Accuracy of integration of dental cast and cephalograms compared with cone-beam computed tomography: a comparative study

被引:1
|
作者
Dai, Fanfan [1 ,3 ,4 ,5 ]
Chen, Si [2 ,3 ,4 ,5 ]
Feng, Tingting [6 ]
Lu, Wenhsuan [2 ,3 ,4 ,5 ]
Chen, Gui [2 ,3 ,4 ,5 ]
Jiang, Jiuhui [2 ,3 ,4 ,5 ]
Jiang, Ruoping [2 ,3 ,4 ,5 ]
Lin, Jiuxiang [2 ,3 ,4 ,5 ,7 ]
Han, Bing [2 ,3 ,4 ,5 ,7 ]
Xu, Tianmin [2 ,3 ,4 ,5 ]
机构
[1] Peking Univ, Clin Div 2, Sch & Hosp Stomatol, Beijing, Peoples R China
[2] Peking Univ, Dept Orthodont, Sch & Hosp Stomatol, Beijing, Peoples R China
[3] Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[4] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
[5] Beijing Key Lab Digital Stomatol Beijing China, Beijing, Peoples R China
[6] Tongji Univ, Dept Orthodont, Affiliated Stomatol Hosp, Shanghai, Peoples R China
[7] Peking Univ, Craniofacial Growth & Dev Ctr, Beijing, Peoples R China
基金
北京市自然科学基金; 对外科技合作项目(国际科技项目);
关键词
Orthodontic; Dental cast; Cephalograms; Cone-beam computed tomography; Registration; Three dimensional; PALATAL RUGAE; SUPERIMPOSITION; IMPLANT; CHILDREN; SKELETAL; ERUPTION; GROWTH; MOLARS; MODEL;
D O I
10.1007/s10266-022-00732-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study proposes a method that integrates maxillary dental cast and cephalograms and evaluates its accuracy compared with cone-beam computed tomography (CBCT) scans. The study sample comprised 20 adult patients with records of dental casts, cephalograms, and craniofacial CBCT scans. The maxillary dental cast was integrated with lateral and frontal cephalograms based on best-fit registration of palatal and dental outline curves from dental cast with cephalogram tracings. Linear measurement was conducted to assess the intra- and inter-examiner reproducibility of the proposed integration method using intraclass correlation coefficients; linear and angular measurements were conducted to assess its accuracy with CBCT scans as a standard reference. Paired t test, one sample t test, and mean +/- standard deviation of the absolute value of difference were used to compare the integrated images and CBCT. The integration method showed good intra- and inter-examiner reproducibility (intraclass correlation coefficients > 0.98). The differences in linear and angular measurements between the integrated images and CBCT were not statistically significant but with a large deviation. When absolute value of difference was computed, the linear distance error was 0.51 +/- 0.34 mm, the tooth point coordinate errors in X, Y and Z axes were 0.22 +/- 0.22, 0.38 +/- 0.32 and 0.21 +/- 0.21 mm, respectively; the angular error in pitch, roll and yaw of the dental cast was 0.82 +/- 0.51, 0.92 +/- 0.59 and 0.80 +/- 0.41 degree, respectively. The proposed method for integration of dental cast and cephalograms showed good reproducibility and acceptable accuracy compared with CBCT. It could be helpful for researchers to study three-dimensional tooth growth changes using the existing craniofacial growth data especially cephalograms.
引用
收藏
页码:238 / 247
页数:10
相关论文
共 50 条
  • [31] Assessing pulp stones by cone-beam computed tomography
    Nogueira Leal da Silva, Emmanuel Joao
    Prado, Marina C.
    Queiroz, Polyane M.
    Nejaim, Yuri
    Brasil, Danieli M.
    Groppo, Francisco Carlos
    Haiter-Neto, Francisco
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (07) : 2327 - 2333
  • [32] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [33] Postoperative Assessment of Incisor Dental Implants Using Cone-Beam Computed Tomography
    Naitoh, Munetaka
    Nabeshima, Hiromitsu
    Hayashi, Hisashi
    Nakayama, Takehiko
    Kurita, Kenichi
    Ariji, Eiichiro
    JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (05) : 377 - 384
  • [34] Cone-beam computed tomography accuracy in pulp chamber size evaluation: An ex vivo study
    Maddalone, Marcello
    Citterio, Claudio
    Pellegatta, Alberto
    Gagliani, Massimo
    Karanxha, Lorena
    Del Fabbro, Massimo
    AUSTRALIAN ENDODONTIC JOURNAL, 2020, 46 (01) : 88 - 93
  • [35] Accuracy of Cone-Beam Computed Tomography Software in Predicting the Size of Impacted Canine: A Preliminary Study
    Dhanasekaran, Muralidharan
    Faizee, Shahul Hameed
    Rengarajan, Krishnaswamy Nathamuni
    TURKISH JOURNAL OF ORTHODONTICS, 2023, 36 (02) : 111 - 117
  • [36] The Diagnostic Yield of Dental Radiography and Cone-Beam Computed Tomography for the Identification of Dentoalveolar Lesions in Cats
    Heney, Colleen M.
    Arzi, Boaz
    Kass, Philip H.
    Hatcher, David C.
    Verstraete, Frank J. M.
    FRONTIERS IN VETERINARY SCIENCE, 2019, 6
  • [37] Prevalence of Artifacts in Cone-Beam Computed Tomography: A Retrospective Study
    Mahesh, K. P.
    Deshpande, Prasannasrinivas
    Viveka, S.
    JOURNAL OF INDIAN ACADEMY OF ORAL MEDICINE AND RADIOLOGY, 2022, 34 (04) : 428 - 431
  • [38] Cone-Beam Computed Tomography Study of Mandibular Condylar Morphology
    Yalcin, Eda Didem
    Ararat, Emine
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (08) : 2621 - 2624
  • [39] The accuracy of cone-beam computed tomography in assessing maxillary molar furcation involvement
    Qiao, Jing
    Wang, Shiying
    Duan, Jinyu
    Zhang, Yong
    Qiu, Yun
    Sun, Changzhou
    Liu, Denggao
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2014, 41 (03) : 269 - 274
  • [40] An Overview of Cone-Beam Computed Tomography and Dental Panoramic Radiography in Dentistry in the Community
    MacDonald, David
    Telyakova, Vera
    TOMOGRAPHY, 2024, 10 (08) : 1222 - 1237