Validation of Photoplethysmography Using a Mobile Phone Application for the Assessment of Heart Rate Variability in the Context of Heart Rate Variability-Biofeedback

被引:4
作者
van Dijk, Willeke [1 ,6 ]
Huizink, Anja C.
Oosterman, Mirjam [2 ]
Lemmers-Jansen, Imke L. J. [1 ,3 ,4 ]
de Vente, Wieke [5 ]
机构
[1] Vrije Univ Amsterdam, Fac Behav & Movement Sci, Dept Clin Neuro & Dev Psychol, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Fac Behav & Movement Sci, Dept Clin Child & Family Studies, Amsterdam, Netherlands
[3] Inst Brain & Behav Amsterdam IBBA, Amsterdam, Netherlands
[4] Kings Coll London, Inst Psychiat Psychol & Neurosci, London, England
[5] Univ Amsterdam, Res Inst Child Dev & Educ, Amsterdam, Netherlands
[6] Room MF-A529,Boechorststr 7, NL-1081 BT Amsterdam, Netherlands
来源
PSYCHOSOMATIC MEDICINE | 2023年 / 85卷 / 07期
关键词
photoplethysmography; diaphragmatic breathing; heart rate variability; mobile app; validation; electrocardiography; PERFORMANCE; AGREEMENT;
D O I
10.1097/PSY.0000000000001236
中图分类号
R749 [精神病学];
学科分类号
100205 ;
摘要
Objective: Heart rate variability-biofeedback (HRV-BF) is an effective intervention to reduce stress and anxiety and requires accurate measures of real-time HRV. HRV can be measured through photoplethysmography (PPG) using the camera of a mobile phone. No studies have directly compared HRV-BF supported through PPG against classical electrocardiogram (ECG). The current study aimed to validate PPG HRV measurements during HRV-BF against ECG. Methods: Fifty-seven healthy participants (70% women) with a mean (standard deviation) age of 26.70 (9.86) years received HRV-BF in the laboratory. Participants filled out questionnaires and performed five times a 5-minute diaphragmatic breathing exercise at different paces (range, similar to 6.5 to similar to 4.5 breaths/min). Four HRV indices obtained through PPG, using the Happitech software development kit, and ECG, using the validated NeXus apparatus, were calculated and compared: RMSSD, pNN50, LFpower, and HFpower. Resonance frequency (i.e., optimal breathing pace) was also compared between methods. Results: All intraclass correlation coefficient values of the five different breathing paces were "near perfect" (>0.90) for all HRV indices: lnRMSSD, lnpNN50, lnLFpower, and lnHFpower. All Bland-Altman analyses (with just three incidental exceptions) showed good interchangeability of PPG- and ECG-derived HRV indices. No systematic evidence for proportional bias was found for any of the HRV indices. In addition, correspondence in resonance frequency detection was good with 76.6% agreement between PPG and ECG. Conclusions: PPG is a potentially reliable and valid method for the assessment of HRV. PPG is a promising replacement of ECG assessment to measure resonance frequency during HRV-BF.
引用
收藏
页码:568 / 576
页数:9
相关论文
共 50 条
  • [21] Analysis of Heart Rate Variability from Multichannel Photoplethysmography
    Peter, Lukas
    Ladrova, Martina
    Bryjova, Iveta
    Cerny, Martin
    NEW TRENDS IN INTELLIGENT SOFTWARE METHODOLOGIES, TOOLS AND TECHNIQUES, 2017, 297 : 217 - 225
  • [22] Analysis of the Mobile Phone Effect on the Heart Rate Variability by Using the Largest Lyapunov Exponent
    Derya Yılmaz
    Metin Yıldız
    Journal of Medical Systems, 2010, 34 : 1097 - 1103
  • [23] Analysis of the Mobile Phone Effect on the Heart Rate Variability by Using the Largest Lyapunov Exponent
    Yilmaz, Derya
    Yildiz, Metin
    JOURNAL OF MEDICAL SYSTEMS, 2010, 34 (06) : 1097 - 1103
  • [24] The Application of Heart Rate Variability Biofeedback to Medical and Mental Health Disorders
    Moss, Donald
    Shaffer, Fredric
    APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK, 2018, 43 (01) : 105 - 105
  • [25] A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects
    Lu, G.
    Yang, F.
    Taylor, J.A.
    Stein, J.F.
    Journal of Medical Engineering and Technology, 2009, 33 (08) : 634 - 641
  • [26] Impact of Heart Rate Fragmentation on the Assessment of Heart Rate Variability
    Hayano, Junichiro
    Kisohara, Masaya
    Ueda, Norihiro
    Yuda, Emi
    APPLIED SCIENCES-BASEL, 2020, 10 (09):
  • [27] Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions
    Gil, E.
    Orini, M.
    Bailon, R.
    Vergara, J. M.
    Mainardi, L.
    Laguna, P.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (09) : 1271 - 1290
  • [28] A validation study of a smartphone application for heart rate variability assessment in asymptomatic adults
    Gambassi, Bruno Bavaresco
    Neves, Victor Ribeiro
    Alves Brito, Einstein Zeus
    da Silva Fernandes, Danilo Sobral
    Sa, Camila Almeida
    Rocha Nogueira, Raquel Moraes
    Furtado Almeida, Fabiano de Jesus
    de Araujo Cavalcanti, Pedro Augusto
    Gomes Goncalves e Silva, Daniela Conceicao
    Neto, Danilo Sobreira
    de Souza Mesquita, Fabricio Olinda
    Gaspar Novais, Tania Maria
    Matias de Souza, Vania de Fatima
    Cerqueira Oliveira, Antonio Carlos
    Leite, Richard Diego
    Schwingel, Paulo Adriano
    AMERICAN JOURNAL OF CARDIOVASCULAR DISEASE, 2020, 10 (03): : 219 - 229
  • [29] Electrocardiography versus photoplethysmography in assessment of maternal heart rate variability during labor
    Goncalves, Hernani
    Pinto, Paula
    Silva, Manuela
    Ayres-de-Campos, Diogo
    Bernardes, Joao
    SPRINGERPLUS, 2016, 5
  • [30] Comparison of Pulse Rate Variability and Heart Rate Variability for Hypoglycemia Syndrome
    Okkesim, Sukru
    Celik, Gamze
    Yildirim, Mustafa S.
    Ilhan, Mahmut M.
    Karaman, Ozcan
    Tasan, Ertugrul
    Kara, Sadik
    METHODS OF INFORMATION IN MEDICINE, 2016, 55 (03) : 250 - 257