Rational design of a ratiometric fluorescent nanoprobe for real-time imaging of hydroxyl radical and its therapeutic evaluation of diabetes

被引:15
|
作者
Chen, Yiyu [1 ,2 ]
Ji, Xueying [3 ]
Tao, Linlin [1 ,2 ]
Ma, Chao [1 ,2 ]
Nie, Junqi [1 ,2 ]
Lu, Cuifen [1 ,2 ]
Yang, Guichun [1 ,2 ]
Wang, Erfei [1 ,2 ]
Liu, Heng [3 ]
Wang, Feiyi [1 ,2 ]
Ren, Jun [1 ,2 ]
机构
[1] Hubei Univ, Collaborat Innovat Ctr Adv Organ Chem Mat Coconstr, Wuhan 430062, Peoples R China
[2] Hubei Univ, Key Lab Synth & Applicat Organ Funct Mol, Minist Educ, Wuhan 430062, Peoples R China
[3] Hainan Med Univ, Affiliated Hosp 1, Dept Ophthalmol, Haikou 571199, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2024年 / 246卷
基金
海南省自然科学基金; 中国国家自然科学基金;
关键词
Hydroxyl radical; Ratiometric; Nanoprobe; Bioimaging; Diabetes; LIVE CELLS; PROBE; VISUALIZATION; MITOCHONDRIA; SENSOR; LEVEL;
D O I
10.1016/j.bios.2023.115868
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Hydroxyl radical (center dot OH), one of the most reactive and deleterious substances in organisms, belongs to a class of reactive oxygen species (ROS), and it has been verified to play an essential role in numerous pathophysiological scenarios. However, due to its extremely high reactivity and short lifetime, the development of a reliable and robust method for tracking endogenous center dot OH remains an ongoing challenge. In this work, we presented the first ratiometric fluorescent nanoprobe NanoDCQ-3 for center dot OH sensing based on oxidative C-H abstraction of dihydroquinoline to quinoline. The study mainly focused on how to modulate the electronic effects to achieve an ideal ratiometric detection of center dot OH, as well as solving the inherent problem of hydrophilicity of the probe, so that it was more conducive to monitoring center dot OH in living organisms. The screened-out probe NanoDCQ-3 exhibited an exceptional ratiometric sensing capability, better biocompatibility, good cellular uptake, and appropriate in vivo retention, which has been reliably used for detecting exogenous center dot OH concentration fluctuation in living cells and zebrafish models. More importantly, NanoDCQ-3 facilitated visualization of center dot OH and evaluation of drug treatment efficacy in diabetic mice. These findings afforded a promising strategy for designing ratiometric fluorescent probes for center dot OH. NanoDCQ-3 emerged as a valuable tool for the detection of center dot OH in vivo and held potential for drug screening for inflammation-related diseases.
引用
收藏
页数:9
相关论文
共 45 条
  • [1] Design of a New Near-Infrared Ratiometric Fluorescent Nanoprobe for Real-Time Imaging of Superoxide Anions and Hydroxyl Radicals in Live Cells and in Situ Tracing of the Inflammation Process in Vivo
    Liu, Rongjun
    Zhang, Liangliang
    Chen, Yunyun
    Huang, Zirong
    Huang, Yong
    Zhao, Shulin
    ANALYTICAL CHEMISTRY, 2018, 90 (07) : 4452 - 4460
  • [2] Rational design of a ratiometric two-photon fluorescent probe for real-time visualization of apoptosis
    Huang, Yinliang
    Zhou, Qin
    Feng, Yan
    Zhang, Wan
    Fang, Guoshun
    Fang, Min
    Chen, Man
    Xu, Changzhi
    Meng, Xiangming
    CHEMICAL COMMUNICATIONS, 2018, 54 (74) : 10495 - 10498
  • [3] Rational design of near-infrared ratiometric fluorescent probes for real-time tracking of β-galactosidase in vivo
    Chen, Shijun
    Liu, Mengyao
    Zi, Yunjiang
    He, Junyi
    Wang, Lin
    Wu, Yuanyuan
    Hou, Shicong
    Wu, Wenxue
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 285
  • [4] Engineering a "dual-key-and-lock" ratiometric fluorescent nanoprobe for real-time reporting the freshness and quality of meat
    Xiao, Xiao
    Shen, Yizhong
    Cao, Jinxuan
    Sun, Baoguo
    FOOD CHEMISTRY, 2023, 398
  • [5] Activatable NIR-II ratiometric fluorescence nanoprobe for in vivo real-time dynamic imaging of GSH and its-associated diseases
    Bi, Shenghui
    Wen, Xingwang
    Sun, Ge
    Zeng, Songjun
    NANO TODAY, 2023, 53
  • [6] Real-time monitoring of endogenous cysteine levels in living cells using a CD-based ratiometric fluorescent nanoprobe
    Wang, Hong
    Zhang, Peisheng
    Tian, Yong
    Zhang, Yuan
    Yang, Heping
    Chen, Shu
    Zeng, Rongjin
    Long, Yunfei
    Chen, Jian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (18) : 4379 - 4386
  • [7] Real-time monitoring of endogenous cysteine levels in living cells using a CD-based ratiometric fluorescent nanoprobe
    Hong Wang
    Peisheng Zhang
    Yong Tian
    Yuan Zhang
    Heping Yang
    Shu Chen
    Rongjin Zeng
    Yunfei Long
    Jian Chen
    Analytical and Bioanalytical Chemistry, 2018, 410 : 4379 - 4386
  • [8] Rational design of a negative photochromic spiropyran-containing fluorescent polymeric nanoprobe for sulfur dioxide derivative ratiometric detection and cell imaging
    Li, Xiang
    Lin, Zhong
    Tian, Yong
    Zhang, Chonghua
    Zhang, Peisheng
    Zeng, Rongjin
    Qiao, Lei
    Chen, Jian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (04) : 715 - 724
  • [9] Rational design of a negative photochromic spiropyran-containing fluorescent polymeric nanoprobe for sulfur dioxide derivative ratiometric detection and cell imaging
    Xiang Li
    Zhong Lin
    Yong Tian
    Chonghua Zhang
    Peisheng Zhang
    Rongjin Zeng
    Lei Qiao
    Jian Chen
    Analytical and Bioanalytical Chemistry, 2023, 415 : 715 - 724
  • [10] highly selective ratiometric fluorescent probe for real-time imaging of β-glucuronidase in living cells and zebrafish
    Huo, Xiaokui
    Tian, Xiangge
    Li, Yannan
    Feng, Lei
    Cui, Yonglei
    Wang, Chao
    Cui, Jingnan
    Sun, Chengpeng
    Liu, Kexin
    Ma, Xiaochi
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 262 : 508 - 515