Alignment philosophy influences trochlea recreation in total knee arthroplasty: a comparative study using image-based robotic technology

被引:24
作者
Shatrov, Jobe [1 ,2 ]
Coulin, Benoit [1 ]
Batailler, Cecile [1 ]
Servien, Elvire [1 ]
Walter, Bill [3 ,4 ]
Lustig, Sebastien [1 ]
机构
[1] Lyon Univ Hosp, Croix Rousse Hosp, FIFA Med Ctr Excellence, Orthopaed Surg & Sports Med Dept, Lyon, France
[2] Sydney Orthopaed Res Inst Landmark Orthopaed, Sydney, NSW, Australia
[3] Univ Sydney, Sydney, NSW, Australia
[4] Royal North Shore Hosp, Sydney, NSW, Australia
关键词
Total knee arthroplasty; Trochlea; Patellofemoral; Kinematic alignment; Functional alignment; Mechanical alignment; MALROTATION;
D O I
10.1007/s00264-022-05570-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The ability of kinematic alignment (KA) to consistently restore trochlea anatomy in total knee arthroplasty (TKA) is unknown despite recreation of constitutional anatomy being its rationale for use. The purpose of this study was to assess if alignment choice in TKA effects the ability to restore the native trochlea groove. Methods One hundred and twenty-two consecutive patients undergoing robotic-assisted TKA using the MAKO image-based robotic platform had simulated femoral components placed according to kinematic, mechanical and functional alignment principals. Implant position and trochlea restoration between groups were compared. Restoration was assessed by shift (medial-lateral) and depth relative to the native groove from three consistent points; full extension (0 degrees), mid-flexion (30 degrees-40 degrees) and deep flexion (70 degrees-80 degrees). Results Three hundred and sixty-six alignment options were analysed. Femoral alignment was significantly different between groups. Of KA, 13.1% compared to 3.3% of FA plans were outside safe coronal boundaries. The trochlear groove was translated the most by MA compared to KA and FA (full extension, MA 7.84 +/- 1.99 mm lateral to the native groove, KA 6.40 +/- 2.43 mm and FA 6.88 +/- 1.74 mm, p <= 0.001). In full extension, FA most closely restored the trochlear groove depth in all three positions of flexion. Conclusion Alignment philosophy led to significant differences in trochlea groove recreation. A kinematically placed femoral component led to positioning considered unsafe in over 13% of cases. A functionally placed femoral component most closely restored trochlea depth in all three positions of flexion.
引用
收藏
页码:329 / 341
页数:13
相关论文
共 50 条
  • [41] Increased accuracy in component positioning using an image-less robotic arm system in primary total knee arthroplasty: a retrospective study
    Mancino, Fabio
    Rossi, Stefano Marco Paolo
    Sangaletti, Rudy
    Caredda, Matteo
    Terragnoli, Flavio
    Benazzo, Francesco
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (01) : 393 - 404
  • [42] Comparative Cost Analysis of Robotic-Assisted and Jig-Based Manual Primary Total Knee Arthroplasty
    Cotter, Eric J.
    Wang, Jesse
    Illgen, Richard L.
    JOURNAL OF KNEE SURGERY, 2022, 35 (02) : 176 - 184
  • [43] Accuracies of bone resection, implant position, and limb alignment in robotic-arm-assisted total knee arthroplasty: a prospective single-centre study
    Li, Chenkai
    Zhang, Zian
    Wang, Guanrong
    Rong, Chun
    Zhu, Wanping
    Lu, Xinzhe
    Liu, Yikai
    Zhang, Haining
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [44] Accuracies of bone resection, implant position, and limb alignment in robotic-arm-assisted total knee arthroplasty: a prospective single-centre study
    Chenkai Li
    Zian Zhang
    Guanrong Wang
    Chun Rong
    Wanping Zhu
    Xinzhe Lu
    Yikai Liu
    Haining Zhang
    Journal of Orthopaedic Surgery and Research, 17
  • [45] Imageless robotic-assisted total knee arthroplasty is accurate in vivo: a retrospective study to measure the postoperative bone resection and alignment
    Daniel Schrednitzki
    Christoph Eckhard Horn
    Ute Anne Lampe
    Andreas M. Halder
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3471 - 3479
  • [46] Imageless robotic-assisted total knee arthroplasty is accurate in vivo: a retrospective study to measure the postoperative bone resection and alignment
    Schrednitzki, Daniel
    Horn, Christoph Eckhard
    Lampe, Ute Anne
    Halder, Andreas M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3471 - 3479
  • [47] Time-Based Learning Curve for Robotic-Assisted Total Knee Arthroplasty: A Multicenter Study
    Chen, Zhongming
    Bhowmik-Stoker, Manoshi
    Palmer, Matthew
    Coppolecchia, Andrea
    Harder, Benjamin
    Mont, Michael A.
    Marchand, Robert C.
    JOURNAL OF KNEE SURGERY, 2023, 36 (08) : 873 - 877
  • [48] Achieving functional alignment in total knee arthroplasty: early experience using a second-generation imageless semi-autonomous handheld robotic sculpting system
    Bollars, Peter
    Meshram, Prashant
    Al Thani, Saeed
    Schotanus, Martijn G. M.
    Albelooshi, Ali
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (02) : 585 - 593
  • [49] Residents' Learning Curve of Total Knee Arthroplasty Based on Radiological Outcome Parameters: A Retrospective Comparative Study
    Hoerlesberger, Nina
    Glehr, Mathias
    Amerstorfer, Florian
    Hauer, Georg
    Leithner, Andreas
    Sadoghi, Patrick
    JOURNAL OF ARTHROPLASTY, 2021, 36 (01) : 154 - 159
  • [50] A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery
    Henrica M. J. van der Linden-van der Zwaag
    Janneke Bos
    Huub J. L. van der Heide
    Rob G. H. H. Nelissen
    International Orthopaedics, 2011, 35 : 845 - 850