Adjustment of Maternal Variable Rate Insulin Infusions Using Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes

被引:3
作者
Avari, Parizad [1 ,2 ]
O'Regan, Alice [1 ]
Preechasuk, Lukana [2 ,3 ]
Oliver, Nick [1 ,2 ]
Agha-Jaffar, Rochan [1 ,2 ]
机构
[1] Imperial Coll Healthcare NHS Trust, Dept Diabet & Endocrinol, London, England
[2] Imperial Coll London, Dept Metab Digest & Reprod, London, England
[3] Mahidol Univ, Fac Med, Siriraj Diabet Ctr Excellence, Siriraj Hosp, Bangkok, Thailand
基金
芬兰科学院;
关键词
Continuous glucose monitoring; Variable rate intravenous insulin infusion; Accuracy; Hypoglycemia;
D O I
10.1089/dia.2022.0507
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Real-time continuous glucose monitoring (CGM) in hospital holds promise; however, further evidence is required on its use to guide adjustment of variable rate intravenous insulin infusion (VRIII). We retrospectively analyzed data from 20 women with type 1 diabetes during the peripartum period who were commenced on VRIII. Data were analyzed for CGM accuracy (Dexcom G6) using point-of-care glucose-CGM matched pairs. The study was entirely observational, with no deviation from standard clinical care. Twenty women were included; median age 30 (26-35) years with first glycated hemoglobin in pregnancy of 57 (49-60) mmol/mol. Overall median absolute relative difference was 6.1 (1.6-17.3)%. The total simulated CGM-adjusted VRIII was 2.5 U per hour, compared with 2.4 U per hour with capillary blood glucose-adjusted VRIII. In this retrospective analysis of CGM adjustment of maternal VRIII, we demonstrate early feasibility and considerable accuracy. Further prospective studies are required to confirm the safety and potential efficacy of CGM-based insulin titration.
引用
收藏
页码:293 / 297
页数:5
相关论文
共 17 条
[1]   Continuous Glucose Monitoring in the Intensive Care Unit During the COVID-19 Pandemic [J].
Agarwal, Shivani ;
Mathew, Justin ;
Davis, Georgia M. ;
Shephardson, Alethea ;
Levine, Ann ;
Louard, Rita ;
Urrutia, Agustina ;
Perez-Guzman, Citlalli ;
Umpierrez, Guillermo E. ;
Peng, Limin ;
Pasquel, Francisco J. .
DIABETES CARE, 2021, 44 (03) :847-849
[2]   Flash Glucose Monitoring Compared to Capillary Glucose Levels in Patients With Diabetic Ketoacidosis: Potential Clinical Applications [J].
Bichard, Lisa K. ;
Rushworth, R. Louise ;
Torpy, David J. .
ENDOCRINE PRACTICE, 2021, 27 (08) :813-818
[3]   Accuracy and Glycemic Efficacy of Continuous Glucose Monitors in Critically Ill COVID-19 Patients: A Retrospective Study [J].
Boeder, Schafer ;
Kobayashi, Emily ;
Ramesh, Gautam ;
Serences, Brittany ;
Kulasa, Kristen ;
Majithia, Amit R. .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (03) :642-648
[4]   Statistical Tools to Analyze Continuous Glucose Monitor Data [J].
Clarke, William ;
Kovatchev, Boris .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 :S45-S54
[5]   Use of Continuous Glucose Monitoring in Non-ICU Hospital Settings for People With Diabetes: A Scoping Review of Emerging Benefits and Issues [J].
Coldron, Benjamin Clubbs ;
Coates, Vivien ;
Khamis, Amjed ;
MacRury, Sandra .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (02) :467-473
[6]   Managing hyperglycaemia during antenatal steroid administration, labour and birth in pregnant women with diabetes - an updated guideline from the Joint British Diabetes Society for Inpatient Care [J].
Dashora, Umesh ;
Levy, Nicholas ;
Dhatariya, Ketan ;
Willer, Nina ;
Castro, Erwin ;
Murphy, Helen R. .
DIABETIC MEDICINE, 2022, 39 (02)
[7]   Accuracy of Dexcom G6 Continuous Glucose Monitoring in Non-Critically Ill Hospitalized Patients With Diabetes [J].
Davis, Georgia M. ;
Spanakis, Elias K. ;
Migdal, Alexandra L. ;
Singh, Lakshmi G. ;
Albury, Bonnie ;
Urrutia, Maria Agustina ;
Zamudio-Coronado, K. Walkiria ;
Scott, William H. ;
Doerfler, Rebecca ;
Lizama, Sergio ;
Satyarengga, Medha ;
Munir, Kashif ;
Galindo, Rodolfo J. ;
Vellanki, Priyathama ;
Cardona, Saumeth ;
Pasquel, Francisco J. ;
Peng, Limin ;
Umpierrez, Guillermo E. .
DIABETES CARE, 2021, 44 (07) :1641-1646
[8]   Glucose as the Fifth Vital Sign: A Randomized Controlled Trial of Continuous Glucose Monitoring in a Non-ICU Hospital Setting [J].
Fortmann, Addie L. ;
Spierling Bagsic, Samantha R. ;
Talavera, Laura ;
Garcia, Isabel Maria ;
Sandoval, Haley ;
Hottinger, Amiry ;
Philis-Tsimikas, Athena .
DIABETES CARE, 2020, 43 (11) :2873-2877
[9]   Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline [J].
Galindo, Rodolfo J. ;
Umpierrez, Guillermo E. ;
Rushakoff, Robert J. ;
Basu, Ananda ;
Lohnes, Suzanne ;
Nichols, James H. ;
Spanakis, Elias K. ;
Espinoza, Juan ;
Palermo, Nadine E. ;
Awadjie, Dessa Garnett ;
Bak, Leigh ;
Buckingham, Bruce ;
Cook, Curtiss B. ;
Freckmann, Guido ;
Heinemann, Lutz ;
Hovorka, Roman ;
Mathioudakis, Nestoras ;
Newman, Tonya ;
O'Neal, David N. ;
Rickert, Michaela ;
Sacks, David B. ;
Seley, Jane Jeffrie ;
Wallia, Amisha ;
Shang, Trisha ;
Zhang, Jennifer Y. ;
Han, Julia ;
Klonoff, David C. .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (06) :1035-1064
[10]   The duration of intrapartum maternal hyperglycaemia predicts neonatal hypoglycaemia in women with pre-existing diabetes [J].
Joshi, T. ;
Oldmeadow, C. ;
Attia, J. ;
Wynne, K. .
DIABETIC MEDICINE, 2017, 34 (05) :725-731