4] Gait characteristics of post-stroke hemiparetic patients with different walking speeds
    Wang, Yiji
    Mukaino, Masahiko
    Ohtsuka, Kei
    Otaka, Yohei
    Tanikawa, Hiroki
    Matsuda, Fumihiro
    Tsuchiyama, Kazuhiro
    Yamada, Junya
    Saitoh, Eiichi
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2020, 43 (01) : 69 - 75
  • [5] Manipulating post-stroke gait: Exploiting aberrant kinematics
    Reissman, Megan E.
    Gordon, Keith E.
    Dhaher, Yasin Y.
    JOURNAL OF BIOMECHANICS, 2018, 67 : 129 - 136
  • [6] Identifying impairments and compensatory strategies for temporal gait asymmetry in post-stroke persons
    Mizuta, Naomichi
    Hasui, Naruhito
    Higa, Yasutaka
    Matsunaga, Ayaka
    Ohnishi, Sora
    Sato, Yuki
    Nakatani, Tomoki
    Taguchi, Junji
    Morioka, Shu
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [7] Effects of ankle-foot orthoses on the stability of post-stroke hemiparetic gait
    Tsuchiyama, Kazuhiro
    Mukaino, Masahiko
    Ohtsuka, Kei
    Matsuda, Fumihiro
    Tanikawa, Hiroki
    Yamada, Junya
    Pongpipatpaiboon, Kannit
    Kanada, Yoshikiyo
    Saitoh, Eiichi
    Otaka, Yohei
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2022, 58 (03) : 352 - 362
  • [8] Robotic Biofeedback for Post-Stroke Gait Rehabilitation: A Scoping Review
    Pinheiro, Cristiana
    Figueiredo, Joana
    Cerqueira, Joao
    Santos, Cristina P.
    SENSORS, 2022, 22 (19)
  • [9] Characteristics of limb kinematics in the gait disorders of post-stroke patients
    Mizuta, Naomichi
    Hasui, Naruhito
    Kai, Takumi
    Inui, Yasuhiro
    Sato, Masahiro
    Ohnishi, Sora
    Taguchi, Junji
    Nakatani, Tomoki
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [10] Effects of hip abduction and adduction accuracy on post-stroke gait
    Dean, Jesse C.
    Embry, Aaron E.
    Stimpson, Katy H.
    Perry, Lindsay A.
    Kautz, Steven A.
    CLINICAL BIOMECHANICS, 2017, 44 : 14 - 20