Alignment philosophy influences trochlea recreation in total knee arthroplasty: a comparative study using image-based robotic technology

被引:24
作者
Shatrov, Jobe [1 ,2 ]
Coulin, Benoit [1 ]
Batailler, Cecile [1 ]
Servien, Elvire [1 ]
Walter, Bill [3 ,4 ]
Lustig, Sebastien [1 ]
机构
[1] Lyon Univ Hosp, Croix Rousse Hosp, FIFA Med Ctr Excellence, Orthopaed Surg & Sports Med Dept, Lyon, France
[2] Sydney Orthopaed Res Inst Landmark Orthopaed, Sydney, NSW, Australia
[3] Univ Sydney, Sydney, NSW, Australia
[4] Royal North Shore Hosp, Sydney, NSW, Australia
关键词
Total knee arthroplasty; Trochlea; Patellofemoral; Kinematic alignment; Functional alignment; Mechanical alignment; MALROTATION;
D O I
10.1007/s00264-022-05570-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The ability of kinematic alignment (KA) to consistently restore trochlea anatomy in total knee arthroplasty (TKA) is unknown despite recreation of constitutional anatomy being its rationale for use. The purpose of this study was to assess if alignment choice in TKA effects the ability to restore the native trochlea groove. Methods One hundred and twenty-two consecutive patients undergoing robotic-assisted TKA using the MAKO image-based robotic platform had simulated femoral components placed according to kinematic, mechanical and functional alignment principals. Implant position and trochlea restoration between groups were compared. Restoration was assessed by shift (medial-lateral) and depth relative to the native groove from three consistent points; full extension (0 degrees), mid-flexion (30 degrees-40 degrees) and deep flexion (70 degrees-80 degrees). Results Three hundred and sixty-six alignment options were analysed. Femoral alignment was significantly different between groups. Of KA, 13.1% compared to 3.3% of FA plans were outside safe coronal boundaries. The trochlear groove was translated the most by MA compared to KA and FA (full extension, MA 7.84 +/- 1.99 mm lateral to the native groove, KA 6.40 +/- 2.43 mm and FA 6.88 +/- 1.74 mm, p <= 0.001). In full extension, FA most closely restored the trochlear groove depth in all three positions of flexion. Conclusion Alignment philosophy led to significant differences in trochlea groove recreation. A kinematically placed femoral component led to positioning considered unsafe in over 13% of cases. A functionally placed femoral component most closely restored trochlea depth in all three positions of flexion.
引用
收藏
页码:329 / 341
页数:13
相关论文
共 50 条
  • [31] Is sequential bilateral robotic total knee arthroplasty a safe procedure? A matched comparative pilot study
    Batailler, Cecile
    Anderson, Mike B.
    Flecher, Xavier
    Ollivier, Matthieu
    Parratte, Sebastien
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (03) : 1599 - 1609
  • [32] A comparative study of the hemodynamic and clinical effects of using or not tourniquet in total knee arthroplasty
    Hung, Shih-Hsin
    Chiu, Fang-Yao
    Cheng, Ming-Fai
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2023, 86 (05) : 529 - 533
  • [33] Slight femoral under-correction versus neutral alignment in total knee arthroplasty with preoperative varus knees: a comparative study
    Kai Lei
    Li-Ming Liu
    Peng-Fei Yang
    Ran Xiong
    De-Jie Fu
    Liu Yang
    Lin Guo
    Arthroplasty, 4
  • [34] HURWA robotic-assisted total knee arthroplasty improves component positioning and alignment - A prospective randomized and multicenter study
    Li, Zheng
    Chen, Xin
    Wang, Xiaoquan
    Zhang, Bo
    Wang, Wei
    Fan, Yu
    Yan, Jun
    Zhang, Xiaofeng
    Zhao, Yu
    Lin, Yuan
    Liu, Jun
    Lin, Jin
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2022, 33 : 31 - 40
  • [35] Custom-fit kinematic alignment in total knee arthroplasty using PSI. The story of ShapeMatch technology
    Calliess, T.
    Ettinger, M.
    Stukenborg-Colsmann, C.
    Windhagen, H.
    ORTHOPADE, 2016, 45 (04): : 314 - +
  • [36] Defining Distinct Stress Curve Morphologies for Coronal Plane Alignment of the Knee Phenotypes Using an Imageless Navigation Robotic Platform in Total Knee Arthroplasty
    Holland, Christopher T.
    Savov, Peter
    Ettinger, Max
    Seyler, Thorsten M.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (10) : 2478 - 2482
  • [37] Accuracy in the Execution of Pre-operative Plan for Limb Alignment and Implant Positioning in Robotic-arm Assisted Total Knee Arthroplasty and Manual Total Knee Arthroplasty: A Prospective Observational Study
    Thilak, Jai
    Babu, Balu C.
    Thadi, Mohan
    Mohan, Vipin
    Kumar, T. Arun
    Mane, Prajwal P.
    Ravindran, Greeshma C.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (04) : 953 - 960
  • [38] Accuracy in the Execution of Pre-operative Plan for Limb Alignment and Implant Positioning in Robotic-arm Assisted Total Knee Arthroplasty and Manual Total Knee Arthroplasty: A Prospective Observational Study
    Jai Thilak
    Balu C. Babu
    Mohan Thadi
    Vipin Mohan
    T. Arun Kumar
    Prajwal P. Mane
    Greeshma C. Ravindran
    Indian Journal of Orthopaedics, 2021, 55 : 953 - 960
  • [39] Comparative analysis of radiation exposure in robot-assisted total knee arthroplasty using popular robotic systems
    Saad, Ahmed
    Mayne, Alistair
    Pagkalos, Joseph
    Ollivier, Matthieu
    Botchu, Rajesh
    Davis, Edward
    Sharma, Akash
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [40] Increased accuracy in component positioning using an image-less robotic arm system in primary total knee arthroplasty: a retrospective study
    Fabio Mancino
    Stefano Marco Paolo Rossi
    Rudy Sangaletti
    Matteo Caredda
    Flavio Terragnoli
    Francesco Benazzo
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 393 - 404